User Manual
BUILT-IN GAS STOVE |
GENOVA 90
16
label containing that information on the appliance.
How to convert a gas source
Adjustment of the reduced valve flow
Burners
Flame
Converting the
hob from LPG
to natural gas
Converting the
hob from natural gas
Gas to LPG
Regular burners
Full flame
Replace the burner
Nozzle according
To the guidelines in
table 1
Replace the burner
Nozzle according
to the guidelines in
table 1
Saving flame
Loosen the adjustment
Spindle (
see fig.7 below
)
And adjust the flame
Loosen the adjustment
Spindle (
see fig.7 below
)
And adjust the flame
Valve adjustment
Valve adjustment should be done with the control knob set at Burner ON saving flame position.
Remove the knob, and adjust the flame with a tiny screwdriver (see fig.7 below).
Fig.7
To check the adjusted flame: heat the burner at full open position for 10 minutes. Then turn the
knob into the saving setting. The flame should not extinguish nor move to the nozzle. If it
extinguish or moves to the nozzle, readjust the valves.
Flame selection
As the burners are adjusted correctly, the flame should be light blue, and the inner flame
should be clear. The size of flame depends on the position of the related control knob.