5
User Instructions
Adjusting the Flame height
2.8 You can now adjust the flame height and temperature using
the left-hand control knob.
2.9 Turn the left-hand knob anti-clockwise to increase the
flame height.
2.10 Turn clockwise to decrease the height.
IMPORTANT: YELLOW FLAMES TYPICALLY
APPEAR WHEN THE APPLIANCE HAS REACHED
NORMAL OPERATING TEMPERATURE. THIS CAN
TAKE UP TO 30 MINUTES.
WARNING: IF THE APPLIANCE FAILS TO LIGHT OR
BECOMES EXTINGUISHED IN USE, WAIT 3
MINUTES BEFORE ATTEMPTING TO RELIGHT.
3. Turning OFF the Appliance
3.1 To turn the main burner off turn the left-hand knob until it
points to off ( ). Just the pilot remains lit.
3.2 Press in and turn the right-hand knob until it points to off
( ). The pilot goes out.
4. Upgrading the Appliance
4.1 The appliance is fitted with a control valve that can easily be
upgraded to battery powered remote control.
There are two versions of this control which can be obtained
through your local Dovre stockist.
There is no requirement for this upgrade to be carried out by
an approved Gas engineer. However Dovre recommend that
this task is undertaken by a suitably competent person.
4.2 This upgrade can be fitted before or after installation but if
side clearances are limited then it will be easier to upgrade
the appliance before installation. Full instructions are
included with the kit.
Standard Remote Control
(PART NUMBER 8455)
4.3 This remote control can control the gas appliance after
the pilot has been lit. It can turn the main burner on and
regulate it from low through to high and back again.
It can turn the main burner off leaving the pilot burning.
Thermostatic and Timer Remote Control
(PART NUMBER 8456)
4.4 This remote control can control the gas appliance after the
pilot has been lit.
MANUAL MODE
Can be used to turn the main burner on and manually
regulate it from low through to high and back again. It can
also be used to turn the main burner off leaving the pilot
burning.
AUTO MODE
Will automatically regulate the room to a pre-set temperature.
TIMER MODE
Will turn the appliance on and off according to a pre-set
programme and automatically regulate the room temperature
during the two on periods.
5. Cleaning the Appliance
WARNING: NEVER CLEAN THE APPLIANCE
WHILE IT’S HOT. THE APPLIANCE STAYS HOT
FOR A LONG TIME AFTER SHUTDOWN.
IMPORTANT: THE OUTER PANELLING OF THE
APPLIANCE IS MADE FROM CAST IRON. USE
CAUTION WHEN INSTALLING, REMOVING AND
STORING AS THE COMPONENTS ARE HEAVY
AND SHOULD BE HANDLED CAREFULLY.
5.1 Make sure the appliance and surrounds are cool before
cleaning.
REMOVING THE DOOR
5.2 For rear flue exit lift the top of the appliance off and put to
one side.
5.3 For top flue exit lift and support the top to give clearance,
see Diagram 2.
2
5.4 Lift the front upwards until it is clear of the slots and pull
away from the appliance, see Diagram 3.
3