background image

FlexShade

®

 ZIP XL

page 2 of 11

 Caution: 

1. 

Inspect all boxes to make sure you have 

received the proper shades and parts. 

Controls may be shipped separately, or in 

same carton as shades. 

2. 

Open cartons lengthwise, taking care not 

to cut into cardboard shipping container.

3. 

Before mounting shades, verify 

measurements on label provided with shade, 

and ensure unit is installed at correct width.

4. 

All endcaps, fascia, headbox, and other 

hardware must be installed level. Shades 

must be level and square.

6.  Read the following installation guidelines 

thoroughly and follow them carefully. 

Failure to do so may cause product to fall or 

otherwise fail, and invalidates warranty.

7.  Installer is responsible for selecting mounting 

hardware appropriate for site conditions.

PLEASE READ -

 Cleaning and Maintenance

Window covering products manufactured by Draper, when properly installed, should require no operational maintenance or lubrication.

Most standard Draper fabrics may be cleaned at the window by vacuuming with a soft brush attachment. They also may be cleaned by using a sponge or soft cloth 

and mild solution of warm soapy water. A mild dishwashing liquid is recommended. A clean dry cloth is recommended for the metal finish. 

Please Note:

 Exceptions are GreenScreen Evolve

®

, GreenScreen Revive

®

, and Phifer

®

 SW7000 fabrics, which must be cleaned with a dry art sponge. 

(GreenScreen Revive

®

 and GreenScreen Evolve

®

 are registered trademarks of Mermet

®

 USA. SheerWeave

®

 is a registered trademark of Phifer

®

 Incorporated.)

 WARNING   

Improper installation and use of the FlexShade

®

 ZIP XL can result in serious injury or death. Primarily, injuries can occur if the unit falls  

due to imprecise installation, mishandling of the unit during installation, or installation on an insufficient wall or ceiling structure.  

Please use extreme care. 

1. 

Please read the following installation guidelines thoroughly and follow them 

carefully. Failure to do so may cause product to fall or otherwise fail, and 

could result in serious injury. 

2. 

Installation and calibration of the unit should only be performed by an 

authorized, qualified, and experienced professional. In particular, electrical 

work and wiring [indicated in diagram by dashed lines] must be completed 

only by a qualified professional electrician who has read this manual 

completely and is familiar with the construction and operation of this 

equipment and the hazards involved. 

3. 

Do not affix the unit to wall or ceilings that have inadequate strength to 

permanently hold the unit during use. It is the owner’s and installer’s 

responsibility to confirm the wall or ceiling to which the unit attaches is 

sufficient to permanently hold the weight and stress loads of the unit at all 

times. Draper

®

, Inc., is not responsible for improper installation, application, 

testing, or workmanship related to the product at place of installation. 

4. 

It is the installer’s responsibility to make sure appropriate fasteners are used 

for mounting. 

5. 

All brackets, fascia, headboxes, pockets, wall clips, and other hardware 

must be installed level. Unit must be level and square. 

6. 

Never leave the area while operating the unit during installation, 

maintenance, or normal operation, unless it is secure and safe. 

7. 

Before testing or operation, carefully inspect the entire area and path of the 

shade and areas underneath the shade to be sure no persons or objects are 

in the area. 

8. 

Turn off power and any nearby equipment or cables carrying electricity 

before connecting switches, wires, controls, or electrical components. 

9. 

Make sure the limit switches are pointed down or accessible when placing 

the motor in brackets/endcaps.

10. 

All motors should be tested and limits set using test cord before shades  

are wired. 

11. 

Do not wire motors in parallel without written permission from Draper, Inc. 

12. 

During testing or operation, carefully watch the surrounding area for any 

potential safety concerns including nearby persons or objects. 

13. 

After installation, the entire system, including all sensors, should be carefully 

tested to ensure safe and normal operation. Extreme care should be taken 

during testing to remain clear of moving parts to avoid possible injury. 

14. 

Operation of unit should be performed only by authorized and qualified 

personnel, who have been trained in the safe and effective operation of the 

unit and understand its safety features. 

15. 

The safety features of the unit, including sensors, should never be disabled, 

bypassed, or overridden. The system should not be operated until all safety 

features, including the sensors, are properly and completely installed, 

calibrated, and tested. 

16. 

Unit may need to comply with local, state, or district rules and regulations, 

in particular when installed in schools. All applicable rules and regulations 

should be reviewed before installation and use. 

17. 

Failure to precisely follow installation guidelines invalidates all warranties. 

18. 

Custom products/installations may not be reflected in this manual. Call 

Draper, Inc., if you have questions about the installation of custom products 

or any questions about your installation. 

Before Beginning Installation
1. 

Look for any job site conditions that could interfere with installation or 

operation of the system.

2. 

Read carefully and be sure to understand all installation instructions and 

all related operations manuals. These instructions are intended to serve 

as a guide for the installer and owner. They should be followed closely and 

combined with the expertise of experienced qualified installers. Draper, 

Inc., is not responsible for improper installation, application, testing, or 

workmanship related to the product at place of installation. Please retain all 

instructions for future use.

3. 

Open cartons lengthwise.

4. 

Locate and lay out all pieces.

5. 

Inspect all boxes to make sure you have received the proper shade and 

parts. Controls may be shipped separately, or in same carton as shade.

6. 

If you have any difficulties with installing, servicing, or operating your shade, 

call your dealer or Draper, Inc., 765-987-7999.

Important Safety Information

Important Safety Information

PLEASE READ -

 Important Installation Information

PLEASE READ -

 Safety Information

Summary of Contents for FlexShade ZIP XL

Page 1: ...d IN 47385 draperinc com 765 987 7999 800 238 7999 2021 All Rights Reserved FORM FS_ZIPXL_Inst20 FlexShade ZIP XL XL exterior shading system ZIP detail creates weather shading barrier that protects against wind sun snow and insects to maintain a comfortable space INSTRUCTIONS INSTALLATION OPERATION If you have any difficulties installing or servicing your FlexShade ZIP XL call your dealer or Drape...

Page 2: ...adboxes pockets wall clips and other hardware must be installed level Unit must be level and square 6 Never leave the area while operating the unit during installation maintenance or normal operation unless it is secure and safe 7 Before testing or operation carefully inspect the entire area and path of the shade and areas underneath the shade to be sure no persons or objects are in the area 8 Tur...

Page 3: ... brackets are level and aligned 4 Attach Headbox to brackets and tighten Set Screws Fig 3 A 5 Mount the Side Channels Section 3 1 Attach Mounting Brackets to ceiling using 10 flat head screws installed flush with bracket USE ALL FOUR 4 mounting holes Fig 3 B 2 Attach Headbox to brackets and tighten Set Screws Fig 3 B 3 Mount the Side Channels Section 3 Caution Hem Bar does not retract into the Hea...

Page 4: ...d Pocket Optional FlexShade ZIP XL can also be installed in a pocket in ceiling 4 Mark wall or jamb and drill small pilot holes in mounting surface Please Note Recommended attachment of Side Channel to structure is minimum of every 24 61cm B A C DO NOT remove Neoprene cushions If they come off reattach with double sided tape SIDE CHANNEL COVER Jam b M ount Pilot Hole W all M ount Pilot Hole Wall M...

Page 5: ...ngaged in Headbo 2 Insert Zipper on one side of Hem Bar into Fabric Retainer in Side Channels 4 Attach Side Channel to mounting surface using appropriate fasteners IMPORTANT Side Channels must be installed parallel plumb and square with a tolerance of 1 8 3mm 5 Repeat Steps 2 4 for the other Side Channel 6 Re attach Side Channel Covers using the screws removed in Step 1 Please Note Failure to use ...

Page 6: ...e remaining Side Channel mounting location Please Note Installer is responsible for providing space and clearance to mount headbox above wall structure W A L L W A L L 2 51mm 1 Insert provided U Channel PN C090 061 into recessed cavity in building structure Secure the U Channel using appropriate hardware by others Please Note Installer is responsible for selecting mounting hardware appropriate for...

Page 7: ...tons until motor moves down then release Use UP and DOWN buttons to move shade to correct lower limit and press MY STOP 4 While motor is at lower limit hold UP and MY STOP buttons until motor moves up then release The shade should move to upper limit and stop 5 Next hold MY STOP button for five seconds until motor jogs 6 Put motor into USER MODE by pressing small programming button Fig 4 on the ba...

Page 8: ...ach limit switch must be set prior to connecting to system Motor must be installed so limit switches are pointed up or accessible 7 Operate shade to desired down stop position Set limit by turning proper socket toward to lower limit and to raise it 8 Operate shade to desired up stop position Set limit by turning proper screw toward to raise limit and to lower it Please Note Each full rotation of t...

Page 9: ...HING ONLY 1 REQUIRED Cable Exit Hole Ø 11mm Figure 6 19mm 17mm Cable Exit SIDE TOP BACK 13mm SIDE Endcap F R O N T F R O N T 9 5mm 13mm 22mm 1 25mm Cable Exit TOP TOP BACK 13mm SIDE Endcap F R O N T F R O N T 9 5mm 13mm 1 30mm Cable Exit BACK TOP BACK 13mm SIDE Endcap F R O N T F R O N T F R O N T Figure 7 A Figure 7 B Figure 7 C Section 12 Anti Insect Brush Seals Optional 1 Remove the double side...

Page 10: ...eadbox Height B 5 127mm 1 41mm Celing Mount Option Wall Mount Option Top View Down 8mm 5 127mm 3 92mm 5 127mm 1 41mm SHADE HEIGHT 7 184mm Ceiling Mounted Headbox with Jamb Mounted Side Channels Top View Down 5 127mm 3 92mm 1 41mm SHADE HEIGHT 8mm 7 184mm 5 127mm Wall Mounted Headbox with Deck Mount Option Wall Mount Option FlexShade ZIP XL page 10 of 11 ...

Page 11: ...8mm 6 152mm 1 25mm 1 44mm 2 57mm 1 25mm 1 41mm 9 5mm 1 41mm 19mm 2 51mm 1 25mm 5 127mm 5 127mm 5 127mm Curved Headbox Angled Headbox Optional Channel Adaptors Side Channel Dimensions Hem Bar Dimensions Headbox Dimensions 1 38mm 1 38mm 2 4mm 19mm C073 002 6mm 1 29mm 1 41mm 19mm 1 6mm 9 5mm C090 053 3mm 1 32mm 1 38mm C104 148 1 29mm 1 41mm 1 44mm 1 6mm 9 5mm 6mm C090 054 2 51mm 2 51mm 3 2mm C090 061...