Electrical Outlets 

Connect up to eight (8) HEPA 700s on a 15-amp circuit on 
the lowest speed; four (4) on the highest speed. 

COMMAND HUB: HOME 

 On/Off. 

Switches unit on or off.  

 Speed control

 to adjust blower speed. 

 Menu.

 Select to view system info, service, error 

messages, wireless setup and other information.  

MAINTENANCE 

About the filters 

IMPORTANT: Use Legend Brands HEPA 700 filters only 
(see Filter Options below). Using other filters will reduce 
filtration effectiveness. 

Regularly check and replace the prefilter(s) and HEPA 
primary filter as needed. Control panel indicates when 
the HEPA primary filter needs to be replaced. Do not 
attempt to clean and reuse filters.  

NOTICE: When using the HEPA 700 on remediation 
projects, change BOTH filters after every job. Dispose of 
contaminated filters per local, state and federal 
regulations.  

Replacing the Prefilter 

When using the unit in environments with a high volume of 
airborne particles, the prefilter should be replaced more 
frequently to help preserve the life of the HEPA filter.  

1. Lay unit on its back and release the four (4) buckles. Lift off 

the filter door.   

2. Remove the prefilter from the filter door and discard. 
3. Insert new prefilter into filter door. Ensure that the prefilter is 

seated properly on the retention tabs.  

4. Replace filter assembly on unit and reattach four buckles. 

 

 

Replacing the HEPA Primary Filter 

IMPORTANT:

 Performance is reduced when a non-Legend 

Brands primary filter is installed. For maximum filtration 
performance, use only Legend Brands filters. Do not clean and 
reuse the HEPA filter. Always replace the prefilter when 
replacing the HEPA filter. 

1.  Lay unit on its back and release the four (4) buckles. Lift 

off the filter door.   

2.  Remove the prefilter from the filter door and discard. 
3.  Replace HEPA primary filter, handling it with care, as filter 

is easily damaged. Do not use a filter that is damaged. 

4.  Place new prefilter(s) in filter door. Replace filter cover and 

lock the four buckles securely. 

Regulatory approvals - ATWINC3400-MR210CA modules: 

 

United States/FCC ID:  2ADHKWINC3400 

 

Canada/ISED: 

o

 

IC: 20266-ATWINC3400 

o

 

HVIN: ATWINC3400-MR210CA 

o

 

PMN: Wi-Fi and Bluetooth Module 

Filter Options 

Air Filtration Applications:

 

Prefilter(s)

 

Removes larger 

particulates 

– protects 

primary filter 

Specialty Prefilter

 

Carbon removes 
VOCs and odors 

Primary filter (HEPA)

 

Removes fine particulate 

down to .3 microns 

 

Water loss air filtration and mold 
remediation*

 

 

Standard air scrubbing.

 For high particle 

loads, such as construction or remodeling sites.

 

2-in. MERV 8 Pleated 

Paper Filter 

#125026 (6 pk.) 

 

HEPA Filter 

#124966 (1 pk.)  
#125028 (8 pk.) 

 

Odor control and air filtration.

 For removing 

volatile organic compounds (VOCs), fumes from 
paint and paint thinners, and many other 
noxious odors, eg, from food, sewage, etc. 

 

Smoke particulate and odor removal.

 Paper 

prefilter and HEPA filter remove particulates 
and carbon filter adsorbs odors.

 

1-in. MERV 8 Pleated 

Paper Filter 

#125029 (12 pk.) 

1-in. Activated  

Carbon Filter 

#125027 (4 pk.) 

HEPA Filter 

#124966 (1 pk.)  
#125028 (8 pk.) 

See Owner’s Manual for asbestos remediation guidance.

 

 

For parts and service, contact your local dealer or Legend Brands, 15180 Josh Wilson Rd., Burlington, WA  98233 

Live Chat:  Info.legendbrands.com | Email

Service@legendbrandsrestoration.com

 | Phone:  800-932-3030 

Changing Filters 

HEPA filter 
locking tabs 

Filter cover 

Prefilter Option 1: 

One 2-inch filter  

Filter cover  
buckles (×4)  

Prefilter Option 2:  

Two 1-inch filters 

Secure replacement prefilter(s) 
into notched tabs (×4) 

HEPA filter  