background image

 WARNING   

Improper installation and use of the Dual Roller Fascia Coupled FlexShade

®

 can result in serious injury or death. Primarily, injuries can occur if the unit falls 

due to imprecise installation, mishandling of the unit during installation or installation on an insufficient wall or ceiling structure. Please use extreme care. 
1. 

Please read the following installation guidelines thoroughly and follow them 

carefully. Failure to do so may cause product to fall or otherwise fail, and could 

result in serious injury. 

2. 

Installation and calibration of the unit should only be performed by an 

authorized, qualified, and experienced professional. In particular, electrical work 

and wiring [indicated in diagram by dashed lines] must be completed only by a 

qualified professional electrician who has read this manual completely and is 

familiar with the construction and operation of this equipment and the hazards 

involved. 

3. 

Do not affix the unit to wall or ceilings that have inadequate strength to 

permanently hold the unit during use. It is the owner’s and installer’s 

responsibility to confirm the wall or ceiling to which the unit attaches is 

sufficient to permanently hold the weight and stress loads of the unit at all times. 

Draper, Inc., is not responsible for improper installation, application, testing, or 

workmanship related to the product at place of installation. 

4. 

It is the installer’s responsibility to ensure appropriate fasteners are used for 

mounting. 

5. 

All brackets, fascia, headboxes, pockets, wall clips, and other hardware must be 

installed level. Unit must be level and square. 

6. 

Never leave the area while operating the unit during installation, maintenance, or 

normal operation, unless it is secure and safe. 

7. 

Before testing or operation, carefully inspect the entire area and path of the 

shade and areas underneath the shade to be sure no persons or objects are in 

the area. 

8. 

Turn off power and any nearby equipment or cables carrying electricity before 

connecting switches, wires, controls, or electrical components. 

9. 

Ensure the limit switches are pointed down or accessible when placing the 

motor in brackets/endcaps.

10. 

All motors should be tested and limits set using test cord before shades are 

wired. 

11. 

Do not wire motors in parallel without written permission from Draper, Inc. 

12. 

During testing or operation, carefully watch the surrounding area for any 

potential safety concerns including nearby persons or objects. 

13. 

After installation, the entire system, including all sensors, should be carefully 

tested to ensure safe and normal operation. Extreme care should be taken 

during testing to remain clear of moving parts to avoid possible injury. 

14. 

Operation of unit should be performed only by authorized and qualified 

personnel, who have been trained in the safe and effective operation of the unit 

and understand its safety features. 

15. 

The safety features of the unit , including sensors, should never be disabled, 

bypassed, or overridden. The system should not be operated until all safety 

features, including the sensors, are properly and completely installed, 

calibrated, and tested. 

16. 

Unit may need to comply with local, state, or district rules and regulations, in 

particular when installed in schools. All applicable rules and regulations should 

be reviewed before installation and use. 

17. 

Failure to precisely follow installation guidelines invalidates all warranties. 

18. 

Custom products/installations may not be reflected in this manual. Call Draper, 

Inc., if you have questions about the installation of custom products or any 

questions about your installation. 

Before Beginning Installation

1. 

Look for any job site conditions that could interfere with installation or operation 

of the system.

2. 

Read carefully and be sure to understand all installation instructions and all 

related operations manuals. These instructions are intended to serve as a guide 

for the installer and owner. They should be followed closely and combined with 

the expertise of experienced qualified installers. Draper, Inc., is not responsible 

for improper installation, application, testing, or workmanship related to the 

product at place of installation. Please retain all instructions for future use.

3. 

Open cartons lengthwise.

4. 

Locate and lay out all pieces.

5. 

Inspect all boxes to ensure you have received the proper shade and parts. 

Controls may be shipped separately, or in same carton as shade.

6. 

If you have any difficulties with installing, servicing, or operating your shade, call 

your dealer or Draper, Inc., 765-987-7999.

Important Safety Information

Important Safety Information

PLEASE READ -

 Important Installation Information

 Caution:

 

1. 

Inspect all boxes to ensure you have received the proper shades and  parts. 

Controls may be shipped separately, or in same carton as shades. 

2. 

Open cartons lengthwise.

3. 

Before mounting shades, verify measurements on label provided with shade, 

and ensure unit is installed at correct width.

4. 

Before connecting switches, controls, or electrical, ensure that power is  

turned 

OFF

. Wiring indicated in diagram by dashed lines must be completed  

by an electrician.

5. 

Do not wire motors in parallel without written permission from Draper.

6. 

All endcaps, fascia, pocket headbox, and other hardware must be installed 

level. Shades must be level and square.

7.  Read the following installation guidelines thoroughly and follow them 

carefully. Failure to do so may cause product to fall or otherwise fail,  

and invalidates warranty.

8.  Installer is responsible for selecting mounting hardware appropriate for  

site conditions.

PLEASE READ -

 Safety Information

PLEASE READ -

 Field Adjustments

Each Draper Solar Control Shade is tested to ensure 

proper operation. Even with this testing, some field 

adjustments may be needed for telescoping. 
If the shade is telescoping, place a piece of high 

quality gaffer tape about 1" 

(25mm)

 wide on the 

exposed roller 

(where the fabric will cover it)

 on the side 

that the fabric will be drawn toward. For example: if 

the fabric is tracking to the left, place the tape on the 

right side.

PLEASE READ -

 Cleaning and Maintenance

Window covering products manufactured by Draper, when properly installed, should require no 
operational maintenance or lubrication.

Most standard Draper fabrics may be cleaned at the window by vacuuming with a soft brush 
attachment. They also may be cleaned by using a sponge or soft cloth and mild solution of warm soapy 
water. A mild dishwashing liquid is recommended. A clean dry cloth is recommended for the metal finish. 

Please Note:

 Exceptions are GreenScreen Evolve, GreenScreen Revive, Flocké and Phifer SW7000 

fabrics, which must be cleaned with a dry art sponge.

page 2 of 10

Dual Roller Coupled Motorized FlexShades

®

 

(Standard Hardware)

Summary of Contents for FlexShade F MO Series

Page 1: ...s 7 8 Section 7 Dimensions 9 10 TOOLS REQUIRED POWER DRILL PENCIL TAPE MEASURE HARDWARE by others LEVEL PLIERS FLEXSHADE F MO Locking Ring SHADE FABRIC SHADE FABRIC Motor Plate Idler End Bracket Spanner Wrench Motor End Bracket Coupler Bracket Assembly Draper Inc 411 S Pearl St Spiceland IN 47385 draperinc com 765 987 7999 800 238 7999 2021 All Rights Reserved FORM Coupled_DR_FS_MO_Standard_Hardwa...

Page 2: ...d regulations should be reviewed before installation and use 17 Failure to precisely follow installation guidelines invalidates all warranties 18 Custom products installations may not be reflected in this manual Call Draper Inc if you have questions about the installation of custom products or any questions about your installation Before Beginning Installation 1 Look for any job site conditions th...

Page 3: ...r End Assembly Please Note The retractable shaft needs to be pointing toward the opposite end of the motor and oriented that direction for the whole unit 1 Insert coupler assembly adapter into roller Making sure the notch in the adapter is lined up with the notch in the coupler press until the adapter is fully seated in the roller 2 Insert coupler assembly into adapter Making sure the notch in the...

Page 4: ...side edge is aligned with the marked location Please Note There is no retractable shaft in the idler end assembly on the idler end shade furthest from the operator This idler assembly utilizes a sliding pin and retainer clip Please Note These instruction steps are for installing endcaps brackets one at a time Brackets endcaps may also all be installed at the same time prior to installing roller fa...

Page 5: ... panel heights can be adjusted so that the bottom edges of the fabric panels are aligned On large units this procedure should be done on only one panel at a time to minimize the amount of fabric weight that must be supported during the adjustment procedure See Fabric Roller Assembly Alignment on page 6 for instructions 10 Repeat steps above under Second Fabric Roller Assembly for additional interm...

Page 6: ...ric panel see Figs 11 and 13 4 Allow the fabric roller assembly being adjusted to move back away from the operator end of the unit and check the position of the fabric panels 5 Tighten the locking ring by firmly rotating it approximately turn clockwise reverse of step 1 Fig 12 6 Operate the unit to check for proper fabric position tracking etc Caution Ensure the locking ring on the idler end coupl...

Page 7: ...Bottom View Side View GLASS SIDE ROOM SIDE Front Back Bottom View Side View Screws Front Back Bottom View Side View GLASS SIDE ROOM SIDE Screws Front Back Bottom View Side View GLASS SIDE ROOM SIDE PUSH BUTTON LIMITS Standard right hand motor configuration shown SCREW TYPE LIMITS Standard right hand motor configuration shown Section 6 Electrical Connections Shade operates on 110 120V 60 Hz current...

Page 8: ...E 2 WHITE 1 BLACK 3 RED 4 GREEN 2 WHITE W B R G To Switch 120VAC To Motor 60 1 5 m Standard 12 30 5 cm Standard M12 Connector for 4 Wire Motors Ø 0 61 15 5 mm Dashed Wiring by Electrician Controls System Overview Sonesse RTS 120VAC Motors M12 Connector B W G RTS MOTOR 120V 110 120V Line DecoFlex Wire Free Keypad Telis 1 RF Remote STOP Data Cable Pin Out RJ45 Connector TE 1 DATA ORANGE WHITE 2 DATA...

Page 9: ...onnector Contact Closure Interface box by others 8 x 1 7 8 deep 4 x 48mm 485 VAC tor Data Cable with RJ45 Connector Dashed Wiring by Electrician Network Device Connector Network Device Connector Network Device Connector Network Device Connector Handheld Remote Wireless Gateway Wall Switch AV Gateway Network Device Connector Contact Closure Interface Controls System Overview 120VAC Motors M12 Conne...

Page 10: ... Headbox Dimensions 19mm 7 197mm 7 197mm 5 127mm 6 167mm 1 46mm 3 81mm 3 76mm 22mm 1 27mm 1 32mm 3 79mm Endcap Fascia Dimensions Dual Roller Pocket Headbox Dimensions Dual Roller Surface Headbox Dimensions OVERALL WIDTH HEM BAR SHADE HEIGHT Fabric Width Overall Width Dim A When measuring shade height remember to include Endcaps Fascia 1 43mm 7 178mm 7 178mm 3 76mm 1 17mm 1 17mm 3 76mm SHADE FABRIC...