WHERE WILL YOU INSTALL THE UNIT?
We recommend installing the system on the
lowest level of the building
to avoid having to work against
gravity. The basement is generally the most ideal location,
near the building’s main drainpipe.
A cold water
pipe must also be available and connected to the unit. Vents are necessary if the unit is further than 6’ (2m)
away from the main drain. If there is no basement, the garage or a storage room will do.
SEPTIC TANK
If your home includes a septic tank, important details are to be considered:
• The unit must be higher than the drain, but the motor can be relocated to reduce the noise
• If the unit is connected directly to the septic tank, the decanter option is mandatory.
INSTALLING THE UNIT
-
FIRST THINGS FIRST -
G
R
OUND
F
LO
O
R
B
A
SE
M
EN
T
SUMP PUMP
* For
compact
models, the bottom of the P-Trap can be installed at 15” (38cm) from the floor.
However,
we recommend 26” (66 cm),
if possible, so that a pail can be placed under the unit, if need be,
when removing the P-Trap.
INSTALLING THE UNIT
-
STEP SEQUENCE -
MINIMUM DIMENSIONS AND SPACING
It is important to install the unit in a location where it will be easily accessible for maintenance and to
effectively evacuate the waste. The following is the
minimum spacing
recommended: