background image

 

DPtech LSW5003 Series Industrial Ethernet Switch Installation Manual

 

 

Chapter 2Installation     

10 

 

Figure1-8

 

Optical module diagram 

1.5  Product component 

1.5.1    Service module(LSW-8FET-E) 

The service module (LSW-8FET-E) provides 8*Fast Ethernet interfaces (RJ45). 

 

Figure1-9

 

The service module (LSW-8FET-E) appearance 

1.5.2    Service module (LSW-8FEL-E) 

The service module (LSW-8FEL-E) provides 8*Fast Ethernet optical interfaces (LC). 

 

 

 

Summary of Contents for LSW5003 Series

Page 1: ...DPtech LSW5003 Series Industrial Ethernet Switch Installation Manual i DPtech LSW5003 Series Industrial Ethernet Switch Installation Manual ...

Page 2: ...Ltd provides full range technical support If you need any help please contact Hangzhou DPtech Technologies Co Ltd and its sale agent according to where you purchase their products Hangzhou DPtech Technologies Co Ltd Address 6th floor zhongcai mansion 68 tonghelu Binjiangqu Hangzhoushi Address code 310051 ...

Page 3: ...transmitted by any means Owing to product upgrading or other reasons information in this manual is subject to change Hangzhou DPtech Technology Co Ltd has the right to modify the content in this manual as it is a user guides Hangzhou DPtech Technology Co Ltd made every effort in the preparation of this document to ensure accuracy of the contents but all statements information and recommendations i...

Page 4: ... 3 SERVICE MODULE LSW 6FES E 11 1 5 4 SERVICE MODULE LSW 8FEP E 11 1 5 5 SERVICE MODULE LSW 6FEST E 12 CHAPTER 2 PREPARING FOR INSTALLATION 14 2 1 GENERAL SAFETY RECOMMENDATIONS 14 2 2 EXAMINING THE INSTALLATION SITE 14 2 2 1 TEMPERATURE AND HUMIDITY REQUIREMENT 14 2 2 2 CLEANLINESS 15 2 2 3 ESD REQUIREMENT 15 2 2 4 ANTI INTERFERENCE REQUIREMENT 16 2 2 5 LIGHTNING PROTECTION 16 2 2 6 GROUNDING REQ...

Page 5: ...HERNET MANAGEMENT PORT 8 3 6 2 CONNECTING SERVICE PORT 9 3 7 VERIFY THE INSTALLATION 9 3 8 POWER ON THE SWITCH 9 CHAPTER 4 STARTING UP THE SWITCH AND UPGRADING SOFTWARE 1 4 1 STARTING UP THE SWITCH AT THE INITIAL BOOT 1 4 1 1 SETTING UP A CONFIGURATION ENVIRONMENT 1 4 1 2 BOOTING THE SWITCH 4 4 1 3 STARTING PROCEDURE 5 4 2 DEFAULT LOGIN METHOD FOR WEB 6 CHAPTER 5 MAINTENANCE AND TROUBLESHOOTING 1 ...

Page 6: ...e 11 Figure1 12 The service module LSW 8FEP E appearance 12 Figure1 13 The service module LSW 6FEST E appearance 13 Figure3 1 Switch installation procedure 2 Figure3 2 Mounting device on the workbench 4 Figure3 3 Mounting ear 4 Figure3 4 Mounting the device to a rack To see the image clearly we only snapshot the device 4 Figure3 5 Fasten the switch 5 Figure3 6 Diagram for connecting grounding wire...

Page 7: ...able 1 Table1 2 Console port attribute table 5 Table1 3 Ethernet electrical interface properties 5 Table1 4 SFP Ethernet optical interface attributes 7 Table2 1 Temperature humidity requirement 15 Table2 2 Dust limit in the equipment room 15 Table2 3 Limit of harmful gases in the equipment room 15 Table4 1 Configure serial port properties 3 ...

Page 8: ...ort can enlarge the application range of the product In the meanwhile this kind of product adopts fan less design and uses natural wind to dissipate heat which can save more energy and achieve environment protection 1 2 Introduction of product model and specifications Table1 1 LSW5003 series Ethernet switch specification table Item LSW5003 4GP I R Dimension size W D H 440 360 44mm Weight 5 1Kg Man...

Page 9: ...densation 0 95 1 3 The front view introduction 1 3 1 LSW5003 4GP I R 1 Front view Figure1 1 LSW5003 4GP I R front view 1 Slot SLOT3 interface indicator light 0 2 Slot SLOT2 interface indicator light 0 3 Slot SLOT1 interface indicator light 0 4 Console configuration port 5 The power indicator PWR0 6 Power indicator PWR1 7 Warning indicator light ALM 8 Running indicator light RUN 9 4GE indicator 0 ...

Page 10: ...cates that slot SLOT3 interface 0 is in a non connected state 2 Slot SLOT1 interface indicator light 0 green On Indicates that slot SLOT2 interface 0 is in communication state Blinking Indicates slot SLOT2 interface 0 is sending and receiving data Off Indicates that slot SLOT2 interface 0 is in a non connected state 3 Slot SLOT0 interface indicator light 0 green On Indicates that slot SLOT1 interf...

Page 11: ...ing 8 Hz Indicates that the system is abnormal Off Indicates that the system does not have any alarm 8 Running indicator light RUN green Off Indicates that the system is not started On Indicates that the system is normal and is in the master state Blinking 1 Hz Indicates that the system is normal and is in the standby state Blinking 8 Hz Indicates that the system is starting 9 4GE indicator 0 gree...

Page 12: ...n in Table 1 2 Table1 2 Console port attribute table Attribute Description Connector Type RJ45 Interface standard RS232 Baud rate 9600bps 115200bps default is 9600bps Transmission distance 15m Support services Connected to a character terminal Connect to the local PC serial port and run the terminal emulator on the PC Command line interface 1 4 2 Fast Ethernet electrical interface 1 Ethernet elect...

Page 13: ...able Figure1 4 RJ45 pinout diagram 3 Ethernet cable Ethernet electric interface adopt 5 categories twisted pair cable to connect Ethernet as shown in Figure1 5 Figure1 5 Ethernet cable diagram For different usage Ethernet twisted pair cables can be divided into straight through and crossover cables Standard cable is also called straight through cable The sequences of the twisted pairs crimped in t...

Page 14: ...rface module Long haul 1310nm light interface module Min 9dBm 9dBm 9 5dBm 15dBm 5dBm Max 2 5dBm 3dBm 3dBm 8dBm 0dBm RX Sensitivity 18dBm 20dBm 19dBm 28dBm 34dBm Central wavelength 850nm 1310nm 1310nm 1310nm 1310nm fiber type 62 5 125 μ m multi mode fiber 9 125 μ m single mode fiber 9 125 μ m single mode optical fiber 9 125 μ m single mode optical fiber 9 125 μ m single mode optical fiber Maximum t...

Page 15: ...ctor is a passive component that connects two or more fiber cable segments stably but not permanently Fiber connectors are indispensable to an optical communication system making it possible to connect and disconnect optical channels Either convenient for user to debug and maintain optical system or allow user to adjust optical system more flexible Following are several fiber connector types LC A ...

Page 16: ...tter optical power isn t beyond the upper limit of the optical module Otherwise it may damage optical module 3 Ethernet optical interface fiber For 1000M Ethernet optical interface you can select single mode or multi mode optical fiber to connect Ethernet and according to 1000M Small Form factor Pluggable 1G SFP to select optical fiber These kinds of SPF interfaces are LC fiber connector requiring...

Page 17: ...ptical module diagram 1 5 Product component 1 5 1 Service module LSW 8FET E The service module LSW 8FET E provides 8 Fast Ethernet interfaces RJ45 Figure1 9 The service module LSW 8FET E appearance 1 5 2 Service module LSW 8FEL E The service module LSW 8FEL E provides 8 Fast Ethernet optical interfaces LC ...

Page 18: ...e service module LSW 8FEL E appearance 1 5 3 Service module LSW 6FES E The service module LSW 6FES E provides 6 Fast Ethernet optical interfaces SC Figure1 11 The service module LSW 6FES E appearance 1 5 4 Service module LSW 8FEP E The service module LSW 8FEP E provides 8 Fast Ethernet optical interfaces SFP ...

Page 19: ...trial Ethernet Switch Installation Manual Chapter 2Installation 12 Figure1 12 The service module LSW 8FEP E appearance 1 5 5 Service Module LSW 6FEST E The service module LSW 6FEST E provides 6 Fast Ethernet optical interfaces ST ...

Page 20: ...DPtech LSW5003 Series Industrial Ethernet Switch Installation Manual Chapter 2Installation 13 Figure1 13 The service module LSW 6FEST E appearance ...

Page 21: ...sipation system Ensure that the equipment cabinet and work bench fastness enough which can support device and installation accessory Ensure that the equipment cabinet and work bench well connected ground To ensure your switch normally work and the working life extended installation site should meet following requirement 2 2 1 Temperature and humidity requirement The equipment room must maintain ad...

Page 22: ...t as well The contents of the dust must be limited to the values shown in Table 2 2 Table2 2 Dust limit in the equipment room Substance Unit Content Dust Particles m 3 104 No visible dust on the table top for three days Note Diameter of a dust particle 5 μm Besides the dust there are rigorous limits on the harmful gases that can accelerate the erosion and aging of metals such as salts acids and su...

Page 23: ...ire you using interface cable indoors not use it outdoors to prevent overvoltage and over electricity damaging the device by thunder 2 2 5 Lightning protection Although the switch is designed to be lightning resistant your device can get damaged when excessive lightning is present To protect your device against lightning Ensure the chassis is connected to the earth ground Ensure the ground point o...

Page 24: ...es Warning Never look into the optical ports that are connected to the laser It can harm your eyes 2 4 EMC description CISPR22 compliance DPtech LSW5003 series complies with the requirements of CISPR22 for Class A Information Technology Equipment ITE Warning if this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take cor...

Page 25: ...ation Manual Chapter 3 Device Installation 1 Chapter 3 Device Installation 3 1 Installation Preparation You have read Chapter 2 Preparation for Installation carefully The requirements in Chapter 2 are satisfied Before install you should power off your device ...

Page 26: ...minal Verify the installation Power on your switch Toubleshooting Normal Connect the power cord Verify the installation End Start Power off the switch Install switch to a 19 inch rack Mount the switch on a workbench Connect power cable Yes Install slot extension card Yes Install the required extension card Working normally Yes Yes No No Troubleshooting Figure3 1 Switch installation procedure ...

Page 27: ...ll the device on the table Install the device to the 19 inch cabinet 3 3 1 Mounting switch on workbench If a standard 19 inch rack is unavailable you can place the switch on a clean workbench tabletop To prevent any damage observe the following Ensure the table is stable and well grounded Reserve the clearance of 10 cm around the device for adequate ventilation Do not place any heavy stuff on the ...

Page 28: ...e Installation 4 Figure3 2 Mounting device on the workbench 3 3 2 Mounting switch in a 19 inch rack 1 Mounting ear Figure3 3 Mounting ear 2 Mounting the switch in a rack Figure3 4 Mounting the device to a rack To see the image clearly we only snapshot the device 3 Fastening the switch ...

Page 29: ...de grounding row which allow you to connect the switch grounding wire to the equipment cabinet grounding bar or to grounding row 1 Grounding hole 2 Grounding sign 3 OT terminal 4 4 Grounding cable 5 Grounding screw Figure3 6 Diagram for connecting grounding wire Connecting grounding cable method 1 Remove the grounding screw on the rear panel of the switch 2 Attach the OT terminal on the grounding ...

Page 30: ...se and fasten the ground pole on the switch by hexagonal screw You can ground the wire on the floor if you don t have ground row 1 Hexagonal screw 2 Grounding cable 3 Metal wire of the ground cable which stripped insulation rubber 4 Grounding pole 5 Grounding row Figure3 7 Connecting ground cable to the ground row 3 5 Connecting interface cable Schematic diagram of power terminal 1 5 4 3 2 6 1 Fix...

Page 31: ...rm terminal C 9 is disconnected from the NO 8 C 9 closes with NC 10 Event 3 Abnormal operation of device double power failure alarm terminal C 9 is disconnected from NO 8 C 9 closes with NC 10 Warning device such as warning light alarm buzzer warning device 3 5 2 Connecting AC power cable 1 AC power AC power input range 100V 240V AC 50 60Hz 2 Method for connecting AC power cable 1 Ensure that the ...

Page 32: ...he earth and separate cables can suppress electromagnetic interference so as to ensure that the device is in good working condition 2 Please check the voltage value and pin before plugging in the cable of power supply to the device so as to guard against the wrong or reverse connection 3 6 Connecting interface cable 3 6 1 Connecting Ethernet management port 1 Allows you to configure the switch thr...

Page 33: ...ct the RJ45 terminal and then the DB9 terminal 3 6 2 Connecting service port Shielding twisted pair cable ensure electromagnetic compatibility and the service port supports automatic identify crossover or straight through twisted pair cable 3 7 Verify the Installation The ground wire is securely connected Both of console cable and power cord are correctly connected All the interface cables are rou...

Page 34: ...e console port on the switch and connect the DB 9 female connector of the console cable to the serial port on the PC that is used for configuring the switch as shown in Figure4 1 Figure4 1 Network diagram for configuring the device initial boot through console port 2 Setting terminal parameters You should run HyperTerminal program on the terminal PC when you can configure the terminal PC Follow th...

Page 35: ...he Name field and click OK The dialog box as shown in Figure 4 3 displays Select the serial port to be used from the Connect Using drop down menu The serial port must be the same port connected by the console cable Figure4 3 Setting the connection port Setting the connection port Click OK The Port Settings tab shown in Figure 4 4 appears and you can set serial port parameters Set the following par...

Page 36: ...ng software 3 Table4 1 Configure serial port properties Attribute Value Baud rate 9600bps the default Data bits 8 Parity check None Stop bits 1 Flow control None Note To restore the default settings click Restore Defaults Figure4 4 Setting communications parameters Click OK The HyperTerminal dialogue box appears ...

Page 37: ...igure4 5 Hyper Terminal Select File Properties Settings In the Properties dialog box select the Settings tab as shown in Figure 4 6 Select VT100 or Auto detect in the Emulation dropdown menu Click OK Figure4 6 Settings tab 4 1 2 Booting the Switch 1 Verifying installation before power up Before powering up the switch check that ...

Page 38: ...or on the front panel display normally Method start up your device verify whether the indicator light display normally Verify whether terminal PC display normally Method start up your device and on the terminal PC you can view the device initialization information Enter password at the command line and then you can configure DPtech command line 4 1 3 Starting procedure Power up your device you can...

Page 39: ...SW5003 s console Password Note By default the system password is DPTECH 4 2 Default login method for web LSW5003 device support Web management function the default IP address of network management interface 0 is 192 168 0 1 Administrator can use web interface to manage and maintain the LSW device 1 Open your IE browser type the login information On a reachable Web management terminal or PC open an...

Page 40: ...rting up the switch and upgrading software 7 Figure4 7 Web management interface Caution You should not login to the web management interface by using of http or https protocol on the same PC After first time you login to the web management interface modify the default login password ...

Page 41: ...not hot plug power wire Exam the above steps if power indicator light is still not on please contact sale agent to solve the problem 5 2 Device troubleshooting After you power on the switch if the switch operates properly the startup information appears on the console terminal If the console terminal displays nothing or garbled characters use the following methods to troubleshoot the switch 1 No d...

Page 42: ...he configuration 2 Garbled characters on the terminal Trouble phenomenon See the garbled characters on the terminal PC if you power up your switch Trouble shooting Verify the terminal HyperTerminal parameter settings Bits per second is 9600 Data bits is 8 Parity is None stop bits is 1 Flow control is None and Terminal Emulation is VT100 If your configuration is not same with the above parameters r...

Reviews: