6
TROUBLESHOOTING
If the warmer is not operating, check that:
1. The power cable is connected to the power outlet.
2. The water is filled to the proper level.
3. The unit is correctly assembled.
4. If display shows the error “ERR"-"H2O”. The warmer has low water condition. Unplug from power.
Fill water to the correct level. Reconnect to Power.
CLEANING THE WARMER
Daily
1. Unplug the appliance from power.
2. Remove the water reservoir and basket
3. Empty and rinse the warming chamber with clean water. Use mild soap with a damp
cloth or sponge to clean.
DO NOT SUBMERGE UNIT IN WATER!
4. If storing unit for longer than a day, dry or allow to air dry before re-assembly.
14. Press the temperature button to toggle to the sterilizer function.
The unit will default to 6:00.
15. Press the “Cycle Start” button. The timer will count down until
sterilizing is finished.
16. The sterilize cycle is finished when the unit beeps. There is a one minute cooldown period
between when the timer hits 0:00 and when the unit beeps. This allows for the parts to cool
slightly before removal. Take care when opening the lid as there may be some residual steam.
Allow the steam to clear before reaching into the unit. Use the lifting handle to retrieve
small parts.
17. The sterilize feature can be used for any bottle or small part safe for steam sterilization.
USING STERILIZER FEATURE
12. Place small parts or bottle to be sterilized in the warmer basket. When sterilizing Dr. Brown’s
wide neck bottles, place the reservoir tube inside the upside down bottle. Stack the remaining bottle
parts on top of the bottle. Close the lid.
13. With the power connected, press any of the 5 function keys to turn the unit on.
CLEANING THE WARMER (continued)
Monthly (if necessary)
If the warmer heat chamber becomes soiled from milk* or minerals** you may follow these steps:
1. Unplug the appliance from power.
2. Empty water reservoir and basket.
3. Mix 2oz (50mL) of white vinegar with 4oz (100mL) of distilled water in water reservoir.
Please ensure proper ventilation when cleaning with vinegar. DO NOT USE BLEACH!
4. Connect to power. Run a 6 minute warming cycle as normal.
5. Unplug the appliance from power.
6. Remove vinegar and water solution from chamber and reservoir and thoroughly rinse with clean water.
*Remove Dr. Brown’s bottle vent parts to prevent milk leakage into warmer during warming.
**Use only Distilled Water to avoid extra cleaning, damage to warmer and maintain warranty.
WARRANTY
This warming appliance is warranted against defective material or workmanship for a period of one year
from the date of purchase. Any defective part will be repaired or replaced at no charge if it has not been
tampered with and appliance has been used according to these printed instructions. This warranty gives you
specific legal rights as well as other rights which vary from state to state.
To keep your Deluxe Bottle Warmer in good condition and retain your warranty, USE ONLY DISTILLED WATER.
CUSTOMER SERVICE
If you experience unsatisfactory operation or have any questions/comments, call Handi-Craft’s Customer
Service at 1-800-778-9001, send an email to info@handi-craft.com, or write to Handi-Craft Company,
Customer Service, 4433 Fyler Avenue, St. Louis, Missouri 63116 USA. Our Customer Service Representative
will advise you how to correct the problem yourself or will ask you to return the product for repair or
replacement.
FCC COMPLIANCE STATEMENT
This device complies with Part 18 of the FCC Rules, Importer: Handi-Craft Company,
Address: 4433 Fyler Ave., St. Louis, MO 63116
This product has been tested and complies with the requirements for Federal Communications Commission, Part
18 for Radio/TV/Communication interference. Although tested, it may affect these devices. If the bottle warmer is
found to interfere, separate the device and/or the bottle warmer. Conduct only the user maintenance found in this
manual. Other maintenance and servicing can cause harmful interference and can void the required FCC
compliance. If this equipment does cause harmful interference to radio or television reception which can be
determined by turning the equipment off
and on, the user is encouraged to try to correct interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.