Display Messages
OH
“Overheat” (spa is deactivated)
DO NOT ENTER THE WATER. If the spa water has reached
108°F (44°C), Remove the spa cover to cool the water. The spa
will remain shut down until the water and the heater sensor cools
to 104°F. At that point press any button to reset the spa. If the
spa will not reset, shut off the power to the spa and call your
dealer or service organization.
SN
“Non Functional High Temp Sensor” (heater is
deactivated)
Open sensor. Call your dealer or service center.
Equipment System Operation
Initial Start-Up
From the moment your spa is plug in, it is automatically pre-set to
operate until it reaches 100°F. This process could take up to 20 hours
depending on the initial water temperature. The spa is also pre-set to
filter the water for 1 hour per day (
30
) and the clock starts the second
you plug it in.
Temperature Adjustment 60°F-104°F
When either of the “Accu temp pads (
) are pressed once, the
LCD will display the temperature which has been set. Each time either
one of these pads are pressed again, the temperature will change by
1°F. After 5 seconds, the LCD will automatically display the current spa
temperature.
Jets
Press the
pad to run the pump on and off. If left running, the pump
will automatically turn off after 15 minutes.
Light
Press the
pad to turn the spa light on and off. If left on, the light will
automatically turn off after 4 hours.
Spa Water Maintenance
This function enables you to program the amount of water filtration
time.
Press
or
and then
to enter the programing mode.
Once in the programing mode press
or
to select the filtration time.
00
In this mode there is no additional filtration.
30
In this mode the water will be filtered for 1 hour every day.
60
In this mode the water will be filtered for 2 hours every day.
To exit press
Standby Mode
This function allows you to disable the equipment when the filter needs
to be serviced without disturbing the already programed filtration time.
Press
or
and then
to enter the standby mode. All spa functions
are disabled except for freeze control. To exit from standby press any button.
WARNING: SHOCK HAZARD! NO USER SERVICEABLE PARTS. Do not attempt to service this control. Contact your dealer or service
center for assistance. Follow all owner’s manual power connection instructions. Installation must be performed by a certified licensed
electrician and all grounding connections must be properly installed.
WARNING
OPERATING THE SYSTEM WITHOUT WATER
WILL CAUSE SEVERE DAMAGE
OPERATING THE SYSTEM WITH
ANY TYPE OF EXTENSION CORD
WILL CAUSE SEVERE DAMAGE
10
T
EMP
U
P
T
EMP
D
OWN
P
UMP
L
IGHT
T
EMP
D
ISPLAY
Summary of Contents for ECLIPSE
Page 8: ...4 X SPA X CAL ...
Page 11: ...7 ECLIPSE TRIDENT FANTASY GALAXY ODYSSEY ...
Page 12: ...8 X 100 ESCAPE X TREME X 400 X 500 ...
Page 23: ...MAINTENANCE NOTES 19 ...
Page 25: ......
Page 26: ...000781 07 07 ...