49-109H F533
6
Dri-Eaz Products, Inc.
TRANSPORTATION AND STORAGE
NOTICE:
Handle the unit carefully. Rough treatment can
damage this equipment and may create a hazardous con-
dition or void warranty.
Do not expose the control panel to moisture, snow or
rain.
Store and transport securely to avoid any damaging
impact to internal parts.
Secure during transport to prevent sliding and possi-
ble injury to vehicle occupants.
MAINTENANCE
WARNING! ELECTRIC SHOCK HAZARD.
Unplug unit
before cleaning or servicing
.
WARNING: Risk of dust and contaminants exposure.
Use of respirator mask and gloves is recommended. If
unit has been exposed to potentially dangerous con-
taminants, clean thoroughly and disinfect before re-
use.
As Needed (Exterior items)
Inspect filter.
Replace if accumulation of dust and debris
is visible.
NOTICE: Replace used filters only with a new Dri-Eaz
filter part no. F590 (24-pack). Other filter types do not
provide adequate filtration or airflow. Each filter is in-
dividually wrapped to protect filtration effectiveness.
Remove the wrapper before installing the filter into
the dehumidifier.
To maintain appearance
, wipe interior and exterior sur-
faces with a damp cloth.
Inspect reactivation air outlet ducting for cracks, splits or
breaks. Replace as needed with suitable heat-resistant
ducting.
As Needed (Interior items) See Fig. D.
NOTICE:
Electric shock hazard. Unplug unit before re-
moving side panels.
NOTICE:
The unit is fitted with sensitive electronic sen-
sors. Protect the sensors and their lead wires from dam-
age and do not expose them to water or cleaning solution.
The following tools and supplies are needed to complete
the maintenance procedures described in this manual:
3 mm Allen wrench and/or bit and cordless drill
Clean cloths
Vacuum cleaner with soft brush tool and/or a high
pressure air nozzle
Remove side panel.
Remove the screws from the react
out / air inlet panel.
IMPORTANT: The inlet temp/RH
sensor cable is attached to the interior of the panel
and must be detached before setting the panel aside.
To remove the cable, first unclip the plug and then slide
the cable down and out of the cable tie. Once the cable is
free of the panel, set the panel aside.
Fig. D: Interior views
Blower
Storage compart-
ment.
React out/air in panel.
Remove this panel
only for routine inte-
rior inspection and
cleaning.
IMPORTANT! Temp/RH
Sensor cable is attached
to inside of panel! Unclip
and slide out of cable tie
before setting panel
aside.
Detach sensor cable be-
fore setting side panel
aside. Be sure to rein-
stall cable when replac-
ing panel.
Desiccant
rotor
React air
outlet
Belt tensioner
(see detail be-
low)
Belt tensioner.
Lift arm upward
to release belt.