User Manual
BULIT
– IN GAS STOVE |
LIVORNO 76
Professionale
7
The brown colored high voltage cable (connected to the "Terminal" of the terminal box) must
always be connected to the direct cable of the mains.
In all cases, the power cord must be placed so that a temperature of 50 ° above room
temperature is not reached.
See illustration. The cable is guided by means of fixed band clamps to one side of the box, in
order to avoid any contact with the apparatus below the hob.
REPLACE POWER SUPPLY CABLE
If the cable has to be replaced, only cables of type H05RR-F or H05RN-F must be used for
charging and operating the temperature. In addition, the yellow / green ground wire should be
about 2cm longer than phase and neutral wires.
ADAPTING DIFFERENT TYPES OF GAS
Change of nozzles
1) Remove the pan support.
2) Remove burner covers and burner flames.
3) Use a size 7 screwdriver to remove the nozzles and replace them with the type that
corresponds to the gas used (see table).
4) Re-assemble the parts, following the same instructions given to the reverse.
5) Then replace the data (near the gas connection source) with the new gas type information.
If the pressure of the used gas is different from the one specified or its variable, a gas pressure
regulator must be installed that complies with the standards for the supply pipe.
MINIMUM LEVEL ADJUSTMENT
1) Turn on the burner as indicated.
2) Turn the faucet to the minimum flame position.
3) Remove control knobs.
4) Use a thin screwdriver to turn the bypass pin located near the faucet bar. (See Figure B).
For LPG gas, turn the bypass pin fully clockwise.
The result should be a small, but homogeneous flame which is uniform around the
surroundings of the burner ring. For the triple-A version see Fig. A. bypass 1 central burner,
bypass 2 both burners.
5) Finally, make sure that the burners are not turned off when the faucet is turned quickly from
the maximum to the minimum position.