23
Technical data
Type
Lamps in canopy
facial tanner
lamps in bench
Power consumption (W)
Fuse protection (A)
Dimensions L x W x H (mm)
Weight (kg)
24/0
VIVA Fun Power 100 W 2 m 1,0 %
-
VIVA Fun Power 100 W 2 m 1,0 %
2.760
1 x 16
2.160 x 890 x 925
174
24/1
VIVA Fun Power 100 W 2 m 1,0 %
Dr. Kern excellent ER 100 W
HD-Brenner 400 w 230 V - R7S
VIVA Fun Power 100 W 2 m 1,0 %
3.240
1 x 16
2.160 x 890 x 925
178
The lamp in the face tanner becomes very hot during nor-
mal operation and must therefore be cooled with a cooling
fan. The lamp is also fitted with a thermal safety fuse.
If the temperature rises above an acceptable level as a
result of failure of the fan or a fall in power (caused by
soiling or similar) then this fuse breaks the circuit to the
face-tanning lamp.
As this break will only take place as the result of reduced
cooling power the system must be inspected by a
professional or the customer service centre.
The cause of the interruption can also, in very rare cases,
be the fuse itself. This must not normally be changed.
Original parts must be used during all maintenance work.
Do not use the face tanner with a defective filter sheet.
The use with a defective sheet will result in severe
burning of the face.
Subject to technical modifications