WATLOW PROGRAMMING
The Watlow temperature control can record 12 different menus. It must be programmed before use.
It will save its programs in case of power failure.
Each menu includes 3 "STEPS" and each step includes :
Symbol
•
temperature
SP
•
time
t
•
"EVENT"
E
(steam 0001, auto steam 0100, buzzer 0010 or
no event 0000)
To access the programming mode :
•
Press both arrows simultaneously for 5 seconds. Both lights light up to show that the
programming mode is working.
•
Unlock the read only mode (if necessary), press 12 and "CLOCK", LOC appears. Use the arrows
to get 0 and press "CLOCK" again. (To put back on read only mode, you have to have 1 before
pressing on "CLOCK".)
EXAMPLE 1 (preheat program)
-
For menu #1, we will program it so that we have a preheat time of 20 minutes at 400
°
F followed
by a 15 seconds buzzer.
Step #1
•
Press both arrows simultaneously for 5 seconds. Both lights light up to show that the
programming mode is working.
•
Select the program number (Ex : #1)
Suggested values
SP1 appears.
Use the arrows to adjust to the desired temperature
(400°F)
Press on the number of the menu to confirm
(ex. # 1)
t1 appears
Use the arrows to select the desired timing
(20:00)
Press on the number of the menu to confirm
(ex. # 1)
E1 appears
Use the arrows to select the appropriate code
(0000 for no event)
Press on the number of the menu to confirm
(ex. # 1)
Summary of Contents for JA12SLG
Page 24: ...SECTION B DIMENSIONS ...
Page 26: ...B2 16 3 4 22 43 ENTRÉE DE GAZ 1 2 GAS INLET 1 2 JA6SLG JA6SLG ...
Page 27: ...B3 28 5 ENTRÉE D EAU 1 4 WATER INLET 1 4 ENTRÉE ÉLECTRIQUE ELECTRICAL INLET JA6SLG JA6SLG ...
Page 29: ...B5 54 3 4 22 43 ENTRÉE DE GAZ 1 2 GAS INLET 1 2 JA6SLSCG JA6SLSCG ...
Page 32: ...B8 43 22 54 3 4 ENTRÉE DE GAZ 1 2 GAS INLET 1 2 JAOP6SLG JAOP6SLG ...
Page 35: ...B11 43 22 54 3 4 ENTRÉE DE GAZ 1 2 GAZ INLET 1 2 JA12SLG JA12SLG ...
Page 36: ...B12 11 66 ENTRÉE ÉLECTRIQUE ELECTRICAL INLET ENTRÉE D EAU 1 4 WATER INLET 1 4 JA12SLG JA12SLG ...
Page 38: ...B14 43 22 54 3 4 ENTRÉE DE GAZ 1 2 GAS INLET 1 2 JAP12SLG JAOP12SLG ...
Page 40: ...SECTION C BURNER ADJUSTMENTS ...
Page 43: ...SECTION E COMPONENT PARTS ...
Page 44: ...E1 BAKING TIMER THERMOSTAT BAKING TIMER THERMOSTAT 1 2 3 19 18 17 10 16 15 JAP12SLG JAOP12SLG ...
Page 46: ...E3 5 1 2 4 3 JAP12SLG JAOP12SLG ...
Page 48: ...E5 1 2 9 10 3 4 5 6 7 8 H3 H1 H2 H4 X2 X4 X3 X1 JAP12SLG JAOP12SLG ...
Page 52: ...E9 5 AMPS 5 AMPS 1 2 5 6 7 8 9 10 11 JA12SLG JA12SLG ...
Page 54: ...SECTION F CONTROL PANELS ...
Page 73: ...SECTION G ELECTRIC SCHEMATICS ...