- 12 -
GB - Operational mounting regulations
1.
Description
Storage tanks are used for accumulating of excessive heat received from the heat source like, for example, a solid fuel boiler,
a heat pump, solar collectors, fireplace inserts, etc. Some tank types allow connecting more than one heat source at a time.
NAD type storage tanks are used for accumulation of heat in heating systems. Incorporation of the storage tank into a heating
system with a boiler using solid fuel allows for optimum running of the boiler at a favourable temperature during boiler
operation. The benefit comes mainly during the optimum running period (i.e. with maximum effectiveness) when the excess
heat that has not been taken off is accumulated in the tank.
Tanks and also possible pipe exchangers are manufactured from steel with no treatment of the internal surface, the outer
surf
ace has a protective coating. Tanks are equipped with removable 80
mm insulation
- NEODUL LB PP
. Tanks
are manufactured with volumes of 500, 750 and 1000 litres. Individual versions are also equipped with one or two 1.5 m2
pipe exchangers including inspection apertures with an inside diameter of 182 mm with the possibility for installation
of in
-
built TPK electric heating units.
The vessels are not intended for storage of HUW
-
hot utility water.
2.
Basic dimensions
3.
Description of individual versions
NAD v1
Storage tanks can be provided with one to three flanges. The flange with screw gauge 210 mm can be used for mounting
built
-
in TPK flange electric heating units. The flange is blocked off in the standard version. The G
6/4"
extension pipe cab
be used for mounting of the TJ G 6/4"
electric heating unit. Supplied with insulation with a thickness of 80
mm.
NAD v2
Storage tank can be provided with G
6/4"
extension pipe. The G
6/4"
extension pipe cab be used for mounting
of the TJ G 6/4"
electric heating unit. Supplied with insulation with a thickness of 80
mm.
NAD v3
Storage tank with a flange with screw gauge 210 mm and extension pipes or only with extension pipes. The flange
with a screw gauge of 210 mm can be used for mounting built
-
in TPK flange heating units. The flange is blocked
off
in the standard version. Supplied with insulation with a thickness of 80
mm.
NAD v4
Storage tank with a flange with
screw gauge 210 mm for mounting built
-
in TPK flange heating units and one 1.5 m
2
exchanger
for further heating system connection (e.g. SOLAR). The flange is blocked off in the standard version. Supplied with insulation
with a thickness of 80
mm.
NAD v5
Storage tank with a flange with screw gauge 210 mm for mounting built
-
in TPK flange heating units and two 1.5 m
2
exchangers
for further heating system connection (e.g. SOLAR). The flange is blocked off in the standard version. Supplied with insulation
with
a thickness of 80
mm.
Volume [l]
Diameter
[mm]
Height
[mm]
500
600
max. 1974
750
750
2022
1000
850
2035
Summary of Contents for NAD 1000 v1
Page 4: ... 4 4 Zobrazení verzí NAD ...
Page 7: ... 7 4 Przykład wersji NAD ...
Page 10: ... 10 4 Abbildung der Versionen NAD ...
Page 13: ... 13 4 Illustration of NAD versions ...
Page 16: ... 16 4 Az egyes NAD verziók ábrái ...
Page 19: ... 19 4 Изображение серии NAD ...
Page 22: ... 22 4 Visualisation des modèles NAD ...
Page 25: ... 25 4 Zobrazenie verzií NAD ...