background image

Client

Drayton

File Name

7542 Drayton LP10RF & D2RF 06515086001 ISSC

Artworker

-

Proof Stage

PRINT

Finished Size

A5 148x210mm

Creative Director

Mike Lane

Artwork %

100%

Modification Date

21/08/15 2:56PM

Bleed

3mm

Installation Guide  

LP10RF & D2RF

CLOCK?

6:30

10:30

OFF

Before fixing the D2RF to the wall it is 

recommended to first check the signal strength from that 

location.

To do this, after initial start up, the colon, CH and antenna 

symbols should be flashing on the LP10RF display.

1. 

Press the set? button 4 times. 

2. 

Press the OK button once. 

3. 

Press the set? button 4 times; Lrn and OFF should 

be displayed. 

4. 

Press the + button so the display shows ON and a 

flashing antenna symbol. The learn mode is now 

ready to receive a signal from the transmitter 

during the next two minutes. 

5. 

Take the D2RF unit and stand near the 

boiler. 

6. 

Remove the battery cover and fit the batteries. 

7. 

The symbols on the receiver will stop flashing and 

the display will show ‘SSI, Antenna and ON’. 

8. 

Press ‘SET’ on the receiver and the display will

show ‘SSI and Antenna’. 

CLOCK?

6:30

10:30

OFF

CLOCK?

6:30

10:30

OFF

9. 

After a few seconds the display will show ‘- - -’. 

Remove the batteries from the D2RF, 

press and hold the ‘+’ button whilst refitting the 

batteries, keep the ‘+’ button held and after a few

seconds the display will show ‘rF’ which indicates 

that the D2RF is continuously sending a 

signal to the LP10RF (receiver). 

The receiver display will now show the ‘learnt’ 

transmitter code and the antenna’ as well as the 

signal strength as indicated by the chevrons on the

right hand side of the display.

J   

Place the transmitter in the desired final position

and return to the boiler to check the receiver 

display. The ideal transmitter position will result 

in the receiver display showing 4 chevrons and the 

LED will be green. 

K   

If the LED is red or no LED is showing and the

display indicates 1 or 2 chevrons, the transmitter 

will need to be re-positioned until the LED 

changes to amber or green and 3 or 4 chevrons are 

indicated on the display.

 

NOTE:

  

If there is no LED and the display shows ‘- - -’, there 

is no signal being received at all from the transmitter. 

Transmission will resume once the transmitter is re-

positioned in a part of the house where an amber or 

green LED and 3 or 4 chevrons are achieved.

L   

Once you are happy that, when in the desired 

location, the transmitter is sending a good signal 

to the receiver i.e. amber or green and 3 or 4 

chevrons, the transmitter can be fixed to the wall.

CLOCK?

6:30

10:30

OFF

LED Indication Chevrons

 RF Strength

Green

4

Very strong

Amber

3

Strong

Red

2

Weak

None

1

Very weak

Signal strength 

indicators

Transmitter code

(may be different)

LED indicator shows different colour depending

on signal strength (see table below)

Wireless Commissioning 

& Signal Strength

5

LP10RF & D2RF

06

51

5086

0

0

1 I

SS

C

Summary of Contents for DIGISTAT+2RF

Page 1: ...ication Date 21 08 15 2 56PM Bleed 3mm LP10RF DIGISTAT 2RF Radiofrequencycontrolledprogrammableroom thermostatwithdomestichotwaterprogrammer PartnumberRF560DR Installation UserGuide ForGREENSTARCDi GREENSTARiJUNIORandGREENSTARSiMODELSalso GREENSTARiSYSTEMandGREENSTARCDiSYSTEMMODEL onlywhenusedwith theoptionalintegraldiverter SparesPartnumber22090 SparesPartnumber22589DR ...

Page 2: ... Celsius Centigrade IP IngressProtection V Volt m metre mA milliAmpere Definitions DLS BST Summertimebegins LastSundayinMarchat 1 00amGMT Clocksareputforwardby1hour Summertimeends LastSundayinOctoberat 2 00amBST Clocksareputbackby1hour Protectyourenvironment Properbatteryrecycling Electronicdevicesandbatteries rechargeableornot shouldnotbedisposedofintoordinaryhouseholdwaste Instead theymustberecy...

Page 3: ...m Tableofcontents TechnicalData 2 InstallationGuide 3 LP10RFInstallation 4 WirelessCommissioning SignalStrength 5 6 SignalStrength 7 InstallerOptions 8 9 UserGuide 10 DIGISTAT 2RFRoomThermostat 11 ControlsandDisplayLayout 12 BasicSettings 13 15 UserOptions 15 19 BatteryChange 19 LP10RFProgrammer Receiver 20 TheStandardProgram 21 ChangingtheProgram 22 25 Maintenance 25 1 LP10RF DIGISTAT 2RF 0651508...

Page 4: ... Batterylife withalkalinebatteries approx 2years N A Batterybackuptimeanddate 10yearsmin 10yearsmin Shortestswitchingperiod 1minute 1minute Hotwaterpre heatsettings 3ON 3OFF Centralheatingsettings 6perday EnergyClass IV 2 Acc EU811 2013 812 2013 813 2013 814 2013 PollutionClass 2 2 SoftwareClass A A Ballpressuretest 90 C 90 C TechnicalData RelevantECDirectives 2006 95 ECLowVoltageDirective 2004 10...

Page 5: ... DIGISTAT 2RF06515086001ISSC Artworker Proof Stage PRINT Finished Size A5 148x210mm Creative Director Mike Lane Artwork 100 Modification Date 21 08 15 2 56PM Bleed 3mm InstallationGuide LP10RF DIGISTAT 2RF 3 LP10RF DIGISTAT 2RF 06515086001 ISSC ...

Page 6: ...singbefore switchingontheelectricalsupplyandboiler J Switchboileronwhencompleted CAUTION Isolatethemainselectricitysupply beforestartinganyworkandobserve allrelevantsafetyprecautions Observeelectro staticdischarge precautions donottouchthepcb circuit DANGER 230voltsdonottouchtheelectrical componentsorcircuits F InstallationGuide LP10RFProgrammer Receiver Clips Cover panel Tab Blanking plate Tab Co...

Page 7: ...secondsthedisplaywillshow rF whichindicates thattheDIGISTAT 2RFiscontinuouslysendinga signaltotheLP10RF receiver Thereceiverdisplaywillnowshowthe learnt transmittercodeandtheantenna aswellasthe signalstrengthasindicatedbythechevronsonthe righthandsideofthedisplay J Placethetransmitterinthedesiredfinalposition andreturntotheboilertocheckthereceiver display Theidealtransmitterpositionwillresult inth...

Page 8: ...suitablewallplugsand screws 3 Replacethefrontcoverbylocatinginpositionand pushingfullyontothebackcover Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2R...

Page 9: ... buttononthetransmitter whilere insertingthebatteriesandkeepthebutton depresseduntilthedisplayshows rF 6 30 OFF 6 30 OFF 6 30 OFF 6 30 OFF LEDIndication Chevrons RFStrength Green 4 Verystrong Amber 3 Strong Red 2 Weak None 1 Veryweak Tocancelsignalstrengthmode 1 Removethebatteriesfromthetransmitterto canceltheconstanttransmission 2 Afterafewsecondsthereceiverdisplaywillshow 3 Press OK onthereceive...

Page 10: ...ait until next change in the pre set program temperature shown flashing 3 Once the temperature has been set press to confirm and move to the next time and temperature periods to be adjusted confirming changes by pressing button max 6 periods 4 To exit press or until you return to auto mode with the bottom arrow pointing to auto as shown Drayto n Digist at 2RF Digist at 2RF Drayto n Drayto n Drayto...

Page 11: ...iodisoperatingindicatedbythe flamesymbolflashing pressinganybuttonreturnsthe Digistattoautomodeallowingnormalbuttonoperation untilthenexttime temperatureevent whenitwill resumethedelaystartmodeorfollowstheHoliday Manual OverrideorOffmodesasselected Changestotheinstalleroptionsandpre setprogrammes mustbemadewiththeflamesymbolnotflashing Option10 ValveProtection Insomeheatingsystemstheremaybearequir...

Page 12: ...UserGuide LP10RF DIGISTAT 2RF 10 Installation UserGuide 06515086001 ISSC ...

Page 13: ... Room Thermostat Wireless 24 Hour Model RF700 22090 Power Supply Battery Thermostat Mains Digistat SCR The Digistat 2RF thermostat is a programmable thermostat 24 Hour product the same program for every day of the week which allows you to set up to 6 time and temperature events per day Clock Setting Your Digistat 2RF is fitted with a real time clock which is pre set at the factory You will not hav...

Page 14: ...left hand button moves the pointer to the left for selection Holiday Manual Auto Day Program Pointer mode indicator Time Flame shows when calling for heat Pointer day Days Temperature NOTE Temperaturedisplayedisactualroomtemperature unlessadjustingthe or buttonwhenitdisplays thesettemperature Onceadjustmentiscomplete andafter5secondsthiswillreturntoactualroom temperature UserGuide DIGISTAT 2RFRoom...

Page 15: ...ame program for every day of the week and allows you to set 6 time and temperature events per day Digistat 2RF Pre set Program Your Digistat 2RF comes with the following default settings pre programmed for your convenience Pre set Program 1 9 til 5 The above settings can be understood using the chart below 25ºC 20ºC small 1 in lower half of screen shows which time period is being set e g 1 1st per...

Page 16: ...gistat 2RF Alkaline batteries play the batteries will cease to tteries Drayton To set a constant room temperature Manual mode 1 Press once the display shows temperature flashing example 20 0 C 2 Press or buttons to adjust the temperature as required The temperature will stop flashing after 5 seconds and start controlling at this temperature 3 To exit manual mode press once to return to auto To cha...

Page 17: ...0 the tem 19 C until 12 00 w temperature to 21 when it drops to temperature to 21 temperature drop 06 00 when the cy To switch OFF the thermostat Press the and simultaneously for 5 seconds until the OFF is displayed The thermostat and heating system will now be OFF unless the temperature in the controlled space falls below 7 C the frost protection set point Please note this does not affect the ope...

Page 18: ... temperature Set temperature shown flashing 2 After 5 seconds will start controlling at selected set point but displays actual room temperature 2 chrevons indicates override mode 3 To exit override press once or wait until next change in the pre set program 2 Once the time has been set press to confirm and use the or button to adjust required temperature temperature shown flashing 3 Once the tempe...

Page 19: ...or a short ging the temperature in to your new temperature t which time it will revert perature you are setting ure is set the unit will ure The indicator will ned on Event 1 2 3 4 5 6 Time 6 30 8 30 12 00 14 00 16 30 22 30 Temperature 20 0 16 0 16 0 16 0 21 0 7 0 The Digistat 2RF thermostat is a programmable thermostat 24 Hour the same program for every day of the week and allows you to set 6 tim...

Page 20: ...rt below 1 2 3 4 5 6 25ºC 20ºC 15ºC 10ºC 5ºC 06 30 08 30 12 00 14 00 16 30 22 30 Time Period Room Temp As you can see at 06 30 the heating will come on to raise the temperature to 20ºC At 08 30 the temperature set point is dropped from 20ºC down to16ºC it stays at 16ºC throughout the day until 16 30 when the temperature increases to 21ºC The temperature then drops down to a night setback temperatu...

Page 21: ...bol flashing Fig12 pressing any button returns the Digistat 2RF to auto mode allowing normal button operation until the next time temperature event when it will resume the delay start mode or follows the Holiday Manual Override or Off modes as selected Changes to the installer options and pre set programmes must be made with the flame symbol not flashing What is Intelligent delayed start Intellige...

Page 22: ...imingsforyou your programmerwillworkwithastandardprogramthathas beensetatthefactory Ifthisdoesn tsuityou it svery easytochangeit NormalOperation Duringnormaloperationthereceiverwillflashthered LED approximatelyeveryfiveminutes Thisindicatesthata radiosignalisbeingreceivedfromtheDigistattransmitter RadioSignalLoss IftheredLEDdoesnotflashapproximatelyeveryfive minutesthenthereceiverwillshowaflashing...

Page 23: ...together forthreesecondsor longer torestorethedefaultprogramtimestothose showninthetableopposite Switching Weekdays Weekends HW HW 1stON startoffirsttimedperiod 6 30am 7 00am 1stOFF endoffirsttimedperiod 8 30am 9 00am 2ndON startofsecondtimedperiod 12 00pm 12 00pm 2ndOFF endofsecondtimedperiod 12 00pm 12 00pm 3rdON startofthirdtimedperiod 4 30pm 4 00pm 3rdOFF finalswith offoftheday 10 30pm 11 00pm...

Page 24: ...RI 8 30 6 30 UserGuide LP10RFProgrammer Receiver ChangingtheProgram Repeatoperations4to7tosetthesecondandthirdON OFFtimes NOTE Afterpressingset forthethirdhotwaterpre heat OFFtimethedisplayshowsSETMON Settingindividualweekdays NOTE Ifyoudonotrequireindividualweekdaytimes thenpressset untilSETSAT SUNaredisplayed andcontinueonthenextpage Ifyoudonotwish tochangethesettingforthedaydisplayed then press...

Page 25: ...0 PROG SAT SUN SAT SUN SAT SUN PROG PROG PROG 9 00 PROG OFF HW HW ON 9 00 6 30 NOTE Speedupthedisplaybyholdingdownthe or buttons Repeatoperations3to6tosetthesecondandthirdON OFFtimes NOTE Afterpressingset forthethirdhotwaterpre heat offtimeforSAT thedisplaywillshowSETSUN Press OKtosetSUNorpressset untilthedisplayreturns tonormalmode Settingindividualweekenddays NOTE Ifyoudonotrequireindividualweek...

Page 26: ...ndtime 1 Presstheset buttonuntilSETandCLOCK are showninthedisplay 2 PressOKtodisplay24hrandON 3 Press toswitchbetween24hrand12hrdisplay 4 Decidebetween24houror12hourdisplayand pressset toselect nowthehourswillflash 5 Press or tosetthecorrecthour 6 Whenthecorrecthourhasbeenselected press set toselect nowtheminuteswillflash 7 Press or tosetthecorrectminutes 8 Whenthecorrectminuteshavebeenset pressse...

Page 27: ...orrectdayhasbeenchosen pressset toselect nowdLSwillbedisplayedandONwill flash 9 Press or toswitchbetweenONorOFF Ifyou chooseONthentheclockwillautomaticallyadjust thetimeforDaylightsaving IfyouchooseOFF thenthetimewillnotchangetotakeaccountofthe DaylightSavingtimechangetwiceayear J Pressset twicetoreturntothenormaldisplay NOTE dLS DayLightSavingstime DATE DATE DATE MON 36 DATE DATE DATE DATE MON 36...

Page 28: ...06515086001ISSC Support Sales 44 0 845 1305522 Technical 44 0 845 1307722 customer care draytoncontrols co uk www draytoncontrols co uk DraytonHeating DraytonControls ...