background image

DR/ EAT

Owner's Manual

Dragon X2 Mobile Furnace (F429)

Air Marketing Group LLC.

141 Kinderkamack Rd, Park Ridge NJ 07656

Phone 201-782-1782 Fax: 201-782-1783 www. amgair com

The Dragon X2 Mobile Furnace is an indirect fired furnace providing  heated air for water damage restoration,

structural drying, construction, event shelters and other temporary heating applications.

READ AND SAVE THESE INSTRUCTIONS

Safety Information

Read this Owner's Manual carefully to learn how to
properly operate and service your Dragon X2 Mobile

Furnace. 

This manual should be kept permanently with

the unit and remain with the Dragon if you sell it.

AWARNING

WARNING! Failure to comply with the instructions
and precautions provided in this Owner's Manual

can result in death, serious bodily injury, andlor
property loss or damage from hazards of fire,
explosion, burn, asphyxiation, carbon monoxide
poisoning, andlor electrical shock.

WARNING! Read this manual carefully before you

use the heater.

• Keep this document near the heater.
• Follow the procedures as written.
• Do not lean or sit on the heater.
• Do not stand closer than 8 ft. (2 m) from the outlet of

the heater.

• Make sure there is sufficient air circulation around

the unit for adequate combustion.

• Keep all flammable material away from the heater.

• Only do repair and 

maintenance after the heater has

cooled sufficiently and the heater is disconnected
from the electric power.

WARNING! Check the Dragon X2 for proper air-to-

fuel ratio before each use. Failure to adjust for

altitude changes could cause injury, permanent

damage to the unit and secondary damage when
ducting into a structure. It may also void the Dri-Eaz
warranty. Refer to -Adjusting for Altitude." p. 4. for
instructions. If you have any questions, please call
Dri-Eaz Service at 800-932-3030.

WARNING! Breathing Hazard

Fuel exhaust contains deadly carbon monoxide gas.
Operate the Dragon only outdoors in open area.
NEVER operate indoors or in enclosed spaces.

WARNING! Fire and Explosion Hazard

• Burner produces sparks and flame and unit

?

"*becomes 

hot 

during use.

.

Keep away from flammable vapors, such as those

from gasoline, paint thinner or solvents.

n

Keep away from combustible dusts, such as coal

dust or sawdust.

• Keep unit at least 8 

ft. 

(2 m) away from any com-

bustible material.

• Keep children and pets away.
• Diesel fuel is flammable and can be explosive.

n

Do not smoke while operating. servicing, or refueling

the Dragon.

• Before refueling, turn unit off, allow to cool and then

unplug.

• Hot surfaces can ignite fuel vapors.

WARNING! Electric Shock Hazard

n

Unit must be grounded. Use only with 3-hole

grounded outlet.

• Never modify plug or use an adaptor. If an extension

cord is needed. it must have a three-prong

grounding plug and be rated for outdoor use.

• Never operate the Dragon in pooled or standing

water. If electrical components become wet, allow to
dry before using.

Product identification
An identification plate is attached to the side of the unit.
The plate shows the year of production, serial number,
electrical supply requirements, airflow, fuel capacity, and
a production code.

9

201-782-1783 Web www amgair corn Email: info@amgair  corn

141 Kinderkamack Rd. Park Ridge, NJ 07656 Tel 201-782-1782 Fax.

Summary of Contents for Dragon X2 F429

Page 1: ...st for altitude changes could cause injury permanent damage to the unit and secondary damage when ducting into a structure It may also void the Dri Eaz warranty Refer to Adjusting for Altitude p 4 for...

Page 2: ...e Dragon may be operated with higher percentages of kerosene up to 100 kerosene but this requires special adjustments Contact Dri Eaz Service at 800 932 3030 for instructions For use in water damage r...

Page 3: ..._ _ r _ 7 a 7 7 2 _ 11 _ 1 _ 1 1 1 _ _ 1 _ _ _ _ man 1 1 w m _ _ _ _ 1 _ _ Tr _ El r ar r 2 _ _ 1 7 n _ _...

Page 4: ...ine follow these steps Supplies needed Yi in i d x 6 ft clear plastic hose receptacle for fuel rags or cloths to clean up any spills wrenches and screwdriver 1 Turn the CONTROL KNOB to the Off positio...

Page 5: ...uel If the Dragon runs out of fuel a fuel cutoff sensor will automatically shut the heater off and the BURNER CONTROL BUTTON Fig 1 G will glow red The fan may continue to cycle on and off until coolin...

Page 6: ...peration these components should be inspected once a year and cleaned if necessary by a qualified HVAC technician Contact your local distributor or the Dri Eaz Service Department at 800 932 3030 for t...

Page 7: ...culaciOn de aire alrededor de la unidad para clue la combustiOn sea adecuada Mantenge todos los elementos infiamables lejos del calentador Hap tareas de reparacion y mantenimiento unicamente cuando el...

Page 8: ...danos causados par el ague y secar construcciones nuevas el Dragon puede aumentar la eficacia de secado El calor que aporta el Dragon aumentara el indice de evaporacien al disminuir la humedad relati...

Page 9: ...nolque de su vehiculo Para evitar movimientos inesperados asi como posibles Janos y lesiones coloque sienripre tacos en las ruedas cuando estacione el rernolque Antes de cada viaje realice un control...

Page 10: ...ra que haya en la estructura per ejemplo la ventana de un sotano o el bloque de ventilacion de un entresuelo Dada que cada estructura es Unica por le general tendra que crear un adaptador que se adecu...

Page 11: ...ara funcionar en alturas que van desde el nivel del mar haste los 5000 pies 1500 m Para garantizar el correcto funcionamiento y el maxima rendimiento en lugares de gran altura es necesario ajustar la...

Page 12: ...e y se detenga en forma internnitente haste que termine de enfriarse Siga estas instrucciones pare reiniciar la unidad Consejo Puede ser necesario repetir este operacian ties o cuatro veces haste que...

Page 13: ...linea de combustible en la pagina 11 3 Mantenimiento del quemador Junto con la documentacien sabre el Dragon se incluyen copias del AFIAFG Oil Burner Manual Manual del quemador de fueloleo modelo AF A...

Page 14: ...bustible indice de consumo de combustible 0 8 gaVh I 3 1 h PresiOn de la bombe de combustible 1 40 lb n2 I 966 kPa Segundad Certificacion de ETL conforme a CSA S140 8 1967 Reaffirmed 2001 Portable Ind...

Page 15: ...du generateur La circulation d air autour de l apparell doit favoriser une bonne combustion Garder eloignees du generateur toutes les matieres inflammables Avant toute reparation cu tout entretien tai...

Page 16: ...geant un chauffage temporaire sec et propre Le Dragon favorise on sechage plus efficace lors dune refection dommages causes par l eau ou dun nouveau travail du batiment En effet la chaleur d appoint d...

Page 17: ...referer aux normes CSA B139 et CSA B140 1962 Avitaillement Le Dragon est livre avec un reservoir de carburant vide Faire le plein avant la mise en service de diesel ou de fuel oil lourd n 1 ou n 2 Par...

Page 18: ...eur de ce dernier clans la zone cible puis mettre le BOUTON DE COMMANDE sur Thermostat MISE EN GARDE Verifier les A reglages du Dragon et les conditions dans la structure au moms une fois par Jour de...

Page 19: ...ee blanche en revanche ternoigne dun m lange pauvre exces d air ou de la presence d eau dans le carburant Suivre les tapes suivantes de reglage du m lange lorsque la fumee est blanche ou noire a Un ch...

Page 20: ...ieurs tentatives contacter le service technique de Dri Eaz au 800 932 3030 AVIS Le Dragon doit faire I objet dun examen visuel au moms une fois par jour de fonctionnement Regarder s il n y a pas de fu...

Page 21: ...r et 8 po de diametre 7 6 m x 20 cm Une extrennite de _ chaque game est munie Tune manchette cousue avec ceinture et boucle integrees 1 thermostat avec cordon de capteur de 60 pi 18 3 m 1 Guide d util...

Page 22: ...na 23 la explicacion de los simbolos utilizados en el esquema Voir tegende du schema p 23 1 4 51 V 111 3 iv a f X4KINI i l l Ch I T Air Marketing Group LW 141 Kinclerkarnack Rd Park Ridge NJ 07656 Tel...

Page 23: ...3 SJT FAISCEAU DE CABLES 241 AC 24VAC 24 V c a BLOWER VENTILADOR SOUFFLANTE BULB BOMBILLA AMPOULE BURNER QUEMADOR BRCJLEUR BURNER CONTROL SVVITCH 1ADJUST TO 155 F INTERRUPTOR DE CONTROL DEL QUEMADOR L...

Reviews: