Temp Set (80°F - 104°F / 26°C - 40°C)
The start-up temperature is set at 100°F/37.5°C. The
last measured temperature is constantly displayed on
the LCD.
Note that the last measured spa temperature
displayed
is current only when the pump has been running
for at least 2 minutes.
Press the “Temp” button to display the temperature
previously set. This set temperature is flashed on the
display. Pressing the “Temp” button a second time,
while it is still flashing, will cause the set temperature
to increase or decrease depending on which direction
was last chosen. Each press to follow will change the
set temperature in the same direction. If the opposite
direction is desired, release the pad and let the display
revert to the actual water temperature. Press the button
to display the set temperature and again to make the
temperature change in the desired direction.
Jets
Touch the “Jets” button once to activate the low speed
of the pump and again for the high speed. Press the
“Jets” button again to turn off the pump. If left
running, the pump’s low speed will automatically turn
off after 4 hours, and the pump’s high speed will
automatically turn off after 15 minutes. The low speed
pump may also activate for at least 2 minutes every 30
minutes to detect the spa temperature and then to heat,
to the set temperature if needed, depending upon mode.
When the low speed turns on automatically, it cannot
be deactivated from the panel; however the high speed
may be started.
Light
Press the “Light” button to turn the light on and off. If
left on, the light automatically turns off after 4 hours.
Mode
Mode is changed by pressing the “Temp” button, then
pressing the “Light“ button.
Standard Mode
is programmed to maintain the
desired
temperature. Note that the last measured spa
temperature displayed is current only when the pump
has been running for at least 2 minutes. “St” will be
display momentarily when you switch into Standard
Mode.
Economy Mode
heats the spa to set temperature only
during filter cycles. “Ec” will display solid when
temperature is not current, and will alternate with
temperature when temperature is current.
Sleep Mode
heats the spa to within 20°F of the set
temperature only during filter cycles. The “SL” will
display solid when temperature is not current and will
alternate with temperature when temperature is current.
Preset Filter Cycles
The first filter cycle begins 6 minutes after the spa is
energized. The second filter cycle begins 12 hours
later.
Filter duration is programmable at the Master Control
Pad for 2, 4, 6, 8 hours or for continuous filtration.
(Indicated by “FC”). The default filter time is 2 hours.
To program, press “Temp”, then “Jets”. Press “Temp”
to adjust. Press “Jets” to exit programming.
The low speed of the pump runs during filtration and
the ozone generator (if installed) will be enabled.
Freeze Protection
If the temperature sensors detect a drop below 40° F
within the heater, then the pump (as well as the heater,
if necessary) will automatically activate to provide
freeze protection. The equipment stays on until the
sensors detect that the spa temperature has risen to
within 15° F of the set temperature.