Drifton Liquid Dispenser for Barrels 

 

Operation Manual (GB) 

 

Drifton 2000-D 

 

 

 

 

Summary of Contents for 2000-D

Page 1: ...S Avedoereholmen 84 2650 Hvidovre Denmark TEL 0045 5372 8090 FAX 0045 3677 3633 Website www drifton eu www drifton dk E mail info drifton dk Drifton Liquid Dispenser for Barrels Operation Manual GB Drifton 2000 D ...

Page 2: ...d testing procedures Review the helpful information we have included which is based on more years of industrial dispensing experience Most questions you will have are answered in this Operation Manual However if you need assistance please do not hesitate to contact Drifton A S at telephone 0045 5372 8090 or info drifton dk or an authorized distributor Our goal is to build not only the finest equip...

Page 3: ...ic System 10 For your safety please read this operation manual carefully before operating And always keep this manual within reach Automatic Liquid Dispenser with time control to push the liquid pneumatically controlled by timer to be sure of the same dispensing drops and dispensing cycle time Regulate the air pressure with suitable tip on your equipments with the different liquids such as glues g...

Page 4: ...iation Maintained or Momentary Maintained or Momentary Auto Repair 3 Repeat Tolerance 0 5 4 Size 235 x 225 x 63mm 5 Weight 2 20kg 6 Voltage Input 220 240V 50 Hz AC 7 Internal Voltage 24V DC 8 Minimum Deposit 0 01ml 9 Air Input 2 5 7 bar 35 100 psi 10 Air Output 0 01 5 5 bar 1 78 psi ...

Page 5: ...he dispense circuit in automatic or manual shot mode c B 2000A Places the dispense circuit in automatic or manual shot mode 4 Timer Control Adjust the shot of the Auto dispense mode 5 Vacuum Control Adjust the intensity of suck back vacuum applied to the dispense circuit 6 Dispense Outlet Provide a quick connect receptacle for dispense air circuit 7 Foot switch Activates the dispense circuit 8 Air...

Page 6: ... settings on the drip switch can be applied as the following table TIMED MODE 0 01s 0 06s 0 16s 0 26s S1 ON ON ON ON S2 OFF ON ON ON S3 OFF OFF ON ON S4 OFF OFF OFF ON Dotting range regulated Time range can be regulated on the time table knob Every dot 1s min reach to the max 20s up Internal air pressure regulated The air pressure regulator knob regulates internal air pressure on the air pressure ...

Page 7: ...otherwise you spend more see the fig 3 3 Insert the power plug foot switch plug and hose plug into the concerned sockets Operation 1 Turn the unit on and indicator at On position lights up 2 Pull the air pressure regulator knob outward and turn clockwise until the desired air pressure is indicated 3 Depending on your needs switch on the MAN or AUTO mode then it is ready to be operated ...

Page 8: ...er to shot easily 6 In AUTO mode the suck back air force should be adjusted under air pressure dispensing cycle and drop size Too strong air pressure will break the normal work 7 When ending work clean the barrel in time and put the concerned parts in cleaning water for 5 10 minutes it is easy to clean Maintenance To assure trouble free operation the following points should be followed 1 Make cert...

Page 9: ...Controller Electrical Schematic Symbol Description F1 0 25A Fuse 0 25am P1 Power board P2 Time set board S1 Solenoid valve W1 Time set potentionemeter SW1 Power switch SW2 Foot switch SW3 Mode switch TR1 Transformer ...

Page 10: ...10 Dispensing Controller Pneumatic System ...