Required Action
Steps
Manually change the
modulation scheme for
operational checking or
troubleshooting.
Use this command to switch the modulation scheme up or down
manually one modulation step at a time. The command
set haam
manual mode on
must be invoked before this will work. Use the
command
set haam manual mode off
once diagnostics have been
completed.
Sequence:
diagnose haam [up/down]
and press Enter
Example :
diagnose haam down
press Enter
The system responds:
Diagnostic status :Success;
Previous: hy50_364_256qam;
Current: hy50_296_128qam.
HAAM interrupt status register: 0x1100044
Save changes to mib
Saves the MIB to RAM. Perform this command to save setting
changes to non-volatile memory.
Sequence:
save mib
press Enter
The system responds:
MIB saved successfully.
Reset the system to make
changes effective.
Resets (restarts) the system to save the settings to FLASH and
restarts the system with the new settings taking effect.
Sequence:
reset system
press Enter
The system responds:
Are you sure you want to reset? Y(yes) or N(no)
press
Y