8. Operating the Appliance
9.1 The control valve is at the foot on the right-hand side of the
appliance. It has two controls, see Diagram 15:
1. The right-hand knob controls the pilot ignition
2. The left-hand knob controls the main burner
15
9.2 Refer to separate instructions if your appliance is upgraded
to include battery remote control. The instructions below
apply whether or not you have the remote upgrade.
Lighting the Pilot
9.3 To start the left-hand and right-hand control knobs must both
point to off ( ):
9.4 Press in the right-hand control knob and rotate anti-
clockwise until a click is heard. Continue to press in. The
knob points to the pilot ( ).
The pilot is lit
9.5 Keep the knob depressed for 10 seconds before releasing.
The pilot remains lit.
Repeat the above steps if the pilot does not stay lit
NOTE: If the pilot goes out, the Interlock system
prevents you lighting again for a short period
9.6 If, after repeating the above steps the pilot does not light,
contact your Retailer or Installer.
9.7 Turn the right-hand knob to the left to main burner setting
( )
Adjusting the Flame height
9.8 You can now adjust the flame height and temperature using
the left-hand control knob.
9.9 Turn the left-hand knob anti-clockwise to increase the
flame height
9.10 Turn clockwise to decrease the height
IMPORTANT: YELLOW FLAMES TYPICALLY
APPEAR WHEN THE APPLIANCE HAS REACHED
NORMAL OPERATING TEMPERATURE. THIS CAN
TAKE UP TO 30 MINUTES.
WARNING: IF THE APPLIANCE FAILS TO LIGHT OR
BECOMES EXTINGUISHED IN USE, WAIT 3
MINUTES BEFORE ATTEMPTING TO RELIGHT.