____________________________________________________________________________________________
__________________________________________________________________________________________
22
LCD
LCD
LCD
LCD
ERROR
ERROR
ERROR
ERROR
INDICATOR
INDICATOR
INDICATOR
INDICATOR
Your LCD will readout the following if any problems are detected:
MESSAGE
MEANING
ACTION REQUIRED
No message on display.
The control panel will be disabled until
Power has been cut off to
power returns. Spa settings will be
the spa
preserved until next power up.
- -
Temperature unknown.
After the pump has been running for 2
minutes, the temperature will be displayed.
HH
“Overheat” – The Spa has
DO NOT ENTER THE WATER.
shut down. One of the
Remove the spa cover and allow water to
sensors has detected 118
°
F cool. Once the heater has cooled, reset by
at the heater.
Pushing any button. If spa does not reset,
shut off the power to the spa and call your
dealer or service organization.
OH
“Overheat” – The Spa has
DO NOT ENTER THE WATER.
shut down. One of the
Remove the spa cover and allow water to
sensors has detected 110
°
F. cool. At 107
°
F, the spa should
automatically reset. If spa does not reset,
shut off the power to the spa and call your
dealer or service organization.
IC
“Ice” – Auxiliary Freeze
No action required. The pump will
Potential freeze condition
automatically activate regardless of spa
detected.
status.
SA
Spa is shut down. The
If the problem persists, contact your dealer
sensor that is plugged
or service organization. (May appear
into the Sensor “A” jack
temporarily in an overheat situation and
is not working.
disappear when the heater cools.)
Sb
Spa is shut down. The
If the problem persists, contact your dealer
sensor that is plugged
or service organization. (May appear
into the Sensor “B” jack
temporarily in an overheat situation and
is not working.
disappear when the heater cools.)
Sn
Sensors are out of balance. If the problem persists, contact your dealer
If alternating with spa
or service organization.
temperature, it may just be
a temporary condition. If
flashing by itself, spa is shut
down.