Rainfall Instrument 

-Medallion & Classic Series- 

The rain collector sends a signal to the rainfall meter of .01 inch of 
rain for every 'tip' of the rain mechanism located inside the rain 
collector. There is no need to empty the rain bucket as it is self-
emptying. Freezing weather will not damage the collector, however 
the readings will be inaccurate. Every few months, clean the 
strainer of leaves and other debris to keep the readings accurate. 
 
BOX CONTENTS: 
1 - Rainfall Instrument 
1 - Rain collector, self-tipping with 60' of wire 
1 - 6Volt AC Power Supply

 

 

TO INSTALL: 
1-Place the collector on the base, line up the screw holes and 
tighten until snug. *DON'T OVER TIGHTEN* 
2-Remove the shipping tape from the screen 
3-Mount the collector on a flat, level surface in an open area with 
NO over-hanging obstructions 
4-Mount the bucket base using the 4 screws provided 
5-Run the wire from the bucket to the location of the Rainfall 
Instrument. 
6-Run the wire through a conduit if it needs to go underground 
7-At the rear of the instrument, connect a new 9Volt battery to the 
two terminals at the TOP 
8-Connect the wire from the rain collector to the two terminals on 
the BOTTOM LEFT 
9- (Optional) Connect the 6Volt AC power supply wires to the 
terminals on the BOTTOM RIGHT. During a power outage the 
instrument will switch to battery back up and run off the 9Volt 
battery for about 48 Hours before losing its memory. 

 

INSTRUMENT IS FACTORY CALIBRATED: ALTERING IT 

IN ANY WAY WILL VOID YOUR WARRANTY 

TO OPERATE: 
The LEFT button (as you face the instrument) switches the reading 
from CURRENT to ANNUAL. 
The RIGHT button the RESET button. 
Push and hold for 5 seconds to reset the CURRENT or ANNUAL 
reading, and the digital display will start again at 0. 

 

Be sure the instrument is showing the reading you want to reset 
BEFORE you push and hold the Reset button! If you want to clear 
the 'Current' memory, make sure the instrument is showing the 
'Current' reading and the 'Current' light is on, THEN push and hold 
the RESET button. You don’t want to clear the wrong reading, you 
can't get it back! 

 

Please call with any questions regarding installation or operation of 

this instrument. 

 