Instruction Manual Dräger GS2

 

 

 

 

 

This gas leak detector uses a semiconductor sensor with a high sensitivity to methane and 
other combustible gases. Basically, such sensors require a certain warm-up time after 
switching on until they show a stable zero signal. The warm-up time is needed to process 
substances that have diffused into the sensor during storage of the device. The Dräger 
GS2 is designed to be ready for operation in the shortest possible time. The default warm-
up time is 30 seconds. Depending on storage and environmental conditions, the default 
warm-up time may not be sufficient. In such a case the Dräger GS2 extends the warm-up 
time to up to 300 seconds. If this extended warmup time is still not sufficient, the Dräger 
GS2 comes up with an error signal and the sensor is defective. 

 

Leakage Detection 

 

Position the instrument such that the gas sensor is purged by ambient air. By rapproche-
ment to a leak and increasing gas concentration the flashing and ticking rate will increase. 
By removing from a leak and decreasing gas concentration the signals will become slower. 
If the signals become fast, slower them by a short press on the push-button. The signals 
will slow down to 1 time every 2 seconds. With increasing gas concentration the signal rate 
will rise. With decreasing gas concentration the zero point will be set automatic. 

 

At a gas leak can be built gas streamers in the ambient air which will be high influ-
enced by air circulation. 

 

Switch off 

 

Switch off the Dräger GS2 by pressing the push-button for a longer time (> 3s). The Drä-
ger GS2 switches off automatically 10 minutes after the last keypress or the last detected 
signal. 

 

Changing the batteries 

 

Unscrew  the  battery  case.  Insert  the  new  micro-batteries  (AAA) in  the  battery  case. The 
positive pole should show to the gas sensor. Screw up the battery case. 
In doing this the Dräger GS2 will switch on automatic. 

 

Function test of the leakage detector 

 

Hold a gas lighter close to the gas sensor, let gas escape out of the lighter without a flame 
burning. The signal rate should increase. 

 

Trouble-shooting 

 

Problem 

Cause 

  Remedy 

 
LEDs light after warm up for 

 

sensor defect    send to service 

10 seconds, after that the 
instrument switches off 

 

LEDs light for 2 seconds and 

 

calibration fault   instrument runs with basic 

than are off for 2 seconds 

 

 

  value (reduced sensitivity) 

before warm up 

 

 

  send to service 

 

Instrument cannot be switched on 

batteries empty   change batteries 