DPtech FW1000 Series Firewall Products User Configuration Guide
2-14
Item
Description
Mainboard temperature threshold
Set the lower limit and upper limit of the mainboard temperature threshold.
To configure system thresholds of the device, you can take the following steps:
Select
Device Information Settings
tab.
Enter the threshold in the corresponding place.
After you click
Ok
button, new settings take effect immediately.
Enable remote diagnostic allows users to do non-local operations for the device, which effectively solve the network
failure.
To enter the device information settings page and enable the remote diagnostics function, you can choose
Basic >
System management >Device management > Information settings
from navigation tree, as shown in Figure2-8.
Figure2-8
Enable remote diagnostics
The set frame gap allows user to set the frame gap of data frames.
To enter the device information settings page and set frame gap, you can choose
Basic > System
management >Device management > Information settings
from navigation tree, as shown in Figure2-9.
Figure2-9
Set frame gap
!
Caution:
Please configure the system threshold according to hardware specification and processing capacity. If there is no
special requirement, you should adopt default settings. When hardware utilization, CPU and mainboard
temperature beyond thresholds, the hardware LED on Device Status page will turn red from green. Please contact
network administrator to solve the problem.
2.2.3.2 System parameter
System parameter is mainly set the fast forwarding parameter setting, blacklist taking effect immediately setting,
packet filtering taking effect immediately setting, and Ac Memory Spec Set setting.