4. Mounting instructions 

 

Extent of supply 

• 

1x 5-footed plastic central base 

• 

2x extension arms with blocking rollers 

• 

2x extension arms with electrically conductive rollers 

• 

1x extension arm with roller 

• 

1x cam catch plate 

• 

1x cheese head screw M8 with lock washer 

• 

1x stand tube 

• 

Lamp head with arm 

• 

Mounting instructions/Instructions for use – stand 

• 

Instructions for use – lamp head 

 
 

4.1 Mounting the stand 

 
 
 
 
 

 
 
For mounting the stand proceed as follows: 

• 

Place the central base 

1

 onto the stand tube 

25 

2

. The stiffness is to ensure a tight fit that 

is free from any movement. 

• 

Pre-mount the cam catch plate 

3

 (cams point 

inwards), with the lock washer 

4

 and cheese 

head screw M8 

5

, so that the extension arm 

6

 

can still fit easily into the central base. Insert 
the extension arm 

6

 into the central base from 

above holding the cam catch plate 

3

 against 

from the opposite side. 

• 

Insert the other 4 extension arms 

7-10

 in the 

sequence shown in the left figure into the cen-
tral base. The extension arms are held by the 
cams of the cam catch plates. 

 

Remark: Mount the two locking rollers 11 and 
12, and the two electrically conductive rollers 13 
and 14 as shown in the figure (not next to each 
other). 

 

• 

Tighten the catch plate with an Allen key SW6 
(approx. 15Nm). 
The cams of the catch plate must mate with the 
drill holes of the extension arms so that every 
extension arm is tightly fitted to both the central 
base and stand tube. 
The cams also prevent the extension arms from 
being pulled out. 

14 

10 

12 

13 7 

11 

 

 

Summary of Contents for Stand foot

Page 1: ...Page 1 11 Mounting instructions Directions for use STAND FOOT STAND TUBE Stand lamps Makrolux Mach 115 Mach 120 Mach 120F Dr Mach GmbH u Co Flossmannstrasse 28 D 85560 Ebersberg Tel 49 0 8092 2093 0 Fax 49 0 8092 2093 50 Internet www dr mach com E mail info dr mach de ...

Page 2: ...verview table Page 5 Stand foot stand tube swivel arm 4 Mounting instructions Page 6 4 1 Mounting the stand foot Page 6 5 Directions for use Page 7 5 1 Stand foot Page 7 5 2 Stand tube Page 7 5 3 Swivel arm Page 8 6 Cleaning Page 8 7 Maintenance Page 8 8 Data Page 9 9 Disposal Page 9 10 Spare parts Page 10 10 1 Stand foot Page 10 10 2 Stand tube and swivel arm Page 11 ...

Page 3: ...orrect purposes General information These installation instructions must be kept on the lamp together with the relevant operating instructions for consultation at any time All Dr Mach stand lamps are supplied with all installation and connection parts and compo nents For packaging reasons the five foot stand is supplied in dismantled state The stand tube is always assembled as a unit and only need...

Page 4: ...neering Edition 01 03 02 2000 Bak Page 4 11 2 Installation summary stand lamps Example Lamp Mach 120 The stand is adjustable in heihgt and is to be mounted with the lamps Makrolux Mach 115 and Mach 120 120F The stand is not electrified ...

Page 5: ... optional Secondary 24V Power supply Transformer 20W 39W 40W Number of extension arms 5 Length of extension arm 310mm Stand foot Roller 50mm Length approx 95cm 145cm Diameter 25mm Extension yes Cable connection no Stand tube Suitable for article no 1100 1012 00 1101 1012 00 1151 1012 00 1201 1012 00 1202 2012 00 Swivel arm lamp head Mounting Swivel arm and lamp head premounted Swivel arm to stand ...

Page 6: ...ards with the lock washer 4 and cheese head screw M8 5 so that the extension arm 6 can still fit easily into the central base Insert the extension arm 6 into the central base from above holding the cam catch plate 3 against from the opposite side Insert the other 4 extension arms 7 10 in the sequence shown in the left figure into the cen tral base The extension arms are held by the cams of the cam...

Page 7: ... S on the roller Unlock by lifting the pedal again A S S A 5 2 Stand tube The stand tube can be adjusted continuously in height and fixed in the precisely required position needing only one hand The height is adjusted by lifting the slip button 15 The position is automatically fixed on letting go As long as the slip button 15 is raised the exten sion tube can be pulled off or inserted into the sta...

Page 8: ...he adjusting lever can be brought into a suitable position by pulling it out without changing the ad justed clamping force II I 16 6 Cleaning The surface of the stands can be easily kept clean by simply wiping with a damp cloth You can use conventional cleaning agents In case of disinfection only use disinfectants with less than 20 alcohol Remark For cleaning the lamp head the dis persion lenses a...

Page 9: ... hPa 1060 hPa Transport storage Min Max Temperature 10 C 50 C Relative atmospheric humidity 20 90 Air pressure 700 hPa 1060 hPa 9 Disposal The stands do not contain any danger goods The components of the stand should be properly disposed at the end of its shelf life Make sure that the materials are carefully separated The components of the stand should be disposed according to the contained materi...

Page 10: ...al base 02 1 Stand tube 25mm 03 1 Cam catch plate 04 1 Lock washer 05 1 Cheese head screw M5 06 07 08 09 10 5 Extension arm length 300mm 11 12 2 Roller 50mm with brake 13 14 2 Roller 50mm electrically conductive 15 1 Slip button Extension tube 16 1 Adjusting lever Swivel arm 10 1 Stand foot 14 13 12 11 10 09 08 07 06 01 02 03 04 05 ...

Page 11: ...Stand foot Dr Mach Lamps and Engineering Edition 01 03 02 2000 Bak Page 11 11 10 2 Stand tube and swivel arm 1 16 5 ...

Reviews: