background image

49-043 F 2011-06 Warranty 07-00424 

Dri-Eaz Products, Inc. 

because the heater does not yet have sufficient fuel 
to operate.  

6.  If the burner has not started after the third attempt, 

the burner control light will flash red. To reset, press 
and hold the BURNER RESET BUTTON for 15 
seconds until the light goes out. Now you may repeat 
steps 2–5 as necessary until the burner ignites.  

Tip:

 If the unit will not restart after several attempts, 

contact Dri-Eaz Service at 800-932-3030.  

NOTICE:

 You should continue to physically check the 

Dragon at least once a day during operation. Check for 
leaks, and observe the exhaust smoke to ensure that it’s 
still clear.  

CAUTION:

 Always use clean fuel and a trusted fuel 

source to prevent fuel problems. Be sure to replace the 
fuel tank cap to prevent moisture or contaminants from 
getting into the fuel. 

M A I N T E N A N C E

 

Recommended Maintenance Intervals 

NOTICE: Always turn unit off and unplug before 
performing any maintenance. 
 

D E S C R I P T I O N

 

I N T E R V A L

 

1. Clean the fuel tank.  

Yearly 

2. Replace the fuel filter.  

Yearly 

3. Service the burner.  

Refer to  

manufacturer’s manual. 

4. Inspect the heat exchanger.  

Yearly 

 
1. Cleaning the fuel tank.  

The fuel tank should be cleaned out once a year. To 
clean the tank, follow these steps: 

a. Place an appropriate container beneath the drain 

plug to catch any fuel. 

b. Remove the drain plug with a wrench. 
c. Allow the tank to drain completely.  
d. Replace the drain plug.  
e. Dispose of waste fuel in accordance with local 

regulations. 

 
WARNING! Diesel fuel and diesel/kerosene mixtures 
are flammable and potentially explosive. Always turn 
off and unplug the Dragon before draining the fuel 
tank. Do not smoke while draining fuel. Keep away 
from open flame.

 

 
2. Replace the fuel filter 

Replace the fuel filter once a year. The filter is a spin-on 
type and is located inside the right side cabinet behind 
the control panel. Replacement fuel filters may be 
purchased from Johnston Supply, part no. L41-653. Visit 

www.johnstonesupply.com

 to locate the nearest 

Johnstone dealer. Have rags or paper towels on hand to 
clean up any spills, and dispose of the filter and waste 
fuel according to local regulations. You must bleed all air 
from the fuel lines and allow the filter to fill with fuel 
before the burner will ignite. See “Bleeding the fuel line,” 
p. 4.  

3. Servicing the burner 

Copies of the 

AF/AFG Oil Burner Manual

 and the 

GeniSys Model 7505 Advanced Burner Control Manual

published by R.W. Becket Corporation, are included with 
your Dragon documentation. Please refer to these 
documents for information about servicing the burner.  

4. Servicing the heat exchanger and combustion 
chamber  

In time, soot may accumulate in the the heat exchanger 
and combustion chamber. To ensure proper operation, 
these components should be inspected once a year and 
cleaned if necessary by a qualified HVAC technician. 
Contact your local distributor or the Dri-Eaz Service 
Department at 800-932-3030 for the location of a service 
center near you. 

5. Cleaning the housing 

To clean the Dragon housing, use a cleaner with a 
degreasing agent such as Unsmoke Degrease-All. 

Accessories Included 

3  25 ft. sections of 8 in. (7.6 m × 20 cm) high-

temperature ducting. One end of each duct is fitted 
with a sewn-in cuff and integrated belt and buckle.  

1  thermostat with 60 ft. (18.3 m) sensor cord. 
1  Owner’s Manual (Dri-Eaz) 

AF/AFG Oil Burner Manual

 (Becket)  

GeniSys Model 7505 Advanced Burner Control 
Manual

 (Becket) 

Service 

For parts and service call your local distributor or the 
Dri-Eaz Service Department at 800-932-3030 or 
360-757-7776. Copies of the Dragon manual and related 
information are available at 

www.Dri-Eaz.com. 

Go to 

warranty.Dri-Eaz.com

 to register your purchase.  

Summary of Contents for Dragon X2

Page 1: ...o before each use Failure to adjust for altitude changes could cause injury permanent damage to the unit and secondary damage when ducting into a structure It may also void the Dri Eaz warranty Refer...

Page 2: ...on Fuel type The Dragon X2 Mobile Furnace can operate for approxi mately 72 hours on a single tank depending on conditions The Dragon is designed to operate on no 1 or no 2 diesel or fuel oil In cold...

Page 3: ...tack to the flue opening by slipping the stack over the flue ring Figure 1 B If the stack does not fit snugly drive small sheet metal screws into the three pre drilled holes in the base of the stack t...

Page 4: ...e could damage the heat exchanger and will not be covered under warranty Special Instructions Bleeding the fuel line In certain circumstances air may accumulate in the fuel line and prevent proper ope...

Page 5: ...eset To manually reset the Dragon after a thermal overload shutoff 1 Open the hood by removing sheet metal screws and lifting The hood is hinged on one side 2 Turn the CONTROL KNOB to Thermostat 4 Pre...

Page 6: ...Replace the fuel filter once a year The filter is a spin on type and is located inside the right side cabinet behind the control panel Replacement fuel filters may be purchased from Johnston Supply p...

Page 7: ...hut off monitored by thermostat 102 F 38 8 C Automatic reset cut off No user intervention required 175 F 79 4 C High temperature cut off Manual reset required 205 F 96 1 C Fuel tank capacity 55 gal 20...

Page 8: ...e pare a menos de 8 pies 2 m de la salida del calentador Aseg rese de que haya suficiente circulaci n de aire alrededor de la unidad para que la combusti n sea adecuada Mantenga todos los elementos in...

Page 9: ...e temporalmente calor puro y seco Cuando se utiliza para reparar da os causados por el agua y secar construcciones nuevas el Dragon puede aumentar la eficacia de secado El calor que aporta el Dragon a...

Page 10: ...s ruedas cuando estacione el remolque Antes de cada viaje realice un control de seguridad del remolque Aseg rese de que La bola de remolque est bien colocada en el recibidor y el pasador de seguridad...

Page 11: ...te el tubo al transportar el Dragon ADVERTENCIA No utilice el Dragon si el tubo de escape no est colocado Coloque los conductos en el Dragon El Dragon incluye tres conductos de 25 pies de largo por 8...

Page 12: ...0 5 cm x 2 m recipiente para combustible trapos o pa os para limpiar cualquier derrame llaves de tuercas y destornillador 1 Gire la PERILLA DE CONTROL hasta la posici n Off 2 Abra la tapa Aseg rese d...

Page 13: ...ragon volver a funcionar con normalidad Para mayor seguridad el Dragon tambi n incluye un limitador de alta temperatura Si el intercambiador t rmico alcanza los 205 F 96 1 C el limitador apagar el Dra...

Page 14: ...drenaje para que caiga all el combustible b Quite el tap n de drenaje con una llave de tuerca c Deje que el tanque se vac e por completo d Vuelva a colocar el tap n de drenaje e Deseche el combustible...

Page 15: ...delo Calentador Port til Dragon X2 Portable Heater F429 Dimensiones con el remolque incluido ancho x altura x profundidad 74 54 116 in 1 9 1 4 3 m Peso 1500 lb 680 kg Peso total del veh culo 2000 lb 9...

Page 16: ...as se pencher ni s asseoir sur le g n rateur Ne pas s approcher moins de 8 pi 2 m de la sortie d air du g n rateur La circulation d air autour de l appareil doit favoriser une bonne combustion Garder...

Page 17: ...ocaux de stockage et les entrep ts les serres et les tunnels en polyur thanne pour l agriculture toute situation exigeant un chauffage temporaire sec et propre Le Dragon favorise un s chage plus effic...

Page 18: ...r un endroit non fr quent par les enfants ou les animaux V rifier que l entr e d air est bien d gag e MISE EN GARDE Les prises d air doivent tre propres sans engorgement viter de placer l appareil l o...

Page 19: ...es r glages du Dragon et les conditions dans la structure au moins une fois par jour de fonctionnement R gulation de la temp rature Le Dragon est muni d un thermostat distant permettant de r guler la...

Page 20: ...arburant L chappement du Dragon doit toujours tre transparent Une fum e noire ou blanche indique un mauvais m lange air carburant a Lorsque l chappement est transparent aucun r glage n est n cessaire...

Page 21: ...u refroidissement complet du g n rateur Suivre les instructions ci apr s de red marrage Conseil Les tapes suivantes doivent parfois tre r p t es trois quatre fois afin de permettre la pompe de carbura...

Page 22: ...service technique de Dri Eaz au 800 932 3030 l adresse du service apr s vente le plus proche 5 Nettoyage du bo tier Nettoyer le bo tier du Dragon avec un d graissant de type Unsmoke Degrease All Acces...

Page 23: ...1 06 Warranty 07 00424 23 Dri Eaz Products Inc Dragon X2 Schematic Esquema Schematic See Schematic Key p 24 Vea en la p gina 24 la explicaci n de los s mbolos utilizados en el esquema Voir l gende du...

Page 24: ...3 SJT CONJUNTO DE CABLES DEL TERMOSTATO 14 3 SJT FAISCEAU DE C BLES 24VAC 24VAC 24 V c a BLOWER VENTILADOR SOUFFLANTE BULB BOMBILLA AMPOULE BURNER QUEMADOR BR LEUR BURNER CONTROL SWITCH ADJUST TO 175...

Reviews: