background image

Copyright © 2014 Draper Inc.  Form ScissorLiftSLX_Inst14-R  Printed in U.S.A.

Installation/Operating Instructions

Scissor Lift SLX Video Projector Lift by Draper

Electrical Connections

Unit operates on 115V AC, 60 Hz. current. 

10.93 amps current draw (3.93 amps for lift, 7 amps for outlet). 

Opening the electrical box exposes terminals for field connections. 

Unit is shipped with internal wiring complete.

Wire to connect unit to power supply should be furnished by installer. 

Connections should be made in accordance with wiring diagram,  

and wiring should comply with national and local electrical codes. 

An appropriate disconnect device shall be provided as part of the building 

installation. All operating switches should be “off” before power is connected.

Caution: Make sure electrical supply has been disconnected before 

attempting to connect Scissor Lift to electricity.

Scissor Lift should be operated and checked prior to installing projector and/or 

optional ceiling closure.

Low Voltage Control Switch shown on Page 2

 comes with 22.8 m of non-

plenum rated cable and should be plugged in to Control Panel on top frame of lift 

for control of the "Up" and "Show" positions. 

Momentary Key Switch shown on Page 2 

comes with 22.8 m of cable and 

should be plugged in to Control Panel on top frame of lift for control of the 

"Service" position.

 

 

 

 

If you encounter any difficulties installing or servicing your Scissor Lift SLX, call your 

dealer or Draper, Inc. in Spiceland, Indiana, 765-987-7999, or fax 765-987-7142.

Caution:

ImPOrtAnt SAfety InStrUCtIOnS

Read all instructions completely before proceeding.

WARNING/AVERTISSEMENT

RISK OF ELECTRIC SHOCK. DO NOT OPEN

RISQUE DE CHOC ELECTRIQUE. NE PAS OUVRIR.

 DAnGer: to reduce risk of shock:

1

  Always disconnect power from lift before cleaning.

 WARNING–To reduce risk of burns, fires, electric shock or injuries to persons:

2

 Disconnect power from lift before putting on or taking off parts.

3

 Use this lift only for its intended use as described in these instructions.  

  Do not use attachments not recommended by the manufacturer.

4

  Never operate this lift if it has a damaged cord or plug. If it is not working  

   properly, call your dealer or the manufacturer for assistance/repair.

5

  Keep cords away from heated surfaces.

6

  Never operate lift with air opening blocked. Keep the air openings free of lint,  

   hair, and the like.

7

  Never drop or insert any object into any opening.

8

  Do not use outdoors.

9

  Route cords and cables as shown in the instructions.

10

   

WARNING:

 

Rick of Electric Shock— 

  connect this product to a properly grounded electrical supply.

ImPOrtAnt InStALLAtIOn/OPerAtInG InStrUCtIOnS

 WARNING: To prevent injury, this apparatus must be securely attached to    

  the building structure in accordance with the instructions.

11

  Test lift prior to installation. 

 

Please Note: Packaging must be removed from lift before testing.

12

  Follow instructions carefully. Installation contrary to instructions invalidates warranty.

13

  Do not obstruct operation of Scissor Lift SLX with fingers or any object.  

  Serious injury or damage could result.

14

  Lift is intended for use with product weighing not more than 350 pounds.

15

  Scissor Lift SLX is designed to accommodate ceiling suspended equipment.  

 

equipment should not be allowed to rest on optional ceiling closure  

  during operation (refer to section titled “Installing Projector”).

16

  Entire bottom of unit must be unobstructed to permit proper operation.  

  Sufficient clearance must be allowed below projector or optional ceiling closure:  

  10' for Model SLX10, 14' for Model SLX14, etc.

17

  Unit must be installed level (use a carpenter’s level).

18

  Unit operates on 115V AC 60 Hz. current. 10.93 amps current draw (3.93  

  amps for lift, 7 amps for outlet).

19

 Verify the show position when testing lift. Make required changes by referring  

  to adjustment instructions on page 4 of this document.

20

  The maintenance/service factory limit setting must not be adjusted to a lower  

  position than the preset factory limit setting. In addition, Draper does not  

  recommend setting show position at the maintenance/service position—for  

  example, if you wish to have 8' show position, order a lift with at least a 10'  

  maintenance position.

21

 

When the Scissor Lift SLX is to be installed in “other space used for  

  environmental air” the optional environmental air space housing must  

  be installed per instructions to isolate the lift from the “other space  

  used for environmental air.” 

22

  When Scissor Lift SLX is 

nOt 

installed in environmental air space housing   

  and optional ceiling closure, the 

ALTERNATE

 wiring for up limit switch may  

  be used 

(see Alternate Wiring schematic on page 5).

 CAUTION: Before servicing unit, disconnect hardwired control and any 

remote control.

Note:

 

Unit has been thoroughly inspected and tested at factory and found to be 

operating properly prior to shipment.

Planning

1

  Based on screen location and projector specifications, determine proper  

  position for projector installation.

2

  Confirm that there is adequate space for installation and operation. 

  Minimum clearance above ceiling level varies according to Scissor Lift model,  

  plus height of projector, optional mounting bracket, optional ceiling closure,  

  and optional Environmental Air Space Housing.

3

  Arrange to provide service access to the unit.

4

  Maximum lifting capacity is 350 kg.

As Soon As Scissor Lift Arrives

1

  Open carton and inspect for damage.

2

  Locate the following parts:

  A. the unit itself
  B. Controls 
  C. Optional equipment: 

     

I.   Environmental Air Space Housing,  

     

II.  Universal Projector Mount, 

     

III. Closure Panel or Ceiling Finish Kit 

     

     

(all ship in separate cartons).

3

  Test lift prior to installation.  

 

Please Note: Packaging must be removed from lift before testing.

Caution: 

 

Beware of pinch points

Caution: Beware  

of pinch points

Summary of Contents for SLX

Page 1: ...ior to installation Please Note Packaging must be removed from lift before testing 12 Follow instructions carefully Installation contrary to instructions invalidates warranty 13 Do not obstruct operation of Scissor Lift SLX with fingers or any object Serious injury or damage could result 14 Lift is intended for use with product weighing not more than 350 pounds 15 Scissor Lift SLX is designed to a...

Page 2: ...e cautious If unit fails to operate properly press STOP and recheck electrical connections before proceeding Cycle unit down and up several times to confirm satisfactory operation Caution Do not pull on or touch safety belt when unit is in motion If belt locks the cables will unspool Caution Obstructing bottom pan may cause cables to unspool Caution Do not operate Scissor Lift SL without a minimum...

Page 3: ...on of the surrounding ceiling units should be operated to confirm that optional ceiling closure panel stops just short of touching ceiling in closed position Warning Keep fingers and other objects away from automatic ceiling closure and scissor mechanisms when unit is operating Serious injury or damage could result Attaching Universal Projector Mount to Projector Pan If you ordered the unit with o...

Page 4: ...sed a motor failure may occur Installing Optional Ceiling Trim Kit The Scissor Lift SLX is available with a Ceiling Trim Kit which consists of the lower section of the Environmental Air Space Housing and the optional closure panel see Fig 6 1Install Scissor Lift SLX as previously described in these instructions 2Install bottom section of Environmental Air Space Housing and Trim Ring in opening Thi...

Page 5: ...position is now cleared and ready for a new show position to be set PROCEDURE FOR SETTING SHOW POSITION 1 Now that the show position has been cleared use wall switch up and down buttons to get lift into desired show position 2 While lift is at desired show position press and hold the Key Down toggle switch until lift begins to move upward Lift will begin a calibration cycle where it will move upwa...

Page 6: ...s located in the plastic sleeve with these instructions ROTATE TO ADJUST DOWN Limit Switch R R R R R R R ROTATE T T T T T T TO O T T A A A A A A ADJ A A A A A UST DOWN Adjusting FULLY DOWN position Limit switches for the Scissor Lift SL are preset at the factory The DOWN limit switch is set for the fully down maintenance position for the size lift you have ordered The limit switch assembly is loca...

Page 7: ...921 mm 391 16 992 mm 42 1067 mm 35 889 mm 19 16 39 6875 mm 1 8 3 175 mm Top View Front View Side View 39 1 8 994mm x 39 1 8 994mm Lipless Closure Dimensions Scissor Lift SLX Dimensions Table A Closed Extended Model Height Height SLX10 141 16 10 7 SLX14 165 16 14 2 SLX17 189 16 17 8 SLX21 2013 16 21 3 SLX24 231 16 24 9 SLX28 255 16 28 5 5 20 41 48 22 19 41 Front Back View Side View ...

Page 8: ...28 544 02SA Frame SLX Plenum 2 1 C028 545 07SA Frame SLX Trim Ring 3 4 C044 178SA Panel SLX Plenum Side 4 4 C044 180SA Panel SLX Plenum End 5 2 C044 179SA Panel SLX Middle End 6 2 C044 177SA Panel SLX Plenum Middle Side 7 1 C095 123SA Cover SLX Plenum 8 28 C020 325 Screw 8 32 x 3 8 Type 1 HWH 9 40 C018 051 Nut 8 32 Zinc Hex KEPS 10 12 C013 070 Washer 188 I D x 5 O D x 07 TK Nylon Flat 11 24 C020 1...

Reviews: