User Manual
BUILT-IN GAS STOVE |
LIVORNO 76
9
5. INSTALLATION
The following instructions are addressed to the qualified installer, so installation and
maintenance procedures can be followed in the most professional and expert manner.
Important: Unplug the electrical connection before performing any maintenance or
regular maintenance.
Positioning for gas hob
Important:
this unit can be installed and used only in rooms with permanent ventilation.
The following requirements must be met:
a) The room must be equipped with a ventilation system that ventilates smoke and
combustion gases outside the rooms. This should be done by hood or electric fan.
In a fireplace or fireplace Directly outside
branched.
(exclusively for kitchen appliances)
b) Air must be allowed for adequate combustion. The air flow for combustion purposes
must not be less than 2 m³ / h per kW of installed capacity. The air supply will be
effected by the inflow from the outside through a duct, its internal cross section is at
least 100 cm² and should not be accidentally blocked.
The gas plate without safety devices, to prevent the flame from accidentally going out,
must have ventilation that operates in two volumes. For example, a minimum of 200 cm²
(Fig. 3). Otherwise, the room can be indirectly ventilated through adjacent rooms that
are equipped with outside ventilation ducts. Although the adjacent rooms are not shared
areas, the rooms, but the risk of fire is hidden (Fig. 4).
Summary of Contents for LIVORNO 76
Page 1: ......