30
most comfortable method of measuring the volume is using the B+B mode and taking
relevant measures on a frozen image.
Measurements – Age tables (foetus age)
After selecting this option and checking the animal type and species from the available list,
the additionally calculated foetus age will be displayed on the information bar, expressed in
days. For some age calculations two foetus measurements will be required.
To disable the age view the user should select and confirm "Disable" option from the list.
Measurements – Clear
Selecting this option will clear the screen from any measurements taken so far. This
operation is carried out to finish the dimensioning process. Additionally, measurement
results may be quickly cleared by pressing the "ESC" button. Also, measurements will be
cleared upon unfreezing the image.
Measurements – Enable/disable grid
After choosing this option and confirming it with OK button a grid will be placed on the image
sector to allow for approximate dimensioning of objects. The grid's resolution is 1.0 cm and
adjusts its scale automatically when scanning depth is changed or when enlargement is
applied (zoom).
Viewfinder. Option of approximate dimensioning with help placed on the image scale
with the resolution of 1mm.
Example of an image with a displayed grid and viewfinder
Measurements – backfat
This option enables automatic measurement of fat thickness. After choosing this option and
confirming it with OK button, freeze the image and hold down for few seconds menu button
.
The line will appear on the screen. If necessary it can be moved to the appropriate level
by using the navigation buttons
. The result given in millimeters is automatically
displayed on the left side of the screen (on the info bar).