中龙集团
Dragon Group China Limited
BIRD
®
section and goes to next flat section.
L1: the aim of the flat section. Range: the entire measuring range of input signals,
limited by SPH and SPL. The procedure will skip this section. One curve has several
slops and flat sections. So we should set every parameter correctly according to specific
requirements.
b
. Adjustment (the parameter code is Ctrl)
When the meter shows PV/SV, press PAR and
↓
for 3s, the meter can enter the menu of
curve program menu, the upper screen display the code of the first parameter, and the
bottom one display the value of parameter. Then we can change the value by
↑
and
↓
.
After the modification, press PAR again and the next parameter and its value display. At
the mean time, the modified data has been saved in the memory.
If no operation within 16s after display of the last parameter, the meter will return to
PV/SV.
c
. The working state of curve procedure working
(
1
)
idIE
When the meter stops, it is used as a thermostatic controller. We can set is at SP,
which will display in the lower screen. When the meter finishes the curve control
procedure, it will go into the stop state (idIE).
(
2
)
RUN
When the meter runs, it modifies SV according to the set curve to let PV change as the
curve program goes on thus control the heating process.
(
3
)
HOLD
When the meter pauses, the timer also stops. SV remains the same, then the time of curve
program is prolonged.
d
. Display when during curve procedure
(1)display of RAMP
When the meter displays ldIE, the RAMP is off.
When the meter displays RUN, the RAMP is on.
When the meter displays HOLD or Hb, the RAMP blinks.
Note: When the CTrl is set at rSP, and the curve goes through the slope, the RAMP
is on.
(2)display while running
When the meter displays RUN, Hb or HOLD, press PAR. The lower screen display
the code r1,d1,r2,d2,
……
Hb and the code of display code.
(3)Display of remaining time
When the meter is on flat section d1or d2, the value displayed under the parameter code is
the remaining time, not the total running time.
(4)display of setting
When the meter is in the state of run
,
Hold or Hb, the lower screen shows the
Summary of Contents for Bird AC-5K
Page 18: ...Dragon Group China Limited BIRD www dragongroupchina com www chinaemall biz...
Page 19: ...Dragon Group China Limited BIRD www dragongroupchina com www chinaemall biz...
Page 26: ...Dragon Group China Limited BIRD www dragongroupchina com www chinaemall biz...
Page 31: ...Dragon Group China Limited BIRD www dragongroupchina com www chinaemall biz...