If you encounter any difficulties installing or servicing your AeroLift 35, call your 

dealer or Draper, Inc. in Spiceland, Indiana, 765-987-7999 or fax 765-987-7142.

 Caution: 

1

  Read instructions completely before proceeding. Follow instructions carefully.  

  Installation contrary to instructions invalidates warranty.

2

  Do not obstruct operation of AeroLift 35 with fingers or any other  

  object. Serious injury or damage could result.

3

  It is not uncommon to overheat the motor during initial installation when  

  setting limits. The motor is thermally protected and will stop working  

  temporarily. DO NOT physically pull the unit down when this occurs. Once it  

  has cooled to a safe temperature, it will begin operating again.

4

  The AeroLift 35 is designed to accommodate ceiling suspended  

  equipment. Equipment should not be allowed to rest on ceiling closures  

  during operation (see “Installing Projector”).

5

  Entire bottom of unit must be unobstructed to permit proper operation.

6

  Unit must be installed level (use a carpenter’s level).

7

  Unit operates on 220-230V AC current.

Note:

 

Unit has been thoroughly inspected and tested at factory and found to be 

operating properly prior to shipment.

Planning

1

  Based on screen location and projector specifications, determine proper  

  position for projector installation.

2

  Confirm that there is adequate space for installation and operation. Minimum  

  clearance above ceiling level varies according to height of projector, projector  

  mounting bracket, optional ceiling closure and optional Environmental Air  

  Space Housing.

3

  Arrange to provide service access to the unit.

4

  Total maximum capacity for the AeroLift 35 is 15.9 kg.  

  (including closure, projector and bracket).

As Soon As AeroLift Arrives

1

  Open carton and inspect for damage.

2

  Locate the following parts:

  A. The unit itself

  B. Controls  

  C. Any optional equipment

Test lift 

prior to installation

.

AeroLift 35

(with Closure panel)

Hanging Unit

The AeroLift is provided with four (4) mounting angles for suspending or direct mounting the unit from above, or direct mounting from the sides. These angles provide 

up to 32mm of adjustment (side to side). The AeroLift 35 is designed to fit between joists spaced 41cm apart on center (assuming 51mm joists), and to close to 

aproximately 102 mm, not including the projector, bracket or closure. The unit should be guy wired or blocked to prevent swinging.  

All installations should observe the following guidelines:

1

  Installer must ensure that all fasteners and supports are of adequate strength to securely support AeroLift 35 and projector. It is recommended that hardware  

  structure be able to hold at least four times the combined weight of the lift, projector, housing, closure and ceiling material attached to closure.

 Caution: DO NOT hang from, "ride" or pull down on the unit.This could create a failure and cause damage and/or injury.

2

  Fastening methods must be suitable for mounting surface, and securely anchored  

  so vibration or abusive pulling on unit will not weaken installation.

3

  Bottom of unit must be unobstructed after installation.  

  Sufficient clearance must be allowed below projector or optional ceiling closure.

4

  Do not use unit to support adjacent ceiling, light fixtures, etc.

5

 Do not complete the ceiling below the unit until electrical 

connections  

  have been completed and unit has been operated successfully.

6

  Use slots on the projector plate and on the closure to adjust the  

  unit to ensure proper alignment of ceiling closure relative to  

  ceiling opening.

508mm

257mm

492mm

479mm

1

1

/

4

"

19mm

565mm

122mm

318mm

Top View

Side View

318mm

318mm

Front View

AeroLift 35 

(Relevant Mounting Dimensions)

Top 

Mounting

 Hole

Side 

Mounting 

Slots

Top 

Mounting 

Hole

Anti-Slip

Hole

Side 

Mounting 

Slots

Figure 

(1)

Projector can be installed as shown or

 turned 90° depending on projector size.

220V 

Receptacle

Summary of Contents for AeroLift 35

Page 1: ...r damage 2 Locate the following parts A The unit itself B Controls C Any optional equipment 3 Test lift prior to installation AeroLift 35 with Closure panel Hanging Unit The AeroLift is provided with four 4 mounting angles for suspending or direct mounting the unit from above or direct mounting from the sides These angles provide up to 32mm of adjustment side to side The AeroLift 35 is designed to...

Page 2: ... fully down Optional Infrared or Radio Frequency Remote Control If ordered a three button transmitter is provided with up down and stop buttons Unit starts up or down when appropriate button is pressed and may be stopped by pressing off button Factory set limit switches stop unit automatically when projector is in show position Multiple Station Control required for this option Optional RS232 Ether...

Page 3: ...the ceiling to allow future access The optional environmental air space housing must be installed to isolate the lift from the other space used for environmental air Includes trim ring for ceiling opening See installation instructions included with Environmental Air Space Housing Installing Optional Ceiling Closure If your AeroLift is equipped with optional ceiling closure it can be used as is or ...

Page 4: ...required if both are used with one Lift LVC 3 Button Wall Switch DOWN Black COM White UP Red AeroLift Terminal Block UP N N DN COM Wiring Diagrams Single Station Control To 220 240 Vac Line Dashed Wiring By electrician LS2 LS1 LS2 LS1 BK BL BL BRN OR RD 1 2 3 4 5 6 7 8 TB BK RD BK BK BK BL WH GN YL 14 AWG GN YL RD 14 AWG BK 14 AWG WH 14 AWG GN14 AWG BK 14 AWG BK PROJECTOR OUTLET MOTOR BRN BL L1 N ...

Reviews: