Required Action
Steps
Save changes to mib
Saves the MIB to RAM. Perform this command to save setting changes to
non-volatile memory.
Sequence:
save mib
press Enter
The system responds:
MIB saved successfully.
11.3 Coordinated Power Alarm
The coordinated power alarm will get triggered when ATPC is on and the system is transmitting at full
power (i.e. no atpc attenuation) for the last 5 minutes.
Example:
On a link with the atpc threshold at -50 dBm, and the system RSL at -44 dBm, ATPC will add 6 dBm of
attenuation to bring the link RSL down to
–50 dBm. While the link is in this state, a heavy rain storm
occurs for 10 minutes, causing ATPC to remove all of the attenuation to keep the link at -50. Now the
attenuation is 0 and after 5 minutes in this state the coordinated power alarm will be activated. When
the alarm is activated, the system transmit power will be changed to (set txpower - coordinated power
offset) dBm.
To clear a coordinated power alarm execute
set atpc on
again, or
set atpc off
.