Performance Approvals
Temperature
-40/+65°C (-40/149°F)
Storage temperature
0/+40°C (32/104°F)
Enclosure protection
2)
IP 65/66/67
Range
0-100ppm
Accuracy (whichever is
greater)
measurement uncertainly (of meas. value)
≤
±3 %
or minimum
≤
±0.5ppm
Accessories
Dust filter
6812223
Adapter kit
6810536
Standard
ANSI/ISA-92.00.01FM6340
1) HART communication shall not be used for safety-relevant communication
2) After submersion and jet water the sensor shall be replaced
DrägerSensor H
2
S LC (6809610)
Examination Type P8100
ETR 0400, 0401, 0500, 0501
Interface
1)
4-20mA, relay
Environmental parameters
Humidity
5 to 95%RH, non-condensing
Temperature
-20/+65°C (-4/149°F)
Storage temperature
0/+40°C (32/104°F)
Enclosure protection
2)
IP 65/66/67
Range
0-100ppm
Accuracy (whichever is
greater)
measurement uncertainly (of meas.value)
≤
±3 %
or minimum
≤
±0.5ppm in the range >50ppm, ±10
% or ±3ppm
Accessories
Dust filter
6812223
Adapter kit
6810536
Standard
ANSI/ISA-92.00.01FM6340
1) HART communication shall not be used for safety-relevant communication
2) After submersion and jet water the sensor shall be replaced
DrägerSensor H
2
S (6810435)