Installing Projector Using Universal Projector Mount

(Maximum Capacity 26 lbs)

See Installation Instructions 

included with Universal Pojector Mount.  

7"

(178mm)

2½"

(64mm)

10" (254mm)

12" (305mm)

12" (305mm)

5½"

(140mm)

7"

(178mm)

2½"

(64mm)

10" (254mm)

12" (305mm)

12" (305mm)

5½"

(140mm)

Figure 

(3)

AeroLift Clearance

Installing Optional Environmental Air Space Housing

  The Environmental Air Space Housing is shipped in pieces, and must be 

assembled by the installer. The height of the Environmental Air Space Hous-

ing is set by drilling out the knockouts at the desired locations then using 

screws to connect side panels. It is recommended that an access panel be 

installed in the ceiling to allow future access. The optional environmental air 

space housing must be installed to isolate the lift from the “other space used 

for environmental air.” Includes trim ring for ceiling opening.

See installation instructions included with Environmental Air Space Housing.

Installing Optional Ceiling Closure

  If your  AeroLift is equipped with optional ceiling closure, it can be used as 

is, or in conjunction with a square of existing ceiling tile.  

See installation instructions included with ceiling closure.

Installing Optional Ceiling Trim Kit

  The  AeroLift is available with a ceiling trim kit, which consists of the lower 

section of the Environmental Air Space Housing and the optional closure 

panel. 

See installation instructions included with Ceiling Trim Kit.

Figure 

(4)

3.1mm Min. clearance

Caution: Make

sure there are

no obstructions

to the AeroLift's

operation

Summary of Contents for AeroLift 35

Page 1: ...r damage 2 Locate the following parts A The unit itself B Controls C Any optional equipment 3 Test lift prior to installation AeroLift 35 with Closure panel Hanging Unit The AeroLift is provided with four 4 mounting angles for suspending or direct mounting the unit from above or direct mounting from the sides These angles provide up to 32mm of adjustment side to side The AeroLift 35 is designed to...

Page 2: ... fully down Optional Infrared or Radio Frequency Remote Control If ordered a three button transmitter is provided with up down and stop buttons Unit starts up or down when appropriate button is pressed and may be stopped by pressing off button Factory set limit switches stop unit automatically when projector is in show position Multiple Station Control required for this option Optional RS232 Ether...

Page 3: ...the ceiling to allow future access The optional environmental air space housing must be installed to isolate the lift from the other space used for environmental air Includes trim ring for ceiling opening See installation instructions included with Environmental Air Space Housing Installing Optional Ceiling Closure If your AeroLift is equipped with optional ceiling closure it can be used as is or ...

Page 4: ...required if both are used with one Lift LVC 3 Button Wall Switch DOWN Black COM White UP Red AeroLift Terminal Block UP N N DN COM Wiring Diagrams Single Station Control To 220 240 Vac Line Dashed Wiring By electrician LS2 LS1 LS2 LS1 BK BL BL BRN OR RD 1 2 3 4 5 6 7 8 TB BK RD BK BK BK BL WH GN YL 14 AWG GN YL RD 14 AWG BK 14 AWG WH 14 AWG GN14 AWG BK 14 AWG BK PROJECTOR OUTLET MOTOR BRN BL L1 N ...

Reviews: