– 16 –
Fault indicator on and no output
− Over-heat protection has
possibly been activated.
− Switch off the device and then
restart it after the fault indicator
is off.
− Wait 2-3min without switching
off the unit. The device may
then naturally restore its self
(the device of pure Argon arc
welding does not have
over-heat protection function)
− Inverter circuit could be
defective.
− Unplug the power supply plug
of the main transformer on the
MOS plate to restart the device.
The previous steps have been
taken to remedy the situation,
but the fault indicator is still on
− Switch off the device and
unplug the power supply plug of
the HF arc striking power
supply.
• If the fault indicator is still
on, it will indicate that some
field-effect tubes on the
MOS plate are broken.
− Find and replace them with
ones of the same type.
• If the fault indicator is off, it
will indicate that the voltage
rise transformer in the HF
arc striking circuit on the
power supply plate is
broken.
− Replace.
The previous steps have been
taken to remedy the situation.
The fault indicator is off, but
there is no output.
• The medium plate
transformer could be broken.
Use an electric bridge to
measure the primary
inductance and Q value of
the main transformer which
should be L=0.4-0.7Mh.
• Some the secondary
rectifying tubes of the
transformer could be
punctured.
− Replace.
− Find and replace with the ones
of the same type.