background image

 

07-00265 G  12-02  Copyright 2000, 2002 Dri-Eaz Products, Inc. 

 

Owner’s Manual – DrizAir Dehumidifier 

DrizAir 80 

115-volt models

 

DRI-EAZ PRODUCTS, INC.  

15180 Josh Wilson Road, Burlington, WA USA 98233 

Fax: (360) 757-7950  Phone: (360) 757-7776   www.dri-eaz.com  

DrizAir Dehumidifiers are commercial refrigerant dehumidifiers, designed for drying building structures  

and contents. They are designed for high performance water removal, as well as durability and ease of use. 

Read And Save These Instructions 

 

  

Safety Information

 

Keep Children Away:

 Do not allow children to play with or 

around the unit, which could result in injury. Be sure the unit is 
inaccessible to children when not attended. 

Keep Unit Grounded

: Always operate the unit with a grounding 

plug and a grounded electrical outlet. A grounding plug is an 
essential safety feature that helps reduce the risk of shock or 
fire. 

Protect Power Cord from Damage:

 Never operate a unit with a 

damaged power cord, as this may lead to electrical or fire haz-
ards. If the power supply cord is damaged, it must be replaced 
by a cord of the same type and amperage rating. 

Extension Cords:

 Extension cords must be grounded and able 

to deliver the appropriate voltage to the unit. 

Handle With Care:

 Do not drop or throw the unit. Rough treat-

ment can damage the components or wiring and create a haz-
ardous condition. 

Run on Stable Surface:

 Always operate the unit on a stable, 

level surface, like the floor or a strong counter, so it cannot fall 
and cause injury. 

Secure During Transport:

 When transporting in a vehicle, se-

cure the unit to prevent sliding and possible injury to vehicle oc-
cupants. 

Keep Out of Water:

 Never operate the unit in pooled or standing 

water, as this may create a risk of injury from electrical shock. Do 
not store or operate outdoors. If electrical wiring or components 
become wet, thoroughly dry them before using the unit.

  

Keep Air Intakes Clear:

 Do not clog or block air intakes, as may 

occur if operated to close to draperies or similar materials. This 
may cause the unit to overheat and result in a fire or electrical 
hazard. 

Keep Filter Clean: 

Always use a clean air filter. Do not allow 

any material to clog the filter, as this may cause the dehumidifier 
to overheat. Do not allow oil, grease, or other contaminants to be 
drawn into the dehumidifier.  

Keep Electrical Components Dry:

 Never allow water inside the 

dehumidifier's electrical components. If these areas become wet 
for any reason, thoroughly dry them before using the dehu-
midifier. 

Allow Repair Only by Qualified Person:

 Do not attempt to dis-

assemble or repair the unit if you are not qualified to do so. You 
may handle some maintenance and troubleshooting, but make 
sure that more complex problems are handled by an authorized 
service technician. For information about authorized repair, call 
Dri-Eaz at (360) 757-7776. 

HOW TO USE DEHUMIDIFIERS  

DrizAir Dehumidifiers are designed to reduce water vapor or high 
humidity in a building or part of a building. The purpose is to pre-
vent humidity damage, and to dry out wet materials such as car-
pet, carpet cushion, floors, walls, furniture, contents, lumber, and 
structural materials.  
To speed up the rate of evaporation, and dry out materials faster, 
use Dri-Eaz TurboDryer airmovers. The DrizAir Dehumidifier will 
be needed to remove the additional water evaporated by the 
TurboDryers. 

Positioning Dehumidifiers 

The dehumidifier must be operated in an enclosed area to 
achieve best efficiency. Close all openings to other areas of the 
building, like windows and doors, to prevent moist air from mix-
ing with the air in the drying area. Keep traffic through doors at a 
minimum. This forms a closed drying chamber. 
Inside the drying chamber, air should circulate freely. Open inte-
rior doors and operate TurboDryer airmovers to maintain good 
airflow to all areas. 
Place the dehumidifier where there is no restriction to air flowing 
through either the inlet or the outlet. Keep away from loose mate-
rials like curtains and drapes. 
Under normal circumstances, place the dehumidifier in the cen-
ter of the room. To dry a specific area, place the dehumidifier so 
the outlet air points at the wet area and the warm, dry air passes 
across it. The duct should never be closer than three feet from 
the wall. 
The DrizAir Dehumidifier warms the air as it removes its mois-
ture. In smaller rooms this can raise the temperature substan-
tially. Room temperatures of about 68° to 80° F (20° to 27° C) 
are usually a good condition for drying. Never allow the room 
temperature to exceed 100° F (38° C), because this could dam-
age the dehumidifier or building contents. 

OPERATING INSTRUCTIONS 

1.  Operate the DrizAir Dehumidifier only in the upright position. 

If it has been in a horizontal position for any time over a few 
minutes, let it sit in the upright position for at least 30 minutes 
before starting. This allows oil to drain back into the com-
pressor, increasing its life. 

2.  Plug in to a standard outlet with the correct voltage and am-

perage for the unit. Push the ON switch. Listen for proper 
operation of fan and compressor before leaving the unit unat-
tended. 

3. 

Allow five minutes before restarting

 after the unit shuts off 

for any reason. This will avoid damaging the compressor. 

4.  If your unit has a pump, run the pump drain hose into a sink, 

toilet, drain, or bucket. Make sure the hose is not kinked. If 

Summary of Contents for DrizAir 80

Page 1: ...r repair the unit if you are not qualified to do so You may handle some maintenance and troubleshooting but make sure that more complex problems are handled by an authorized service technician For information about authorized repair call Dri Eaz at 360 757 7776 HOW TO USE DEHUMIDIFIERS DrizAir Dehumidifiers are designed to reduce water vapor or high humidity in a building or part of a building The...

Page 2: ...wires insecure fasteners and discoloration Remove and repair any damaged wiring as needed Failure to do so may lead to electrical shock or a fire hazard PUMP TUBE Make sure the pump tube is completely un wrapped and not kinked Failure to do so can cause water to back up in the pump and leak out The control panel may signal this problem by displaying ER9 KEEP OUT DUST Keep dust from drywall demolit...

Page 3: ...ng AST Contact distributor or Dri Eaz Products Blower wheel not turning Obstructed blower FS Remove obstruction Loose blower wheel set screw FS Tighten set screw Loose or broken wire AST Replace broken wire Burned out fan motor AST Replace fan motor Dehumidifier operating Not enough time to dry FS Allow more time for drying but room not dry Poor air movement FS Increase air movement with TurboDrye...

Page 4: ...nts électriques du déshumidificateur Si jamais ils arrivaient à être mouillés sé chez les entièrement avant d utiliser l unité Faites seulement réparer par une personne qualifiée N essayez pas de démonter ou de réparer l unité si vous n êtes pas qualifié pour le faire Vous pourrez effectuer certains entre tiens et dépannages mais assurez vous que les problèmes plus complexes soient réglés par un r...

Page 5: ...ctriques dénudés des décolorations et des éléments de fixation détachés à l intérieur du câblage Enlevez et réparez tout câblage endom magé si nécessaire Le non respect de ces mesures pourra en traîner des risques d électrocution ou d incendie TUBE DE POMPE Vérifiez que le tube de la pompe est en tièrement déballé et qu il n est pas tordu En l absence de vérifica tion l eau pourrait remonter dans ...

Page 6: ...obstrué ST Enlevez l obstruction pas Vis sans tête de la roue desserrée ST Serrez la vis sans tête Fil électrique cassé ou lâche TEA Remplacez le fil électrique cassé Moteur du ventilateur grillé TEA Remplacez le moteur du ventilateur Le déshumidificateur marche Pas assez de temps pour sécher ST Laissez plus de temps pour sécher mais la pièce n est pas sèche Mouvement d air insuffisant ST Augmente...

Page 7: ... no permita nun ca que entre agua en los componentes eléctricos del deshu midificador Si estas zonas se mojan por cualquier motivo sé quelas completamente antes de utilizar el deshumidificador Únicamente personal autorizado para las reparaciones no intente desmontar ni reparar la unidad si no está cualificado para ello Usted puede solucionar algunos problemas o cuestiones de mantenimiento pero ase...

Page 8: ...robar que no ha sufrido daños Reti re periódicamente la carcasa y examine los cables internos para ver si hay cables pelados cierres inseguros o decoloración Reti re y repare los cables dañados cuando sea necesario De no hacer lo podrían provocarse descargas eléctricas o peligro de incendios TUBO DE BOMBA Asegúrese que el tubo de la bomba esté completamente desembalado y sin retorcer De lo contrar...

Page 9: ...to con el distribuidor o con Dri Eaz Pro ducts La rueda del ventilador no gira Ventilador obstruido SC Retire el elemento que obstruye Tornillo de la rueda del ventilador suelto SC Apriete el tornillo Cable suelto o roto TSA Sustituya el cable roto Motor del ventilador quemado TSA Sustituya el motor del ventilador El deshumidificador funciona El tiempo no es suficiente para secar SC Deje más tiemp...

Reviews: