49-109H F533
9
Dri-Eaz Products, Inc.
TROUBLESHOOTING
F A U L T
C A U S E
S O L U T I O N
Separate circuit in-
dicator light does
not illuminate
Unit not plugged into two sepa-
rate circuits.
Incorrect wiring in the building.
Plug unit into two separate circuits rated for at least 15
amps each.
Locate a second 15 amp circuit in the structure.
Circuit breaker trips
after a few minutes
of operation.
Reactivation outlet not ducted.
Ducting is kinked or blocked.
Excessively long ducting.
The Reactivation Out must always be ducted out of the
area being ducted.
Straighten all ducting as much as possible; remove any
blockages.
React ducting length should not exceed 20 ft. (6 m).
Unit does not oper-
ate
Unit not switched on.
No power to machine.
Switch unit on.
Check power cord connections at wall outlet and in top
compartment of unit. Check supply circuit breakers.
Unit operating, but
room not dry
Not enough time to dry.
Poor air movement in room.
Excessive moist air infiltration.
Allow more time for drying.
Increase evaporation with air movers.
Seal off area to reduce infiltration.
Unit removes too
little water
Room air is dry.
Inlet air temperature is too warm.
Inlet air temperature is too damp.
Filter is clogged.
Confirm humidity level with hygrometer.
Decrease temperature of intake air.
Decrease humidity of intake air.
Check filter. Clean or replace as necessary.
If the problem you are experiencing is not listed here, call your local distributor or contact
our Service Department toll-free at 800-932-3030 for further assistance.
SPECIFICATIONS
Power
115V / 60 Hz
Amps (max.)
24
Amps (at 80°F/60%RH)
Circuit 1: 10.7
Circuit 2: 10.8
Process air
395 CFM
Reactivation air
65 CFM
Water removal
(at 80°F/60%RH)
118 pints/day | 55.8 L per/day
Weight
95 lbs. | 43.1 kg
Dimensions (H × W × D)
33.13 × 21.14 × 20.25 in.
(With handle upright = 42. 250 in.)
84.15 × 53.7 × 51.4 cm
(With handle upright = 107.3 cm.)
Air filter
F590 (24 pk)
Safety
ETL listed to CSA dehumidifier
standards
WARNING
: This product may expose you to
chemicals, including lead and phthalates, known
to the State of California to cause cancer, birth defects,
or other reproductive harm. For more information, go to
P65Warnings.ca.gov
PARTS INCLUDED
Reactivation Out duct ring adapter
Reactivation Out heat-resistant ducting, 20 ft. × 6 in.
6 in. duct clamp
Air inlet duct ring adapter (optional, installation requi-
red)
Process air outlet layflat duct adaptor kit (optional,
installation required)
Two power cords, 25 ft. each
OPTIONAL
Layflat ducting for process air outlet (F536)
ADDITIONAL PRODUCT INFORMATION
and current
documentation is available at
www.LegendBrandsResto-
ration.com
.
FOR PARTS AND SERVICE CALL YOUR LOCAL DIS-
TRIBUTOR
or Dri-Eaz at 800-932-3030.
www.Legend-
BrandsRestoration.com
Visit
warranty.LegendBrandsRestoration.com
and regis-
ter your purchase to ensure you receive any important
product releases.