5
4. INTRODUCTION
4.1 SCOPE
This range of portable, direct fired gas heaters are design for industrial applications to give
safe, efficient and reliable operation.
4.2 SPECIFICATION
Stock no. ....................................................... 17681 ..........................................................17682
Part no. ........................................................ PSH50 .....................................................PSH50SS
Rated voltage ....................................... 220-240V~50Hz................................. 220-240V~50Hz
Rated input.................................................... 45W ............................................................. 45W
Heat output ....................................... 14.6kW/50,000BTU ......................... 14.6kW/50,000BTU
Air flow ....................................................... 230m
3
/h .................................................... 230m
3
/h
Gas consumption........................................ 1.05kg/h................................................... 1.05kg/h
Weight (approx.) ...........................................4.7kg .......................................................... 4.7kg
Fuel type ....................................................... I
3P
/I
3B/P
.......................................................... I
3P
/I
3B/P
Regulator pressure .....................................700mbar...................................................700mbar
Min. gas cylinder size .................................... 15kg............................................................ 15kg
Stock no. ....................................................... 17684 ..........................................................17685
Part no. ....................................................... PSH85SS .................................................PSH125SS
Rated voltage ....................................... 220-240V~50Hz................................. 220-240V~50Hz
Rated input................................................... 100W .......................................................... 100W
Heat output .................................16.1-24.9kW/55-85,000BTU.......22-36.6kW/75-125,000BTU
Air flow ....................................................... 535m
3
/h .................................................... 580m
3
/h
Gas consumption....................................1.16-1.79kg/h....................................... 1.57-2.63kg/h
Weight (approx.) ...........................................6.4kg .......................................................... 6.4kg
Fuel type ....................................................... I
3P
/I
3B/P
.......................................................... I
3P
/I
3B/P
Regulator pressure .....................................300mbar...................................................700mbar
Min. gas cylinder size .................................... 15kg............................................................ 25kg
4.3 HANDLING & STORAGE
Although this machine is small in size, care must still be taken when handling and lifting.
Dropping this machine will have an effect on the accuracy and may also result in personal
injury. This machine is not a toy and must be respected.
The environment will have a negative result on its operation if you are not careful. If the air
is damp, components will rust. If the machine is unprotected from dust and debris;
components will become clogged: And if not cleaned and maintained correctly or regularly
the machine will not perform at its best.