SECTION 4
OPERATING
Page 28
OM560C99/1E
DRESSTA
STARTING AND STOPPING THE ENGINE
Allow the engine to run idle for 3 to 5 minutes before placing it under load.
ATTENTION:
Do not run the engine at idle speed more than 10 minutes as it may cause engine
damage.
4.12.2. COLD WEATHER START (USING ETHER INJECTOR, AMBIENT
TEMPERATURE BELOW 0
O
C)
When starting the engine in low temperatures, do as follows:
1. Perform the steps 1 thru 7 of NORMAL START.
2. Move ether injector switch to the ON position for a couple of seconds then release it
immediately. Refer to Fig. 4.2 and 4.3., item 21. Do NOT hold it in the ON position for more than
5 seconds. Ether dose does not depend upon time the switch is held. The switch will return to
neutral position when released.
If the engine does not start, repeat this procedure 2-3 times.This may occur at low ambient
temperatures.
3. When the engine starts, release the ignition key and the key will automatically return to the RUN
position.
ATTENTION:
Never operate ether injector switch except when starting the engine.
WARNING! Ether starting fluid is highly flammable. Follow the precautions on the
container. An explosion can result if sparks or flame contact the ether or if the
container is stored where the temperature exceeds 70
°°
C.
Observe the following precautions:
a) Do not use the ether injector when the air temperature is above freezing.
b) Never smoke when using ether starting fluid or installing the container.
c) Do not store fluid containers in the operator's compartment. Store the
containers in a cool, well-ventilated place.
d) Keep the fluid containers out of reach of children.
e) Do not breathe the hazardous ether vapor.
f) Do not let ether contact your skin, as it can cause frostbite.
g) Never puncture the fluid container or put it into fire. Dispose of empty
containers properly.
h) For your safety, remove the ether container when welding, grinding, or using
a torch on the machine.
I) Follow the correct method for starting the engine.
Do not hold the key in the start position more than 30 seconds. A machine in its standard
configuration is designed for starting in ambient temperatures above –20
°
C. For starting in lower
temperatures special version of wheel loader is needed.
4.12.3. STARTING AFTER OIL CHANGE OR LONGER STORAGE.
When starting the engine after running out of fuel, first fill the fuel tank and then, fill the fuel filter with
fuel before starting.
When starting the engine after each engine oil change or after the engine has been shut off for
more than five days, perform the following steps to insure the engine receives proper lubricating oil
flow through the lubricating system.
1. Perform the steps 1 thru 5 of NORMAL START.
2. Disconnect the electrical wire from the fuel pump solenoid valve.
Summary of Contents for 560C
Page 1: ...OM560C99 1E OPERATOR S MANUAL 560C SERIAL NUMBERS 15001 AND UP ...
Page 3: ......
Page 5: ......
Page 7: ......
Page 10: ...SECTION 1 INTRODUCTION ...
Page 12: ......
Page 16: ...SECTION 2 SAFETY PRECAUTIONS ...
Page 18: ......
Page 32: ...SECTION 3 MACHINE TRANSPORT AND STORAGE ...
Page 34: ......
Page 42: ...SECTION 4 OPERATING ...
Page 43: ......
Page 45: ......
Page 49: ...SECTION 4 OPERATING Page 6 OM560C99 1E DRESSTA UNIVERSAL SYMBOLS FOR INSTRUMENTS AND CONTROLS ...
Page 88: ...SECTION 5 MAINTENANCE ...
Page 141: ...SECTION 6 SPECIFICATIONS ...
Page 143: ......