29
Instruction ES2007 4/98
Models 4700P and 4700E
87/88 Actuator and 87U/88U Actuator
87/88 Cam
Part No. 041126-183
1
2
3
4
5
6
8
7
1
2
11
10
9
Lever S/A Orientation
Pneumatic Circuit
ARM LEFT
ARM RIGHT
DIRECT
REVERSE
Signal
Supply
Vent
Plug
to
Actuator
Signal
Vent
Plug
Supply
to
Actuator
Valve
Positioner
Range and
Cam
Action
Action
Characteristic
Lobe
Direct
0-100 % Lin
5
Air
0-100 % Perc
2*
Arm
0-50 % Lin
10
to
Right
50-100 % Lin
9
Reverse
0-100 % Lin
11
Open
0-100 % Perc
1*
Arm
0-50 % Lin
4
Left
50-100 % Lin
3
Direct
0-100 % Lin
11
Air
0-100 % Perc
1*
Arm
0-50 % Lin
4
to
Left
50-100 % Lin
3
Reverse
0-100 % Lin
5
Close
0-100 % Perc
2*
Arm
0-50 % Lin
10
Right
50-100 % Lin
9
*Do not use with % valve trim.