background image

07-01742C F435-DV (110–230V UK) 

Legend Brands Holdings, Ltd. 

  

 

 
POWER SETUP

 

1. Remove 2 screws on top of moulded 

cover and hinge open. 
2. 

Voltage selection. 

Select 115V or 230V 

on the VOLTAGE SELECTION switch (A).  
3. Plug correctly rated power cord (D) into 

power receptacle (B). (See p. 7 for available 

cords.) 
4. Slide cable strain relief fitting (E) into cord 

grip slot in back panel.  
5. Check that cable is correctly positioned 

into outlet slot and close cover. Close cover 

and replace 2 screws. Tighten fully with a 

wrench. 

 
Reset after incorrect voltage selection: 

The electrical system is internally protected 

against incorrect voltage selection. To reset 

following incorrect connection, disconnect 

the power cord and press the CIRCUIT 

BREAKER button (C). Select correct voltage 

(A) before connecting the power cord. 
 

Replacement 13 amp Fuses for UK power 

cord: 

If the voltage selection switch is set to 115V 

and 230V power is supplied to the unit, the 

breaker may trip and/or the fuse in the UK 

power cord (left) plug may blow. Replace 

with spare fuse (stored in spare fuse box) if 

necessary.  
 

 
 

 

UK power cord fuse 

location (13A / 230V 3 

pin plug #BS1363 only). 

Remove cover to 

replace blown fuse. 

 

 

 

 

UK power cord 

replacement fuses.  

Summary of Contents for BD1000

Page 1: ...odify your BD1000 in any way Use only replacement parts authorized by Dri Eaz Products Modifications or use of unapproved parts could create a hazard and will void your warranty Contact your authorized Dri Eaz distributor for assistance WARNING Unplug before servicing WARNING ELECTRIC SHOCK HAZARD Unplug before opening cover Use with a residual current device RCD where possible Ensure power cord i...

Page 2: ...e handle with supplied screws Nyloc nuts and washers D as shown 5 Close cover and replace 2 screws Tighten fully with a wrench DRAIN HOSE INSTALLATION 1 After opening the housing place hose clamp A over end of interior drain hose B and thread drain hose through hole in rear cabinet wall 2 Insert nipple C into end of drain hose Tighten hose clamp A 3 Exterior drain hose may now be attached to quick...

Page 3: ...h a wrench Reset after incorrect voltage selection The electrical system is internally protected against incorrect voltage selection To reset following incorrect connection disconnect the power cord and press the CIRCUIT BREAKER button C Select correct voltage A before connecting the power cord Replacement 13 amp Fuses for UK power cord If the voltage selection switch is set to 115V and 230V power...

Page 4: ...rocess air outlets IMPORTANT Do not block airflow Control Panel Detail Purge pump button Press and hold to purge pump IMPORTANT To help prevent drip tray overflow after using the dehumidifier always purge the unit before moving 1 Turn the unit off and allow the plugged in dehumidifier to rest for 10 minutes 2 Press the PURGE button Hold until no more water is pumped out of the hose 3 Remove the de...

Page 5: ... LOCATION TOP VIEW COVER OPEN A Hour meter B kW hour meter Storage Transport Store the building dryer vertically If transported horizontally position dryer in normal operating position and leave in place for 30 minutes to allow refrigerant to recirculate before use ...

Page 6: ...d until flanges are released The rivets may then be lifted out of the shroud and the shroud can be removed 5 Vacuum coils C 6 Clean pumpout See Pumpout Cleaning below 7 When finished replace Fan Shroud and Coil Shroud and secure with fasteners Ensure that the power cable and strain relief is correctly positioned into cable outlet slot on chassis Hinge the cover closed Secure cover with 2 screws Pu...

Page 7: ...ds Holdings Ltd 22 Plover Close Interchange Park Newport Pagnell MK16 9PS United Kingdom Tel 44 0 1908 611211 Fax 44 0 1908 611363 SPECIFICATIONS Name Building Dryer BD1000 Model F435 Dimensions W H D 50 51 85 cm Weight 39 kg Water removal AHAM 25 L day 27 C 60 RH Water removal Max 48 L day 32 C 90 RH Water removal EU standard 21 L day 20 C 60 RH Water removal EU standard 42 6 L day 30 C 80 RH Amp...

Reviews: