INTRODUCTION 

 

The  DRAMINSKI  Ultrasonic  Pregnancy  Detector  for  Dogs  determines 
pregnancy in dogs by locating amniotic fluid in the uterus. 
 
The  ultrasonic  probe  (sensor)  held  against  the  skin  of  the  bitch,  emits 
ultrasonic  sound  waves  which  are  reflected  by  the  amniotic  fluid  in  the 
uterus  of  the  pregnant  bitch  and  return  to  the  probe.  The  reflected 
sound is then measured and analysed by the instrument. 
 
When an airless contact is made between the head of the probe and the 
skin,  the  instrument  signals  this  with  the  diode  (light)  pulsing  and  a 
high-frequency acoustic (sound) signalling regularly once a second. 
 
When pregnancy is detected however, the instrument signals this with a 
rapid  pulsing  of  the  diode  (light)  and  a  corresponding  rapid  high-
frequency acoustic (sound) signal. 
 
The DRAMINSKI Ultrasonic Pregnancy Detector for Dogs is ideally suited 
to  pregnancy  determination  for  individual  breeders,  large  breeding  & 
show kennels, veterinary surgeries and commercial organisations alike. 
 
It is designed to be easy to use, maintain and provide rapid results with 
maximum accuracy. 
 
Testing  can  be  performed  from  3  weeks  after  mating.  However  the 
optimal time for accurate diagnosis is between days 25 & 28, because of 
the  enlargement  of  the  uterus  at  this  time  and  its  movement  slightly 
downward, closer to the peritoneum. Testing prior to day 25 is possible, 

 

but accuracy decreases due to insufficient amniotic fluid being present to 
reflect  the  ultrasonic  waves.  Testing  after  the  optimal  period  is  also 
possible. 

 

DESCRIPTION 

 

The  DRAMINSKI  Ultrasonic  Pregnancy  Detector  for  Dogs  consists  of  the 
following: 
 
1. 

The instrument body with red and green signalling diodes, on/off 
button,  battery  compartment,  probe  connector-cable  output 
terminal and a variable gain control to ‘set’ for the size & weight 
of the bitch to be tested. 

 
2.

 

Ultrasonic sensor probe with co-axial connecting    cable. 

 
3.

 

Alkaline  9  volt  battery  inside  the  battery  compartment  of  the 
instrument body. 

 
4.

 

Plastic carrying and storage case. 

 

 

TEST SETTINGS 

 

Setting  the  potentiometer  (gain  control)  correctly,  is  a  very  important 
factor, which influences the validity of the results obtained by testing. 
 
Bitches vary in regards of weight and size for different breeds and thus 
the gain must be set to the particular position relevant to the size of the 
bitch that is being tested. 
 

For ease the potentiometer has been calibrated to show: 

 
S   

For small bitches 

For medium size bitches 

For larger bitches 

For the giant bitches. 

 
With usage, familiarity and experience, the gain control can be adjusted 
to suit the particular bitch, both in terms of breed type and actual size, 
so that an optimum setting is achieved to ascertain accurate results. 
 
 

Summary of Contents for Pregnancy Detector for Dogs

Page 1: ...DRAMIŃSKI S A Owocowa 17 10 860 Olsztyn Poland Tel 48 89 527 11 30 fax 48 89 527 84 44 e mail info draminski com 1 DRAMIŃSKI Pregnancy Detector for Dogs OPERATION MANUAL www draminski com ...

Page 2: ...e diagnosis is between days 25 28 because of the enlargement of the uterus at this time and its movement slightly downward closer to the peritoneum Testing prior to day 25 is possible 3 but accuracy decreases due to insufficient amniotic fluid being present to reflect the ultrasonic waves Testing after the optimal period is also possible DESCRIPTION The DRAMINSKI Ultrasonic Pregnancy Detector for ...

Page 3: ...nd begin to test Hold the probe against the skin of the bitch at the position shown on the diagram Move the probe in a sliding motion until you achieve a good airless contact indicated by a steady flashing green pulse of light from 5 the diode and acoustic signal beeping at the same frequency Approximately once per second As shown on the diagram when placing the probe against the skin you must dir...

Page 4: ...sted on either side of the bitch in the position indicated and shown on the diagram The probe should be held firmly against the bitch s body but not pressed so as to cause pressure to the abdominal cavity with the ultrasound waves directed at a 40 to 45 degree angle aiming at the spine as shown in diagram Directing the ultrasound waves almost vertically may cause the reflection of urine in a full ...

Page 5: ...red when this appears It is recommended that a high performance alkaline battery is used for this instrument or alternatively a good quality rechargeable battery To change the battery 1 Unscrew both screws which fix the battery cover plate on the rear of the unit 2 Remove battery from its compartment and release from terminals 3 Renew battery fix clasps to correct terminals and replace in battery ...

Reviews: