Do not touch the device if it accidentally falls into the water. Unplug it immediately and do not use afterward. Contact one of authorized service centers.
•
Do not touch the device with wet hands.
•
During use, make sure that the unit is placed on a flat and stable surface.
•
Do not use the device when patient is sleeping.
•
Refer all servicing to the service centre. Do not open the device. If the device does not work properly turn it off and consult the user’s manual.
•
Do not leave any packaging materials (plastic bags, cardboard boxes, and so on) within the reach of children to prevent dangers.
•
Keep accessories out of reach of children. Children and people with reduced physical or mental capacities need to use the device only under close surveillance of an
adult who has read this instruction manual. Keep the medicine cup out of the reach of children under 36 months because it contains small parts that could be ingested.
•
Always disconnect the device from the main socket when it is not used.
•
It is recommended to use one personal medication set of accessories.
•
Do not leave pharmaceutical residual into the medicine cup and/or into the accessories at the end of the therapy.
•
Cleaning and / or maintenance must be done only after turning off the device and unplugged power cord from the outlet.
•
Do not pull cable or appliance in order to remove the plug.
•
This is a medical device for home use and should be used on medical prescription. Must be run as indicated on this user’s instructions. It’s important
that patients read and understand the information for use and maintenance of the unit. Contact your dealer or service centre for any questions.
•
If the equipment’s plug does not fit the socket, contact a qualified technician to substitute the plug. Do not use multiple sockets and/or extensions.
•
Do not obstruct the air intake.
•
The installation must be done according to the instructions and use declared by the manufacturer. Improper installation and / or improper use may
cause damage to persons, animals or things. The manufacturer can not be held responsible.
•
Do not use the device while bathing and showering.
•
Do not expose the device to the action of dust, heat (that could deform the housings), sunlight or other atmospheric agents that could compromise
the safety of the device itself.
•
Do not use the device nearby sources of potential interference (example: heat sources like fireplaces, electric or gas heaters; steam sources like boilers
or kettles, electromagnetic radiation sources like microwave ovens, Wi-Fi devices).
•
Keep away from pets that could contaminate the surface in contact with the patient or in general hinder the right performance of the therapy.
•
The appliance generates compressed air. Secondary consequences could come for the intolerance to the medicine used.
Electric devices must be disposed of in accordance with the locally applicable regulations, not with domestic waste.
KEEP THIS INSTRUCTION MANUAL DURING THE WHOLE SERVICE LIFE OF THE UNIT
Unit Accessories
1
Mouthpiece
2
Adult mask
3
Pediatric mask
4
Medicine cup - upper part
5
Medicine cup - lower part
6
Medicine cup - air entrance
7
Nozzle
8
Air tube
9
Spare air filters (5 pcs)
CARRYING OUT NEBULIZING THERAPY
The appliance is a medical device of class IIa, which converts medicine from the fluid form to vapour in order to adBASEster it directly into the respiratory tracts.
The appliance nebulizes medicines both in suspension and in solution. The therapeutic effect could be reduced with oily and/or pasty medicines.
The appliance is NOT a nebulizer for essential oil. Don’t preheat liquid and/or alcohol solutions. Medicine cup and all accessories have NOT been sterilized.
Read «Unit maintenance» paragraph before use.
Operating the Unit
1. Put the device on a flat, stable surface.
2. Ensure that the rated voltage corresponds to the mains voltage supply.
3. Connect the device into the main socket.
4. Open the medicine cup unscrewing the two parts (figure A).
5. Insert the nozzle in the lower part of the medicine cup (figure B).
6. Fill the medicine cup with pharmaceutical prescribed by your doctor (figure C). Note:
The notches on the lower part of medicine cup are only indicative.
7. Close the medicine cup screwing two parts back (figure D).
8. Connect one end of the air tube (9) to the medication cup and the other end to the
connector on the device (Figure E).
9. Install the needed accessory on the medicine cup: adult or pediatric mask, or mouth
-
piece (figure F).
10. Turn on the device moving the switch to ON position.
11. After the application, turn off the device and unplug. Before restarting the appli
-
ance make sure it has been cooled to room temperature.
9
8
2
3
1
7
4
5
6
2
3
4
5
6
9
8
7
A
B
C
D
E
F
Summary of Contents for TURBO CAR
Page 8: ...8 36...
Page 13: ...UA 13 16 17 I I I 17 i 36...
Page 16: ...16 10 C 40 C 85 860 1060 2 II 2000 5 110 x 110 x 62 2000 8 2460 BF ON OFF IP 21 12...
Page 23: ...BG 23 36 c Wi Fi...
Page 26: ...26 10 C 40 C 85 860 1060 2 II 2000 5 110 x 110 x 62 2000 8 2460 93 42 BF ON OFF IP 21 12...
Page 33: ......