WIL-11210-E-15
1
WILDEN PUMP & ENGINEERING, LLC
CAUTION: Do not apply compressed air to the
exhaust port — pump will not function.
CAUTION: Do not over-lubricate air supply — excess
lubrication will reduce pump performance. Pump is
pre-lubed.
TEMPERATURE LIMITS:
Polypropylene
0°C to 79°C
32°F to 175°F
PVDF
–12°C to 107°C 10°F to 225°F
PFA
7°C to 107°C 20°F to 225°F
Neoprene
–18°C to 93°C
0°F to 200°F
Buna-N
–12°C to 82°C
10°F to 180°F
EPDM
–51°C to 138°C –60°F to 280°F
Viton
®
FKM
–40°C to 177°C –40°F to 350°F
Wil-Flex™
–40°C to 107°C –40°F to 225°F
Saniflex™
–29°C to 104°C –20°F to 220°F
Polyurethane
–12°C to 66°C
10°F to 150°F
Polytetrafluoroethylene (PTFE)
1
4°C to 104°C 40°F to 220°F
Nylon
–18°C to 93°C
0°F to 200°F
Acetal
–29°C to 82°C –20°F to 180°F
SIPD PTFE with Neoprene-backed 4°C to 104°C 40°F to 220°F
SIPD PTFE with EPDM-backed –10°C to 137°C 14°F to 280°F
Polyethylene
0°C to 70°C
32°F to 158°F
Geolast
®
–40°C to 82°C –40°F to 180°F
NOTE: Not all materials are available for all
models. Refer to Section 2 for material options
for your pump.
CAUTION: When choosing pump materials, be sure to
check the temperature limits for all wetted components.
Example: Viton
®
has a maximum limit of 177°C (350°F)
but polypropylene has a maximum limit of only
79°C (175°F).
CAUTION: Maximum temperature limits are based
upon mechanical stress only. Certain chemicals
will significantly reduce maximum safe operating
temperatures. Consult Chemical Resistance Guide (E4)
for chemical compatibility and temperature limits.
WARNING: Prevent static sparking. If static sparking
occurs, fire or explosion could result. Pump, valves,
and containers must be grounded to a proper
grounding point when handling flammable fluids and
whenever discharge of static electricity is a hazard.
CAUTION: Do not exceed 8.6 bar (125 psig) air supply
pressure.
CAUTION: The process fluid and cleaning fluids
must be chemically compatible with all wetted pump
components. Consult Chemical Resistance Guide (E4).
CAUTION: Do not exceed 82°C (180°F) air inlet
temperature for Pro-Flo X™ models.
CAUTION: Pumps should be thoroughly flushed
before installing into process lines. FDA- and USDA-
approved pumps should be cleaned and/or sanitized
before being used.
CAUTION: Always wear safety glasses when operating
pump. If diaphragm rupture occurs, material being
pumped may be forced out air exhaust.
CAUTION: Before any maintenance or repair is
attempted, the compressed air line to the pump should
be disconnected and all air pressure allowed to bleed
from pump. Disconnect all intake, discharge and air
lines. Drain the pump by turning it upside down and
allowing any fluid to flow into a suitable container.
CAUTION: Blow out air line for 10 to 20 seconds before
attaching to pump to make sure all pipeline debris is
clear. Use an in-line air filter. A 5μ (micron) air filter is
recommended.
NOTE: When installing Teflon
®
diaphragms, it is
important to tighten outer pistons simultaneously
(turning in opposite directions) to ensure tight fit. (See
torque specifications in Section 7.)
NOTE: Cast Iron Teflon
®
-fitted pumps come standard
from the factory with expanded Teflon
®
gaskets
installed in the diaphragm bead of the liquid chamber.
Teflon
®
gaskets cannot be re-used.
NOTE: Before starting disassembly, mark a line from
each liquid chamber to its corresponding air chamber.
This line will assist in proper alignment during
reassembly.
CAUTION: Pro-Flo
®
pumps cannot be used in
submersible applications. Pro-Flo X™ is available
in both submersible and non-submersible options.
Do not use non-submersible Pro-Flo X™ models in
submersible applications. Turbo-Flo
®
pumps can also
be used in submersible applications.
CAUTION: Tighten all hardware prior to installation.
1
4°C to 149°C (40°F to 300°F) - 13 mm (1/2") and 25 mm (1") models only.
S e c t i o n 1
C A U T I O N S — R E A D F I R S T !
Summary of Contents for Wilden Advanced P400
Page 15: ...PX400 M E T A L P X 4 0 0 P E R F O R M A N C E WIL 11210 T 05 ...
Page 41: ...N O T E S ...
Page 52: ...N O T E S ...
Page 53: ...N O T E S ...
Page 54: ...N O T E S ...