16
11. MAINTENANCE
11.2 GENERAL MAINTENANCE AND SERVICE
INTERVALS – FIGS. 9-11
After the first 10 working hours:
– Clean crankcase and renew lubricating oil.
After every 20 working hours:
– Check the oil level
and replensish if necessary.
After every 50 working hours:
– Ensure all fixings have remained tight, particularly
on the head and crankcase.
After every 60 working hours:
– Open drain cock
under the tank to exhaust
condensate.
After every 120 working hours:
– Clean crankcase and renew the oil, clean air filter
and check safety valve and pressure gauge after.
FIG.9
FIG.10
FIG.11