Scissor Lift SLX by Draper
page 6 of 8
www.draperinc.com
(765) 987-7999
Wiring Schematic
N
U
C
D
Dashed wiring by electrician
115V ac, Suppl
y
Attached to lower pan
WH
BK
BK
WH
GN
WH
Low voltage wiring by others
Low Voltage Trigger (6-24 VDC)
WH
Encoder
RD
BK
RD
WH
RD
WH
BK
Wall Switch
Key Switch
RP/RQ Bus Ports for
remote controls such
as IR Eye, RF Receiver,
LED Wall Switch and
RS232.
WH
RD
BN
RD
WH
BK
YL
YL/GN
RD
BK
BK
OR
Up Limit
Switch
NC
NC
RD
BN
NC
Down Limit
Switch
Delay Switch
(ON position)
RD
BK
BK
OR
BK
BK
RD
BL
YL/GN
BK
Motor
Up
Down
BK
BK
BK
WH
OR
RD
BK
BK
WH
OR
RD
AC
AC
COM
N.O.
N.C.
BK
WH
RD
OR
Optional Delay Assembly
115V ac, 7A 60 Hz Outlet
Run Cap
60 MFD
2 Cond. Cable
RD
BK
BK
OR
Up
Limit
Switch
NC
NC
BK
Jumper*
ALTERNATE ‘UP’ LIMIT SWITCH WIRING
nOte: this CAnnOt be
used when lift is installed in
environmental Air Space Housing
and Optional Ceiling Closure
*Black (BK) Jumper wire is
located in the plastic sleeve
with these instructions.
ROTATE
TO
ADJUST
DOWN
Limit
Switch
R
R
R
R
R
R
R
ROT
ATE
T
T
T
T
T
T
TO
O
T
T
A
A
A
A
A
A
ADJ
A
A
A
A
A
UST
DOWN
Adjusting fULLy DOWn position
Limit switches for the Scissor Lift SL are preset at the factory.
The
DOWn
limit switch is set for the fully down (maintenance) position
for the size lift you have ordered. The limit switch assembly is located
inside the lift and behind the Lifting Cable Drum.
The Down limit switche shown in the drawing are for setting the "Fully
Down" position. This can be adjusted manually by loosening or tightening
the screw to increase or reduce the travel.
Caution:
The maintenance/service factory limit setting must
not be adjusted to a lower position than the preset factory limit
setting. In addition, Draper does not recommend setting show
position at the maintenance/service position.
Adjusting Limit Switches
PLEASE NOTE:
Changing the fully open or fully closed position will reset the electronic controls and cause the lift to operate improperly.
Please call Draper before attempting these adjustments.
Figure 8