DEAR DR. FREI INFRARED  

FOREHEAD THERMOMETER OWNER

Thank you for choosing 

Dr. Frei

 Infrared Forehead Thermometer 

Model MI-200. We are sure that having appraised worthily the 

high quality and reliability of this device you will become a regular 

user of 

Dr. Frei

®

 products. This innovative medical device uses 

advanced infrared (IR) technology to measure temperature of 

the body or object instantly and accurately. Before starting to 

use this device please study the user manual carefully. The user 

manual  offers  all  information  you  need  to  correctly  take  your 

temperature. For all questions concerning this device please 

contact your local distributor or 

Dr. Frei

®

 service center in your 

country.

ON

SCAN

Summary of Contents for MI-200

Page 1: ...dr frei com MODEL MI 200 USER MANUAL d dr frei c INFRARED FOREHEAD THERMOMETER...

Page 2: ......

Page 3: ...INFRARED FOREHEAD THERMOMETER Model MI 200 User Manual 4 15 MI 200 16 28 MI 200 29 41 TERMOMETRU FRONTAL CU INFRARO U TERMO METRU INFRARO U Model MI 200 Manual de utilizare 42 54 EN RU BG RO MD...

Page 4: ...r of Dr Frei products This innovative medical device uses advanced infrared IR technology to measure temperature of the body or object instantly and accurately Before starting to use this device pleas...

Page 5: ...RE YOU BEGIN 7 Cautions and Warnings 7 Device Overview and Display Operation 8 Display Functions 9 INSTRUCTIONS FOR USE 9 Measurement 9 View Previous Readings 9 Switching Between C and F 10 Switching...

Page 6: ...ages Please keep in mind that tempera tures measured in different places even at the same time should not be directly compared Fever indicates that body tem perature is higher than normal This sympto...

Page 7: ...re 6 most recent body temperature results Easy to read LCD with backlight to use in a dark environment Protective probe cap to keep the device clean Can be used for monitoring the temperature of both...

Page 8: ...ter should be placed in the measuring environment for 30 minutes before being used Drastic changes of the measurement envi ronment such as from outdoor high temperature environment to indoor low tempe...

Page 9: ...ill pro cess a self check then the will light up Self check display Step 3 The device is ready for use when the C symbol is blink ing on the display Step 4 Align the thermometer against the forehead c...

Page 10: ...es are fully charged The symbol appears on the display when the power is off and the device shuts off automatically For fur ther use please open the battery cover replace the batteries put the battery...

Page 11: ...ns Ambient tem perature sensor error Repairment required The ambient temperature is changing dramatically Measure in stable envi ronment Thermopile sensor failure Repairment required The ambient tempe...

Page 12: ...mpera ture reading or Lo will appear on the display Wait 30 minutes to ensure the thermal balance of the device The forehead was treated with cold or hot compress The temperature reading is top low or...

Page 13: ...f corro sive gases SYMBOL INFORMATION Symbol Meaning Consult instructions for use Manufacturer Serial number Caution consult accompanying documents 0123 E Mark Authorized representative in the Europea...

Page 14: ...Operating temperature range 5 C to 40 C Operating humidity 85 RH Atmospheric pressure 70 106 kPa Storage temperature range 25 C to 60 C 13 F 140 F Storage humidity 85 RH Memory capacity 6 measurement...

Page 15: ...by the seller or by the service center representative with the date of the purchase repair the check instructions manual and safe packaging of the device The warranty does not apply to worn out batter...

Page 16: ...16 DR FREI Dr Frei MI 200 Dr Frei Dr Frei ON SCAN...

Page 17: ...RU 17 18 18 MI 200 19 19 20 20 20 21 21 21 22 C F 22 22 22 23 25 25 26 26 27 28...

Page 18: ...18 15 3 0 2 36 4 C 38 C 3 10 36 1 C 37 8 C 11 65 35 9 C 37 6 C 65 35 8 C 37 7 C 35 8 C 38 C 35 5 C 37 5 C 34 5 C 38 C...

Page 19: ...RU 19 34 7 C 37 3 C 36 6 C 38 C MI 200 6 1 2 100 3...

Page 20: ...20 1 2 3 4 5 5 C 40 C 25 C 6 85 7 8 2 5 9 30 10 15 11 12...

Page 21: ...RU 21 ON SCAN 1 35 0 C Lo 44 0 C Hi 2 5 C 40 C ER1 3 2 6 0 2 V 4 30 1 2 ON SCAN...

Page 22: ...22 3 C 4 2 5 ON SCAN 5 C 1 2 C F 1 30 2 ON SCAN ON SCAN C F 3 C F 4 1 2 3 4 ON SCAN...

Page 23: ...RU 23 Dr Frei 1 ON SCAN C 2 ON SCAN 1 ON SCAN C 2 35 C 1 2 2 5 3 4 5 EEPROM...

Page 24: ...24 44 C Lo...

Page 25: ...RU 25 c Lo 2 5 Hi 15 c Lo 30 1 2 3 3...

Page 26: ...26 1 2 3 85 0123 E B...

Page 27: ...RU 27 180x80x47 70 2 AAA 3 0 35 0 C 44 0 C 0 2 C 35 C 42 C 0 3 C 42 C 44 C 0 1 C 0 1 F C or F 5 C 40 C 85 70 106 25 C 60 C 13 F 140 F 85 6 2 2 5 5...

Page 28: ...28 C ASTM E1965 98 EN 12470 5 EN 60601 1 2 2007 AC 2010 EN 60601 1 4 1996 EN 60601 1 6 2010 EN 60601 1 2 93 42 EEC IIa dr frei com 2...

Page 29: ...BG 29 DR FREI Dr Frei MI 200 Dr Frei IR Dr Frei ON SCAN...

Page 30: ...30 31 31 MI 200 32 32 33 33 34 34 34 34 35 C F 35 35 35 36 38 38 39 39 40 41...

Page 31: ...BG 31 15 3 0 2 36 4 C 38 C 3 10 36 1 C 37 8 C 11 65 35 9 C 37 6 C 65 35 8 C 37 7 C...

Page 32: ...32 35 8 C 38 C 35 5 C 37 5 C 34 5 C 38 C 34 7 C 37 3 C 36 6 C 38 C MI 200 6 LCD...

Page 33: ...BG 33 1 2 100 3 1 2 3 4 5 5 C 40 C 25 C 6 85 7 8 2 5 9 30 10 15 11 12...

Page 34: ...34 1 35 0 C Lo 44 0 C Hi 2 5 C 40 C ER1 3 2 6 0 2 V 4 30 1 2 ON SCAN LCD ON SCAN...

Page 35: ...BG 35 3 C 4 2 5 ON SCAN 5 C 1 2 C F 1 30 2 ON SCAN ON SCAN C F 3 C F 4 1 2 3 4 ON SCAN...

Page 36: ...36 Dr Frei 1 ON SCAN C 2 ON SCAN 1 ON SCAN C 2 35 C 1 2 2 5 cm 3 4 5 EEPROM...

Page 37: ...BG 37 44 C Lo...

Page 38: ...38 Lo 2 5 Hi 15 Lo 30 1 2 3 3...

Page 39: ...BG 39 1 2 3 85 0123...

Page 40: ...40 180x80x47 70 2 AAA DC 3 0 V 35 0 C 44 0 C 0 2 C 35 C 42 C 0 3 C 42 C 44 C 0 1 C 0 1 F C F 5 C 40 C 85 70 106 25 C 60 C 13 F 140 F 85 6 2 2 5 cm...

Page 41: ...BG 41 5 ASTM E1965 98 EN 12470 5 EN 60601 1 2 2007 AC 2010 EN 60601 1 4 1996 EN 60601 1 6 2010 EN 60601 1 2 93 42 IIa EMC dr frei com 2...

Page 42: ...dispozitiv medical inovator ncorporeaz cea mai nou teh nologie cu infraro u IR pentru m surarea instantanee i exact a temperatura corpului sau a obiectului V rug m s citi i cu aten ie manualul de util...

Page 43: ...avertismente 46 Prezentare general a dispozitivului i func ionarea ecranului 46 Func iile ecranului 47 INSTRUC IUNI DE UTILIZARE 47 M surare 47 Vizualizare m sur ri anterioare 48 Comutare ntre C i F 4...

Page 44: ...mai jos prezint intervale normale statistice pentru diferite zone de m surare i pentru diferite v rste Trebuie de men ionat c temperatura m surat n diferite zone chiar i n acela i timp nu poate fi co...

Page 45: ...nc ia de stocare n memorie v permite s salva i ultimele 6 m sur tori ale temperaturii corpului Ecran LCD retroiluminat u or de citit pentru utilizare n medii ntunecate Capac de protec ie pentru senzor...

Page 46: ...mai bun rezultat al m sur rii p stra i o distan 2 5 cm 9 Pentru a asigura cel mai bun rezultat al m sur torilor ter mometrul trebuie plasat n mediul de m surare timp de 30 de minute nainte de a fi ut...

Page 47: ...n timpul func ion rii 3 Acest dispozitiv are o func ie de avertizare de joas tensiune nu mai afi eaz valorile dac tensiunea este sub 2 6 0 2 V 4 Dispozitivul se va opri automat la aproximativ 30 de se...

Page 48: ...sa i i ine i ap sat butonul ON SCAN i butonul de memorie n acela i timp apoi elibera i butonul ON SCAN n mo mentul c nd simbolul C F se aprinde intermitent Pasul 3 Ap sa i butonul de memorie i comuta...

Page 49: ...ui 1 Elibera i butonul ON SCAN p n c nd simbolul C va clipi intermitent 2 Butonul ON SCAN nu func ioneaz 1 ine i ap sat butonul ON SCAN p n c nd simbolul C va clipi intermitent 2 Este necesar repa rar...

Page 50: ...LU II Fruntea este acoperit cu p r transpirat etc Pe ecran sunt afi ate valori prea sc zute ale temperaturii sau pictograma Lo Asigura i v c fruntea nu este acoperit cu p r transpirat etc sau m sura i...

Page 51: ...mperatura intern a corpului i tem peratura suprafe ei corpului s ating echilibrul termic DESERVIRE Cur ire i ngrijire 1 Senzorul este partea cea mai precis a dispozitivului trebuie ma nipulat cu preca...

Page 52: ...onformitate cu contractul aferent comenzii 3 Dispozitivul trebuie ambalat i depozitat ntr o nc pere bine ven tilat cu o umiditate relativ care nu dep e te 85 n absen a gazelor corozive INFORMA II DESP...

Page 53: ...0 3 C la 42 C 44 C Rezolu ia ecran ului 0 1 C 0 1 F Unitate de tem peratur C sau F Temperatur de operare 5 C p n la 40 C Umiditate de operare 85 RH Presiunea atmos feric 70 106 kPa Intervalul de temp...

Page 54: ...mai la prezentarea certificatului de garan ie care a fost completat i sigilat corect de c tre v nz tor sau de c tre reprezentantul centrului de service cu nscrierea datei de achizi ie repara iei bonul...

Page 55: ......

Page 56: ...al Equipment Factory No 380 Ningkang East Road Yueqing Zhejiang 325600 People s Republic of China Luxus Lebenswelt GmbH Kochstr 1 47877 Willich Germany medpack group com dr frei com 0123 IB_NCIFT_MI 2...

Reviews: