FEATURES

Designed to meet International Safety Standards, IEC 1010-1 and VDE0411.

Tear-drop shaped jaws for ease to use in crowded cable areas.

Electronic overload protection up to 250V/A.C. and D.C. on resistance range.

Continuity buzzer ideal for checking the continuity of transformers and motor
coils.

Data Hold Function in all ranges to allow easy reading in hard-to-reach location.

Peak Hold Function allows user to check the status of a transitional period.

Surge and overload protection in ranges.

1.5% accuracy on 0 to A.C. 600A range at 50Hz and 60Hz.

40Hz-1KHz frequency response for A.C. current and voltage measurement.

SPECIFICATIONS

RANGE

FULL-SCALE

RESOLUTION

FREQUENCY

ACCURACY

AC 200A

0-199.9A

0.1A

50/60Hz

±1.5%rdg±4dgt

40-400Hz

±2.5%rdg±4dgt

AC 600A

0-600A

1A

50/60Hz

±1.5%rdg±4dgt

40-400Hz

±2.5%rdg±4dgt

AC 600V

0-600V

1V

50/60Hz

±1.5%rdg±4dgt

40-400Hz

±2.5%rdg±4dgt

DC 600V

0-600V

1V

±1.0%rdg±1dgt

R 2000

0-1999

1

±1.0%rdg±2dgt

Summary of Contents for A.C.

Page 1: ...DIGITAL A C D C CLAMP MULTIMETER STOCK No 56734 PART No DMM9 5 99 INSTRUCTIONS IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS TOOL ...

Page 2: ...to reach location Peak Hold Function allows user to check the status of a transitional period Surge and overload protection in ranges 1 5 accuracy on 0 to A C 600A range at 50Hz and 60Hz 40Hz 1KHz frequency response for A C current and voltage measurement SPECIFICATIONS RANGE FULL SCALE RESOLUTION FREQUENCY ACCURACY AC 200A 0 199 9A 0 1A 50 60Hz 1 5 rdg 4dgt 40 400Hz 2 5 rdg 4dgt AC 600A 0 600A 1A...

Page 3: ...s in all ranges Peak Hold Operates in all ranges Op Temp Humidity 0 C 50 C 80 max RH Storage Temp Humidity 20 C 60 C 80 max RH Power Supply 9V Battery x 1EA 6F22 NEDA1604 or equivalent Dimensions 204 L x 80 W x 43 D mm Accessories include Test leads Instruction manual Battery 9V Carrying Case Option line splitter inline inductive pickup multiplier 132 L x 50 W x 16 D mm Transformer jaws Display CO...

Page 4: ... in mind However no design can completely protect you against incorrect use Electrical circuits can be dangerous and or lethal when lack of caution or poor safety practices are used SAFETY NOTES 3 DESCRIPTION OFWARNING SYMBOLS Earth ground TERMINAL Equipment protected throughout by DOUBLE INSULATION or REINFORCED INSULATION Caution risk of electric shock Caution refer to accompanying document WARN...

Page 5: ...range selector switch to the 200A range position A C VOLTAGE MEASUREMENT 1 Set the range selector switch to the A C 600V range position Insert the red test lead into the V Ω terminal of the instrument and black test lead into the COM terminal 2 Connect the probe tips to the circuit under test and take the voltage reading directly D C VOLTAGE MEASUREMENT 1 Set the range selector switch to the D C 6...

Page 6: ...test and take the resistance reading When the resistance measured reading is below 40Ω the buzzer sounds It is continuity check DATA HOLD FUNCTION The reading will be put on hold when the Data Hold Bottom Switch is pressed If the Bottom Switch is pressed once again it will release the hold and allow a further measurement PEAK HOLD FUNCTION If you press the Peak Hold Bottom Switch the peak reading ...

Page 7: ...bility that the product Stock Number 56734 Part Number DMM9 Description Digital Clamp Multimeter To which this declaration relates is in conformity with the following directive s 73 23 EEC 89 336 EEC With reference to EN61010 1 1995 EN61010 2 31 EN61010 3 32 EN50081 1 EN55022 EN50082 1 EN61000 4 2 3 8 ENV50204 JOHN DRAPER Managing Director 05 99 ...

Page 8: ...703 266355 Fax 01703 260784 Published by Draper Tools Ltd No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without prior permission in writing from Draper Tools Ltd ...

Reviews: