3. How this Thermometer measures Temperature   

Dr. Trust Infrared Forehead Thermometer measures infrared energy radiated 

from the forehead as well as objects. This energy is collected through the lens and 

converted to a temperature value. Temperature readings are obtained efficiently by 

scanning on the forehead area.   

4. Control Displays and Symbols   

 

All segments displayed  ⑧: Press the ON/OFF button  ⑤  to turn on the unit; all 

segments will be shown for 2 seconds.   

 

Memory  ⑨: The last reading will automatically be shown on the display for 

2 seconds.   

 

Ready for measurement  ⑩: When the unit is ready for measurement, the «°C» 

or «°F» icon will keep flashing while the mode icon (body or object) will be 

displayed.   

 

Measurement complete  ⑪: The reading will be shown on display 4 with the «°

C» or «°F» icon and the mode icon steady. The unit is ready for the next 

measurement as soon as the «°C» or «°F» icon is flashes again. 

 

Low battery indication  ⑭: When the unit is turned on, the battery icon will keep 

flashing to remind the user to replace the battery.   

5. Changing between Body and Object Mode   

For changing from body to object mode, slide the mode switch  ⑥  at the side of 

the thermometer downwards. For switching back to body mode, slide the switch up 

again.   

6. Directions for Use   

Measuring in Body Mode 

1.

 

Press the ON/OFF button⑤. The display  ④  is activated to show all segments 

for 2 seconds. 

2.

 

The last measurement readings will automatically be shown on the display for 2 

seconds with the «M» icon  ⑨.   

3.

 

When  the  « ° C»  or  « ° F»  icon  flashes,  a  beep  sound  is  heard  and  the 

thermometer is ready for measurement⑩.   

4.

 

Place the thermometer at the center of the forehead with a distance of no more 

than 5 cm. If the forehead is covered with hair, sweat or dirt, please remove the 

obstacle beforehand to get accurate reading.   

5.

 

Press the START button 

  and steadily move the thermometer from the 

middle of the forehead to the temple area (about 1 cm above the eyebrow). The 

activated blue tracking light will indicate the measurement area. After 3 seconds 

a long beep will verify the completion of measurement. If unable to reach temple 

area, before the long beep is heard, repeat the measurement as described 

above, but move the thermometer a little faster.   

Summary of Contents for FR200

Page 1: ...1 Infrared Forehead Thermometer User Manual ...

Page 2: ...ter is a high quality product incorporating the latest technology and tested in accordance with international standards With its unique technology this thermometer can provide a stable heat interference free reading with each measurement The instrument performs a self test every time it is switched on to always guarantee the specified accuracy of measurements This Thermometer is intended for the p...

Page 3: ...s Thermometer measures Temperature 4 Control Displays and Symbols 5 Changing between Body and Object Mode 6 Directions for Use 7 Changing between Celsius and Fahrenheit 8 How to recall 30 readings in Memory Mode 9 Error Messages 10 Cleaning and Disinfecting 11 Battery Replacement 12 Technical Specifications ...

Page 4: ... advanced infrared sensor ensures that each measurement is accurate and reliable Gentle and Easy to Use Ergonomic design enables simple and easy use of the thermometer It can even be used on a sleeping child thereby causing no disruption It is quick and child friendly Auto Display Memory The last reading is automatically displayed for 2 seconds when the unit is switched ON Multiple Reading Recall ...

Page 5: ...re be unusually low If the measurement result is not consistent with the patient s finding or unusually low repeat the measurement every 15 minutes or double check the result by another core body temperature measurement This instrument comprises sensitive components and must be treated with caution Observe the storage and operating conditions described in the Technical Specifications section Ensur...

Page 6: ... to replace the battery 5 Changing between Body and Object Mode For changing from body to object mode slide the mode switch at the side of the thermometer downwards For switching back to body mode slide the switch up again 6 Directions for Use Measuring in Body Mode 1 Press the ON OFF button The display is activated to show all segments for 2 seconds 2 The last measurement readings will automatica...

Page 7: ... the temperature in the same location since temperature readings may vary according to locations Doctors recommend rectal measurement for newborn infants within the first 6 months as all other measuring methods might lead to ambiguous results If using a non contact thermometer on those infants we recommend to always verify the readings with a rectal measurement It is recommended to take three temp...

Page 8: ... Reading 30 readings in succession Press and release the START button consecutively to recall the last 30 readings in succession Pressing and releasing the START button 3 after the last 30 readings will resume the above sequence from reading 1 9 Error Messages Measured temperature too high Displays H when measured temperature is higher than 42 2 C 108 0 F in body mode or 100 C 212 F in object mode...

Page 9: ...ns Type Non Contact Thermometer FR200 Measurement Range Body Mode 34 0 42 2 C 93 2 108 0 F Object Mode 0 100 0 C 32 212 0 F Resolution 0 1 C F Measurement Laboratory 0 2 C 36 0 39 0 C Accuracy 0 4 F 96 8 102 2 F Display Liquid Crystal Display 4 digits plus special Acoustic The unit is turned ON and ready for the measurement 1 short beep Complete the measurement 1 long beep 1 sec if the reading is ...

Page 10: ...equirements of the Medical Device Directive 93 42 EEC Technical alterations reserved According to the Medical Product User Act a biennial technical inspection is recommended for professional users Please observe the applicable disposal regulations Remark Some electrical and electrical equipments forbid to abandon and disposal at will Inapplicable baby Attention consult accompanying documents TUV N...