CARE & CLEANING 

 

Do  not  wet  the  detector,  immerse  it  in  water  or  expose  to  excessive 
moisture,  as  the  instrument  body  is  not  designed  to  be  totally 
waterproof. 
 
Clean  the  instrument  body,  probe  and  cable  with  a  damp  cloth  or 
preferably a ‘wet-wipe’ and dry thoroughly before use or storage.  
 
Store the detector in its carrying case in a clean and dry place when not 
in use. 

 

 

BATTERY REPLACEMENT 

 

Low  battery  power  is  indicated  by  the  red  diode  (light)  and  a  new 
battery  is  required  when  this  appears.  It  is  recommended  that  a  high 
performance alkaline battery is used for this instrument or alternatively 
a good quality rechargeable battery. 
 

To change the battery: 

 
1. 

Unscrew  both  screws,  which  fix  the  battery  cover  plate  on  the 
rear of the unit. 

2. 

Remove  battery  from  its  compartment  and  release  from 

terminals. 
3. 

Renew  battery,  fix  clasps  to  correct  terminals  and  replace  in 
battery compartment. 

4. 

Replace battery cover plate, and replace two fixing screws. 

 
 

TECHNICAL DATA 

 

Dimensions:   

(L)120mm x (W)75mm x (H)30mm 

Net Weight:   

250g approximately 

Power Source: 

Alkaline  9  volt  battery  (automatic  battery  failure 
signal) 

Working Temperature: 

From 0 

o

C to + 60 

o

Summary of Contents for Pregnancy Detector for Dogs

Page 1: ...DRAMIŃSKI S A Owocowa 17 10 860 Olsztyn Poland Tel 48 89 527 11 30 fax 48 89 527 84 44 e mail info draminski com 1 DRAMIŃSKI Pregnancy Detector for Dogs OPERATION MANUAL www draminski com ...

Page 2: ...e diagnosis is between days 25 28 because of the enlargement of the uterus at this time and its movement slightly downward closer to the peritoneum Testing prior to day 25 is possible 3 but accuracy decreases due to insufficient amniotic fluid being present to reflect the ultrasonic waves Testing after the optimal period is also possible DESCRIPTION The DRAMINSKI Ultrasonic Pregnancy Detector for ...

Page 3: ...nd begin to test Hold the probe against the skin of the bitch at the position shown on the diagram Move the probe in a sliding motion until you achieve a good airless contact indicated by a steady flashing green pulse of light from 5 the diode and acoustic signal beeping at the same frequency Approximately once per second As shown on the diagram when placing the probe against the skin you must dir...

Page 4: ...sted on either side of the bitch in the position indicated and shown on the diagram The probe should be held firmly against the bitch s body but not pressed so as to cause pressure to the abdominal cavity with the ultrasound waves directed at a 40 to 45 degree angle aiming at the spine as shown in diagram Directing the ultrasound waves almost vertically may cause the reflection of urine in a full ...

Page 5: ...red when this appears It is recommended that a high performance alkaline battery is used for this instrument or alternatively a good quality rechargeable battery To change the battery 1 Unscrew both screws which fix the battery cover plate on the rear of the unit 2 Remove battery from its compartment and release from terminals 3 Renew battery fix clasps to correct terminals and replace in battery ...

Reviews: